![7th Sense DeltaServer Скачать руководство пользователя страница 55](http://html.mh-extra.com/html/7th-sense/deltaserver/deltaserver_user-manual_3044853055.webp)
55
MC258-2 Device Control with DeltaServer : User Guide
© 2023 7thSense
DeltaShowControlInterface
DI 3 (pulsed)
= load sequence “digitalinput_b3_s1” (on)
= load sequence “digitalinput_b3_s0” (off)
DI 4 (pulsed)
= load sequence “digitalinput_b4_s1” (on)
= load sequence “digitalinput_b4_s0” (off)
DI 5 (pulsed)
= load sequence “digitalinput_b5_s1” (on)
= load sequence “digitalinput_b5_s0” (off)
Appendix: Sending ASCII to ADAM-6060
It is also possible to send an ASCII UDP command to an Advantech ADAM-6060 to address a relay
output.
This is not part of DeltaShowControlInterface.
A typical string would be:
SENDASCIIUDP [IP_Address] [Port] [ASCII_Command]\x0D
Example:
SENDASCIIUDP 10.100.101.179 1025
#01
10
01
\x0D
#01
identifies that we are addressing an ADAM-6000 series device.
10
is which of the 6 channels (relay outputs) to address: the first digit should always be 1, the second
digit is the channel 0-5 (base 0), so ‘channel 4’ is
13
.
01
is the on/off trigger: 00 = Off; 01 = On
\x0D is the carriage return to send the command
Document Information
Date
Document
edition
Software
version
Revision Details
Author/Editor
July 2017
1
Delta 2.5 and above
New release
Andie Davidson
July 2020
2
Delta 2.5 and above
Revised server terminology
Andie Davidson
Содержание DeltaServer