background image

8. 

DIP switch 

9. 

Console Port 

10. 

100 Base-T(X) 

11. 

RS-485/422/232 serial port 

12. 

RS-485/422 serial port 

13. 

Foot pad 

14. 

Wall-mounting location hole 

Mounting Dimension

 

Unit: mm 

 

Model I 

 

Model II 

Note Before Mounting: 

 

Don't place or install the device in area near water or 
moist, keep the relative humidity of the device 
surrounding between 5%~95% without condensation. 

 

Before power on, first confirm the supported power 
supply specification to avoid over-voltage damaging the 
device.

 

 

The device surface temperature is high after running; 
please don't directly contact to avoid scalding. 

Wall-mounted Device Mounting

 

Step 1 

Adopt M3 screw to install the left/right mounting 
board on the device backboard. 

 

Step 2 

Place the device on the wall as reference or 

reference installation dimension; mark 2 bolt 

positions on the wall. 

Step 3 

Nail M4 screws on the wall and keep 2mm 

interspace reserved. 

Step 4 

Hang the device on two screws and slide 

downward, then tighten the screw to enhance 
stability, mounting ends. 

 

Wall-mounted Device Disassembling

 

Step 1 

Device power off. 

Step 2 

Unscrew the screw on the wall about 2mm. 

Step 3 

Lift the device upward slightly; take out the device, 
disassembling ends. 

Note before powering on:

 

 

Power ON operation: First insert the power supply 
terminal block into the device power supply interface, 
and then plug the power supply plug contact and power 
on. 

 

Power OFF operation: first unpin the power plug, then 
remove the power line, please note the operation order 
above. 

Power Supply Connection

 

 

DC power supply 

This device provides 3-Pin 5.08mm pitch 
terminal blocks, in which V+ and V- are DC input, 
FG is the power grounding input; The power 

supply supports non-polarity, power supply range: 12

48VDC. 

Содержание GW1118 Series

Страница 1: ...ble x1 8 Warranty card x1 9 Foot pad x4 If any of these items are damaged or lost please contact our company or dealers we will solve it ASAP Product Overview The series products are MODBUS gateway devices Models are as follows Model I GW1118 8D 3IN1 8 RS 485 422 232 serial ports 2 100M copper port Model II GW1118 8DI RS 485 8 RS 485 422 serial port with isolation 2 100M copper port Panel Design T...

Страница 2: ...ence installation dimension mark 2 bolt positions on the wall Step 3 Nail M4 screws on the wall and keep 2mm interspace reserved Step 4 Hang the device on two screws and slide downward then tighten the screw to enhance stability mounting ends Wall mounted Device Disassembling Step 1 Device power off Step 2 Unscrew the screw on the wall about 2mm Step 3 Lift the device upward slightly take out the ...

Страница 3: ...ing abnormally LINK 1 2 ON Copper port has established an active network connection Blinking Copper port is in a network activity state OFF Copper port has not established an active network connection TX 1 8 OFF No data or abnormal data is being transmitted through serial port Blinking Serial port is transmitting data RX 1 8 OFF Serial port is not receiving data or receiving data abnormally Blinki...

Страница 4: ...Running indicator Copper port connection indicator Serial port transmission and receiving data indicator Power supply Input power supply 12 48VDC Access terminal block 3 pin 5 08mm pitch terminal blocks Power consumption Model I No load 1 80W 12VDC Full load 3 90W 12VDC Model II No load 3 16W 12VDC Full load 3 72W 12VDC Working environment Model I Operating temperature 40 75 Storage temperature 40...

Отзывы: