background image

Applicator Overview:

The  device  comes  with  a  set  of  applicators  often  referred  to  as  probes.  The 
double-tipped probes must make direct and constant contact with the skin, as 
both the probes together complete the circuit required for the treatment. The 
two specially designed probes are manipulated over the surface of the skin in a 
precise way to stimulate the different muscles requiring treatment. To enhance 
ease of use, each probe has a separate cable,  which will be connected to the 
output socket. 

The  conductivity  bar  on  the  device's  LCD  screen  will  become  solid  black 
confirming that the microcurrent is conducting evenly through the skin.

7

Содержание MYOLIFT MINI

Страница 1: ...TM MYOLIFT MINI...

Страница 2: ......

Страница 3: ...oLift Mini Training Manual is for Educational and Training purpose only No portion of this manual may be reproduced or transmitted in any form or by any means electronic or mechanical including photoc...

Страница 4: ...ed in this training manual and any tm training classes provided by 7E Wellness and MyoLift Mini are not meant to be used to diagnose or treat any medical condition and are not liable for any reactions...

Страница 5: ...onditions Electrical implanted devices such as a pacemaker Epilepsy History of Seizures Active Cancer Pregnancy Heart Conditions Consult with physician Diabetes Consult with physician Recent Facial Su...

Страница 6: ...inful sensations have been reported during or following electrical stimulation to the head and face Lowering the intensity may reduce or eliminate these sensations There also may be a perception of fl...

Страница 7: ...yoLift Mini Device Applicator Overview tm MyoLift Mini Operations tm MyoLift Mini Treatment 7e Signature Movements tm MyoLift Mini Device Maintenance Troubleshooting Standard Instructions Professional...

Страница 8: ......

Страница 9: ...tive and negative spheres The MyoLift Mini device allows you to adjust the current output from 0 to 400 microamps as per the client comfort level tm For your MyoLift Mini device to operate properly th...

Страница 10: ...py regimen will establish visible results This gentle non aggressive non invasive and progressive treatment results in skin tightening toning and firming In fact the results from microcurrent facial t...

Страница 11: ...ed back to a much more youthful appearance At the same time the microcurrent improves circulation that stimulates production of collagen improves tone and texture and improves or eliminates fine lines...

Страница 12: ...intended for facial stimulation and is indicated for over the counter cosmetic use tm The MyoLift Mini Device Includes The Following MyoLift Mini Device tm Lead Wire Probe Applicators 4oz Conductive G...

Страница 13: ...y Level 2 Educate Key Level 2 Erase Key Time Increase Decrease Key Run Pause Key Level 1 Erase Key Turn it On Off Status Indicator Battery Icon Level 2 Mode Intensity Treatment Time Value Conductivity...

Страница 14: ...ndicator on the top right corner of the device The battery icon becomes steady when the battery is fully charged A fully charged battery will last approximately 30 40 treatments If the device does not...

Страница 15: ...uired for the treatment The two specially designed probes are manipulated over the surface of the skin in a precise way to stimulate the different muscles requiring treatment To enhance ease of use ea...

Страница 16: ...Status Indicator Battery Icon Level 2 Mode Intensity Treatment Time Value Conductivity Bar Indicator Level 1 Mode Press to start Insert probes or lead wire Charging socket tm MyoLift Mini Operations 8...

Страница 17: ...s the device is on and may be paused at any time The timing will also pause and resume when Run is pressed once again tm MyoLift Mini Operation Run Pause Intensity Increase Decrease Educate Level 1 Ed...

Страница 18: ...Level 1 Educate Level 2 Erase Level 2 Time Increase Decrease Run Pause Erase Level 1 tm MyoLift Mini Intensity Range is 0 400uA Level 1 Intensity Range is 0 175uA Level 2 Intensity Range is 350 400uA...

Страница 19: ...utton Intensity Increase Decrease Educate Level 1 Educate Level 2 Erase Level 2 Time Increase Decrease Run Pause Erase Level 1 Pre Caliberated Timing 10 20 minutes Upward Arrow Increases the TIME Down...

Страница 20: ...area Forehead Lips and Thin Skin Preset waveform to help lengthen the muscles Erase Level 1 focuses on skin texture and super cial lines It relaxes the muscles and helps to work on fascia release for...

Страница 21: ...te Level 2 Erase Level 2 Time Increase Decrease Run Pause Erase Level 1 Pre Calibrated to 175 uA This program shortens the muscles Educate Level 1 focuses on toning muscles that are super cial Lifts t...

Страница 22: ...tensity if it feels stinging too strong or brings visible twitching of the muscles This program lengthens the muscles Erase Level 2 focuses on skin texture and reduction in the appearance of wrinkles...

Страница 23: ...ncrease Decrease Run Pause Erase Level 1 Pre Calibrated to 350 uA Decrease the intensity if it feels stinging too strong or brings visible twitching of the muscles This program shortens the muscles Ed...

Страница 24: ...f the body tm Note MyoLift Mini utilizes double tipped probe applicators with a flexible handle designed True microcurrent is delivered with the pinch and hold technique on the different size muscles...

Страница 25: ...tegrity shape and lifted appearance one must understand if the muscles need to be lengthened or shortened and the direction of the movement LENGTHENING Erase Setting Muscles that need to be relaxed ne...

Страница 26: ...on spray state approved disinfectant onto wet paper towel and wipe down the device and probes thoroughly With a second paper towel wet with water only wipe down the device and probes thoroughly Allow...

Страница 27: ...ed Probe applicators are not inserted into the output socket Unplug the device from the power socket and then turn it on Charge the battery for 4 5 hours Make sure that the handheld probe applicators...

Страница 28: ...deliver more microcurrent energy around challenging areas for better results Rule of thumb To deliver the maximum true microcurrent to the area the pinch and hold movement is used with the skin in bet...

Страница 29: ...nd approximate guidelines for frequency of treatment 20 35 years old Preventative can be done once every month 35 40 years old Initial series of 3 6 once per week Maintenance every 6 8 weeks 45 50 yea...

Страница 30: ...tm Turn the 7E MyoLift Mini device ON and press Run Pause button The conductivity bar will start flashing Start with the Erase program based on the area of treatment Increase decrease the intensity a...

Страница 31: ...neral based to maintain a wide range of conductivity The treatment products are infused with essential additives such as minerals vitamins peptide proteins sea kelp and natural ingredients to deliver...

Страница 32: ...conditions and focuses on eliminating the impurities of the skin This gel will drive microcurrent energy into the skin for clarification and self healing of antibacterial properties de congesting decr...

Страница 33: ...ry probe applicator just outside the hairline at the top of the forehead Place the moving probe applicator just over the eyebrow and pull the probe up towards the stationary probe at the top of the fo...

Страница 34: ...1 175 microamps Program Level Intensity Repetition Erase 3x Note Dots Stationary Probe 26...

Страница 35: ...eyebrows do not touch probe applicators together Draw the two probe applicators up and out towards each eyebrow using light pressure and stretching apart any lines Hold for 3 5 seconds and repeat 1 17...

Страница 36: ...bottom probe applicator stationary using light pressure and stretch apart any lines Hold for 3 5 seconds and repeat Perform the move on the other side of the face and repeat so each side is treated tw...

Страница 37: ...e center of the upper lip Simultaneously slide the probe applicators outward toward the corners of the mouth using light pressure and stretch probes apart Hold for 3 5 seconds 1 Program Level Intensit...

Страница 38: ...away moving to the edge of the mouth When you reach the edge of the mouth hold movement for 3 5 seconds Move to a lower position on the chin and repeat the move Repeat movement at least 3x over the en...

Страница 39: ...ds the lip and the other towards the jawline Hold movement for 3 5 seconds Move the probe applicators to a position closer to the end of the mouth and repeat the move Repeat movement at least 3x over...

Страница 40: ...stationary while pulling the top probe applicator up firmly to where it is level with the middle of the mouth Hold for 3 5 seconds and repeat Continue this move on the other side of the chin and repe...

Страница 41: ...el on the selected facial area s being treated tm Turn the 7E MyoLift Mini device ON and press Run Pause button The conductivity bar will start flashing Place the stationary probe just under the ear l...

Страница 42: ...y the 7e Conductive Tx Gel on the area being treated before using the tm 7E MyoLift Mini device Place the stationary probe just under the ear lobe where the jawline and ear meet one end of the Sternoc...

Страница 43: ...u get to the center of neck making sure to avoid working over the trachea area When you reach the jawline hold the movement for 3 5 seconds Program Level Intensity should be Educate1 at 175 microamps...

Страница 44: ...hile the zygomatic minor is for healthy appearance of the face To remove the sagging in the middle of the face Microcurrent treatment is needed to contract tightening up any slackness in the cheek are...

Страница 45: ...2 350 400 microamps Program Level Intensity Repetition Educate 3x Note Dots Stationary Probe 37...

Страница 46: ...uth Push the second probe applicator up towards the first getting under the muscle at the corner of the mouth and lifting to produce a snarl Hold for 3 5 seconds and repeat Continue this move on the o...

Страница 47: ...the second probe applicator up towards the first getting under the muscle at the corner of the mouth and lifting to produce a snarl Hold for 3 5 seconds and repeat Continue this move on the other side...

Страница 48: ...the stationary probe applicators When the moving probe applicator reaches the stationary probe applicator hold movement for 3 5 seconds do not let probe applicators touch Work vertically from side of...

Страница 49: ...n you have the cheek muscle pinched between the two probe applicators and hold for 3 5 seconds Repeat Continue out towards the ear performing each move twice Perform this move on the other side of the...

Страница 50: ...cheek with firm pressure Stop when you have the cheek pinched between the two probe applicator and hold for 3 5 seconds then repeat Continue out towards the edge of the eye performing each move twice...

Страница 51: ...the ear Gently pinch the two probe applicator together hold for 3 5 seconds and repeat Continue up towards the arch of the eyebrow performing each move twice Perform the move on the other side of the...

Страница 52: ...or under the eyebrow and lift up firmly so the brow is arched Continue the move down the eyebrow holding for 3 5 seconds repeating Perform the move on the other side of the face and repeat so each sid...

Страница 53: ...sweep over the eyebrow straddling the eyebrow towards the first probe Stop when the probe applicators are close but not touching Hold for 3 5 seconds and repeat Perform the move on the other side of t...

Страница 54: ...agile The lines can be caused by sunglasses tm eyeglasses migraines and sleeping on stomach The MyoLift Mini Microcurrent device stimulates the muscles around the eye to improve the circulation in the...

Страница 55: ...and next to the nose Start the moving probe applicator at the outside of the eye and gently sweep the probe applicator in towards the first probe applicator Stop when the probe applicators are close b...

Страница 56: ...ich have the serial number removed altered or defaced or rendered illegible During the above one or two year warranty period a product with a defect will be repaired or replaced with a reconditioned c...

Страница 57: ...no charge is made for service Please contact 7E Wellness customer service to request an RMA return form No returns will be accepted without an RMA Have the product insured packed with sufficient prote...

Страница 58: ......

Страница 59: ......

Страница 60: ...Version 01 20...