5.5.2 Configure working mode
Working mode configuration menu
(Figure 5.5.2.1)
[Sessions]
Each serial port of serial device servers can support 1-4 sessions. It means serial port of serial device
server send the received data to Ethernet through socket. More than one of the sessions means serial
port of serial device server sends the received data to Ethernet through more than one socket. Sessions
enable to use by checking the corresponding box.
Basic mode
1
.
TCP Client
As TCP Client side, serial device server will connect forwardly to TCP/IP network equipment, such as PC.
It need to setup to tell serial device server to connect which network address and TCP port number when
conditions is matched. After creating socket, serial device server will sent the data received from each
serial port through socket On the contrary, the data received from socket will be sent to the
corresponding serial port.
TCP Client setting option: [Destination address], [Destination port] and [Connect mode]
The explanation of these setting is as follows
[Local port]
The configuration is the same TCP server, default is 1~65535.
[Destination address]
The IP address or domain name address that device will connect, both of them can correspond the
host computer address on the Internet
[Destination port]
The port that device will be connected, default is 1~65535.
[Connect mode]
Connection mode has 2 types: Immediately and Data trigger
Immediately: When the switches have power supply, it will connect immediately, if connection cut off,