27
4.3.3
Printer initialization
The printer initialization function is used to format DRAM memory and change the
setting to factory default.
Printer initialization is activated by the following procedures.
1. Turn off the power switch.
2. Hold on the button then turn on the power switch.
3. Release the button when the LED turns blue after 5 purple blinks. (Any blue during
the 5 blinks).
The LED color will be changed as following:
Purple
🡪blue 🡪
red (5 blinks)
🡪 purple (5 blinks) 🡪 blue (5 blinks) 🡪solid blue
Factory default values
:
Parameter
The default value
Speed
127 mm/sec (5
"
) (203DPI)
101 mm/sec (4
"
) (300DPI)
Density
8
Label width
4
“ (
100 mm)
Label height
2.5
"
(63.5mm)
Sensor type
Gap sensor
Gap setting
0.08
"
(2.0mm)
Direction
0
Reference point
0,0 (upper left corner)
Offset
0
Tearing mode
On
Peeling mode
Off
Serial port
Settings
9600 bps, none parity, 8 data bits, 1
stop
Character set
850
Country code
1
Clearing Flash
No
IP address
DHCP