Содержание Escort i-5

Страница 1: ......

Страница 2: ...2 4 Pairing BLE sensors 13 2 5 Pairing wired sensors no tracker gateway 16 2 6 Pairing wired sensors tracker gateway is used 23 2 7 Tank calibration table for TD BLE 29 2 8 Configuring Indicator s screen 35 2 9 Displaying total average level of several TD sensors 39 2 10 Retransmission of BLE sensors data 43 2 11 Additional features FW update password management 45 3 SERVICE AND SHELF LIFE WARRANT...

Страница 3: ...ion protocol in case there are no other devices that poll the devices connected to the same RS 485 or RS 232 network In other cases the Indicator can be configured to listen the communication between a polling device and polled devices such as wired sensors Escort i 5 can transmit the data it receives from Escort BLE sensors via Bluetooth Low Energy interface to an external device once polled via ...

Страница 4: ...ing frequencies GHz 2 402 2 480 Max sensors 10 Max LLS network addresses 40 Max number of lines per tank calibration table 50 Max fuel liquid level in any measurement units 99999 Ingress protection marking in accordance with ГОСТ State Standard 14254 IP65 Electric shock resistance rating in accordance with ГОСТ State Standard 12 2 007 0 Class III Operating conditions min and max ambient temperatur...

Страница 5: ...ESCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 5 of 53 1 3 Escort i 5 design Figure 1 demonstrates the design if the Escort i 5 indicator Fig 1 Escort i 5 design ...

Страница 6: ... indicator Escort i 5 User Manual ТЕМГ 468389 001 1 Digital indicator Escort i 5 Datasheet 468389 001 ПС 1 To be specified while ordering Installation kit ТЕМГ 416931 011 1 Packaging ТЕМГ 465966 001 1 1 5 Packaging The Indicator i 5 along with its passport and installation kit is packaged in a semi rigid corrugated board box The installation kit is packaged in ZIP bags Fig 2 Example of the i 5 ins...

Страница 7: ... the Device it is required to check the presence of all items of the installation kit in the package as well as to examine the Devices for any signs of damage 2 1 5 DO NOT USE THE DEVICE UNDER THE OPERATING CONDITIONS DIFFERENT FROM THE STATED IN THE DATASHEET OF THE DEVICE AND IN THE ART 1 2 OF THE USER MANUAL 2 1 6 AVOID ANY DAMAGE TO THE DIGITAL INDICATOR ESCORT i 5 ITS PARTS OR WIRES DURING TH...

Страница 8: ... 2 How to connect i 5 via app 2 2 1 Make sure that your smartphone supports BLUETOOTH LE BLE 4 0 or higher by checking its documents Enable the geolocation service in the settings of your smartphone 2 2 2 Install and run the Escort Configurator app 2 2 3 On the start screen Fig 5 select Sensor settings then select the model of the Device Fig 6 ...

Страница 9: ...ake sure to give it access to the geolocation service This access is asked for only once This step is obligatory to connect any BLE devices 2 2 5 On the List of available devices screen Fig 7 tap on the required device or search for it by entering the last six digits of the serial number of the device into the search box Fig 8 for example I5_100320 in case of the i 5 ...

Страница 10: ...ESCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 10 of 53 Fig 7 List of available devices Fig 8 Searching by the last 6 digits of the serial number ...

Страница 11: ... IMPORTANT To activate the Escort i 5 and then to detect connect and configure it by means of the app be sure to connect it to a power supply The wiring diagram is shown on the Fig 9 The voltage range is provided in the Table 1 of the present manual Fig 9 Wiring of the i 5 ...

Страница 12: ...reen 2 3 Password 2 3 1 To prevent any attempts to tamper with the settings of the Indicator i 5 by any unauthorized third party the sensor must be protected with a password 2 3 2 When you connect the i 5 for the 1st time and try and change any settings in its configuration you will be required to set up a new password Fig 11 Attention There s no default password on the i 5 The password is set up ...

Страница 13: ...al 2022 08 05 Page 13 of 53 Fig 11 Setting new password Fig 12 Entering a previously set password 2 3 3 After setting the password and whenever you try and change any i 5 s settings you will be required to enter the previously set password Fig 12 ...

Страница 14: ...2022 08 05 Page 14 of 53 2 4 Pairing BLE sensors 2 4 1 To pair any Escort BLE sensor TD DU TH you need to tap Connect sensors Fig 13 2 Then press the button to add a new sensor Fig 14 Fig 13 Connecting sensors 2 Fig 14 Press the button to add sensor ...

Страница 15: ...ber Fig 16 and press the Connect button Both MAC Fig 17 1 and Fig 18 1 and the sensor s serial number Fig 17 2 and Fig 18 2 can be found on its head Or select you can scan the QR code on the sensor s head to pair it with the Indicator To do so press the scan button Fig 15 2 and scan the QR code with your smartphone Fig 15 Connecting BLE sensors Fig 16 Pairing BLE sensor by MAC or name and serial n...

Страница 16: ...SCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 16 of 53 Fig 17 MAC and serial number old design DU BLE used as an example Fig 18 MAC and serial number new design TH BLE used as an example ...

Страница 17: ...he main screen of the Indicator in the app Fig 19 Repeat the procedure to pair more sensors Up to 10 sensors can be paired with the same i 5 2 4 4 Tap on any sensor to open the menu with its settings of current readings Fig 20 Fig 19 Indicator s main screen with several up to 10 sensors connected Fig 20 Sensor menu TD_BLE example ...

Страница 18: ...tracker or gateway to which the sensor s will be connected you need to pair the sensor with the i 5 and then select the Active mode in the mode settings and configure the interval at which the sensor s will be polled will be sent requests for data to 2 5 2 To pair a wired sensor TD DU 180 DGV 200 ALS you need to tap Connect sensors Fig 21 2 Then press the button to add a new sensor Fig 22 Fig 21 C...

Страница 19: ...uest the data from the sensor so that the i 5 could listen to the sensor s response and show its reading the level of the wired sensor will be displayed as 0 Fig 24 2 5 4 The network address of the sensor can be configured in the Escort configurator for PC or in the app Fig 25 and Fig 26 2 5 5 If you need to connect several wired sensors repeat the procedure described above Attention Every sensor ...

Страница 20: ...onfigurator for PC Fig 26 Network address in the app main screen and Settings screen Attention All wired sensors that are not the wired Escort TD sensors such as DU 180 DGV 200 ALS or the wired sensors of other brands that support the LLS data communication protocol will still be treated as the TD sensors ...

Страница 21: ...al 2022 08 05 Page 21 of 53 2 5 6 To make the i 5 send requests for data to the wired sensor s connected to it open the mode settings Fig 27 4 The Passive mode is selected by default Fig 28 Fig 27 Mode settings 4 Fig 28 RS 485 Mode Default setting ...

Страница 22: ...Manual 2022 08 05 Page 22 of 53 2 5 7 Select the Active mode then enter the interval in seconds from 1 to 65 and press Set Fig 29 Then press Save to apply the changes Fig 30 Fig 29 RS 485 Active mode interval setting Fig 30 RS 485 Active Mode ...

Страница 23: ...Active RS 485 mode is selected and the interval is set you will see the readings of your wired sensor s in the app Fig 31 32 if it was connected to the i 5 in accordance with the wiring diagram Fig 33 Fig 31 Wired sensor s data is visible in the app Fig 32 Tap on the sensor to see more data ...

Страница 24: ...ESCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 24 of 53 Fig 33 Wiring diagrams i 5 and wired sensor s RS 485 no tracker gateway ...

Страница 25: ...red sensor or several sensors you need to connect the sensor as shown on the wiring diagram below pair the sensor with the indicator and configure the Indicator i 5 to operate in the RS 485 Passive mode the default mode 2 6 2 To pair a wired sensor TD DU 180 DGV 200 ALS you need to tap Connect sensors Fig 34 2 Then press the button to add a new sensor Fig 35 Fig 34 Connecting sensors 2 Fig 35 Pres...

Страница 26: ...uest the data from the sensor so that the i 5 could listen to the sensor s response and show its reading the level of the wired sensor will be displayed as 0 Fig 37 2 6 4 The network address of the sensor can be configured in the Escort configurator for PC or in the app Fig 38 and Fig 39 2 6 5 If you need to connect several wired sensors repeat the procedure described above Attention Every sensor ...

Страница 27: ...onfigurator for PC Fig 39 Network address in the app main screen and Settings screen Attention All wired sensors that are not the wired Escort TD sensors such as DU 180 DGV 200 ALS or the wired sensors of other brands that support the LLS data communication protocol will still be treated as the TD sensors ...

Страница 28: ...nsor s and the GPS tracker gateway or other compatible device its operating mode must be the Passive one To select it open the mode settings Fig 40 4 The Passive mode is selected by default If it was changed earlier select the Passive mode and press Save to apply change Fig 41 Fig 40 Mode settings 4 Fig 41 RS 485 Mode Default setting ...

Страница 29: ...ted to the tracker and the tracker is receiving the data from it and the Indicator is connected in accordance with the wiring diagram Fig 44 you will see the sensor s readings in the app as well Fig 42 and Fig 43 Fig 42 Wired sensor s data is visible in the app Fig 43 Tap on the sensor to see more data ...

Страница 30: ...ESCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 30 of 53 Fig 44 Wiring diagrams i 5 wired sensor s RS 485 and tracker gateway ...

Страница 31: ...o 1023 or from 1 to 4095 In order to get the Indicator display the liters gallons you need to save a tank calibration table in the i 5 s memory for every TD sensor Attention The table must contain not more than 50 lines 2 7 2 Once the sensor s is paired with the Indicator tap Connect sensors Fig 45 2 and then tap on the sensor to which you need to add the table Fig 46 Fig 45 Connect sensors to acc...

Страница 32: ...configuration and tap Start tank calibration Fig 47 1 Fig 47 Sensor configuration screen Fig 48 Adding table 2 7 4 To import the table from the file select the Import from file option Fig 48 Then find the table you need on your smartphone and select it Fig 49 You can then modify the table should it be necessary Press Save to save the table in the Indicator s memory Fig 50 Repeat the procedure for ...

Страница 33: ...ESCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 33 of 53 Fig 49 Searching table file Fig 50 Table added Press Save ...

Страница 34: ... modify the table if you press any cell Fig 51 Also you can set the Portion in liters or gallons and then add new lines to the table Fig 52 To delete any line press and hold it then swipe to the left and tap Delete Fig 53 Fig 51 Editing cells Fig 52 Changing Portion and adding new lines ...

Страница 35: ...2 add as many portions as you need and edit the level values as per the table you have and need to upload into the Indicator s memory Fig 51 You can delete any line by pressing holding it and swiping to the left and then pressing Delete Be sure to tap Save to save the table and or any changes made to it 2 7 7 To apply the table be sure to activate the Use tank calibration table switcher Fig 54 2 T...

Страница 36: ...ndicator Escort i 5 User Manual 2022 08 05 Page 36 of 53 Fig 54 Enabling tank calibration table 2 and checking the currently saved table Fig 55 Checking the currently saved table swipe downwards to see the whole table ...

Страница 37: ... Window first and in a few seconds the sensor s reading is displayed If you don t press any button the same sensor s data will be on the screen till you press a button Attention You don t need to press the buttons with force Press a button lightly and then let go The buttons react only after you let go If you connect the i 5 for the first time the screen will not show anything unless you pair a se...

Страница 38: ... you need to switch it on in the settings of the Indicator and select the sensor whose data will be displayed in the Window X Fig 57 2 To do so go to the Display settings Fig 56 3 To switch between the Windows 1 10 in the app swipe to left or to the right Fig 56 Display settings 3 Fig 57 Display settings 1 number of the Window and its status 2 Screen mode sensor reading s type selection 3 Window i...

Страница 39: ...e Screen mode menu Then select the sensor whose data must be displayed in the selected Window X in the Sensors menu Fig 59 For any wired sensor select the sensor by its serial number For the BLE sensors select the sensor by its name XX_YYYYYY XX first letters of sensor s model YYYYYY the last 6 digits of sensor s serial number Fig 58 Screen mode data type selected Fig 59 Sensor selection ...

Страница 40: ...ifferent models that transmit the same data type for example Temperature you will also need to select the sensor whose data must be displayed on the Indicator s screen when the corresponding Window is selected by pressing the buttons Fig 60 Screen mode data type selected Fig 61 Same data type by different sensors ...

Страница 41: ...w their average value go to the Display settings Fig 62 3 choose one of the Windows 1 10 in the Display settings menu and select the TD average level in the Screen mode Fig 63 No need to select the sensors in the same menu The level readings of all TD sensor s that are included into the total average calculation will be used to calculate and display their average level Fig 62 Display settings 3 Fi...

Страница 42: ...total value choose one of the Windows 1 10 in the Display settings Fig 64 3 menu and select the TD total level in the Screen mode No need to select the sensors in the same menu The level readings of all TD sensor s that are included into the total average calculation will be used to calculate and display their average level Fig 64 Display settings 3 Fig 65 TD total level option selected for the Wi...

Страница 43: ...sensors Fig 66 2 and tap on the sensor you need Fig 67 Then switch the Include in total average calculation tumbler on Fig 68 3 Attention Be sure to upload and save the tank calibration tables per each sensor as explained in the art 2 7 of the present manual Fig 66 Connect sensors to access the sensor list Fig 67 Tap on the sensor you need Fig 68 Include in total average level calculation 3 ...

Страница 44: ...TD TH DU to an external device GPS tracker gateway other compatible device via the RS 485 interface 2 10 2 To enable the transmission of the BLE sensor s data go to the Connect sensors menu Fig 69 2 then select the sensor whose data you need transmitted to an external device and tap RS settings Fig 74 4 A B Fig 69 A Connect sensors 2 to access the sensor list B then select the sensor Fig 70 Tap RS...

Страница 45: ... and press Save 2 10 3 Select the pair of parameters you need transmitted and switch that pair on Fig 71 Then assign this pair of parameters a network address Fig 72 Attention It is impossible to reuse the network addresses that are already occupied either by a different pair of parameters of the same sensor or a pair of parameters of another BLE or wired sensor ...

Страница 46: ... the RS 485 interface It is possible to use the i 5 in the Passive RS 485 mode so that it could listen to the responses of the wired sensors that they transmit upon receiving requests for data from an external device and respond to the requests sent by the external device with the BLE sensors data the i 5 receives via BLE connection Fig 73 Wiring diagrams i 5 wired sensor s RS 485 and tracker gate...

Страница 47: ...currently established password and then delete it If the password is deleted you can set up a new one Fig 74 Additional features 5 Fig 75 Enter password to establish it or to remove it and then set up a new one 2 11 2 IF you need to update the FW of the Indicator press FW update Fig 76 in the Additional features menu Then confirm your choice The FW file must be downloaded onto your smartphone in a...

Страница 48: ...ESCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 48 of 53 Fig 76 FW update start ...

Страница 49: ...turer In case the repairs were required a new diagnostics deadline can be discussed and agreed upon by the manufacturer and the customer The Device is not subject to obligatory repair or replacement by the manufacturer in case the defect or malfunctioning and or the circumstances that caused the Device s defect or malfunctioning are not covered by the warranty or in case the warranty term had expi...

Страница 50: ...igital indicator Escort i 5 User Manual 2022 08 05 Page 50 of 53 3 6 The manufacturer reserves the right to make changes in the Device s design and in its scope of delivery without prior notice to the customer ...

Страница 51: ...of a vehicle train or an air craft must be executed in accordance with the safety requirements indicated on the packing It is prohibited to toss and or throw the Device when loading or unloading it 4 6 During the transportation it is vital to protect the Device from any exposure to direct sunlight high levels of humidity or ultraviolet radiation to prevent moisture or condensed water accumulating ...

Страница 52: ... Address Description http www fmeter ru download Technical documentations manuals datasheets guides instructions etc firmwares drivers software for the ESCORT brand s products 7 CONTACTS In case of having any questions be sure to contact Escort Tech Support We speak Russian English Spanish and Tatar Manufacturer Techautomatica LLC Russia 420036 Russia Kazan str Dementieva str 2B building 4 www fme...

Страница 53: ...ESCORT Digital indicator Escort i 5 User Manual 2022 08 05 Page 53 of 53 ANNEX 1 Digital indicator Escort i 5 pinout ...

Отзывы: