background image

3M Touch Systems, Inc. Proprietary Information -- 29489v05 

 

3M

 MicroTouch

™ 

Controller EX USB 

Reference Guide 

 

For EX111 and EX121 

 
 
 
 
 
 

 

Read and understand all safety information 

contained in this document before using this product. 

3

 

Содержание Touch Screen Controller EX 111

Страница 1: ...ystems Inc Proprietary Information 29489v05 3M MicroTouch Controller EX USB Reference Guide For EX111 and EX121 Read and understand all safety information contained in this document before using this...

Страница 2: ...is not warranted 3M Touch Systems Inc products and software are not specifically designed for use in medical devices as defined by United States federal law 3M Touch Systems Inc products and software...

Страница 3: ...10 Establishing the Data Connection 10 Sensor Connection 11 Mounting the Controller 11 Supplying Power to the Controller 12 Mounting the Sensor 12 Turning On Your System 12 Status Light LED Diagnosti...

Страница 4: ...st 8 24 Controller ID Request 10 25 Controller ID Report 12 25 Read Parameter Request 16 27 Parameter Data Report 4 28 Appendix A EX121 Controller Specifications EX121 Dimensions 29 Technical Specific...

Страница 5: ...supplier in touch systems throughout the world As a 3M Touch Systems customer you are aware that we have strong internal programs that meet or exceed environmental regulations of our customers and th...

Страница 6: ...ciated with improper disposal which if not avoided may result in minor or moderate injury from ground water contamination Dispose of components in accordance with federal state and local regulations T...

Страница 7: ...ur company Whenever you contact Technical Support please provide the following information Touch display size part number and serial number Current driver version Operating system used Information on...

Страница 8: ......

Страница 9: ...rements Power requirements and options Status LED codes Overview of the EX USB Controllers Note For complete specifications for each of these EX USB controllers refer to the appendices at the end of t...

Страница 10: ...otection to 27 kV for ESD discharges to the sensor not to the controller directly that may occur during normal operation of the sensor Refer to the appendices for further specifications Establishing t...

Страница 11: ...row female connector that plugs into the EX111 controller with a right side tail exit The following table describes the pins on this connector Table 3 Sensor Flex Tail Connector for EX111 Controllers...

Страница 12: ...te website at www 3Mtouch com Turning On Your System Before you turn on your custom system ensure that all cables are connected properly and that the controller is properly mounted To start up your sy...

Страница 13: ...1 Firmware EEPROM checksum verification error Reload program code STRAY Error 1 3 2 Unable to initialize stray cancellation Replace controller If error reoccurs might be a sensor problem NOV Error 3...

Страница 14: ...is not formatted when given by the ROM code Installing 3M MicroTouch Software 3M MicroTouch Software includes the driver that enables your sensor to work with your computer 3M Touch Systems has touch...

Страница 15: ...y use these USB commands when writing touch applications developing custom drivers or touch configurations or testing their touch systems Developers can issue commands to initialize the controller sel...

Страница 16: ...for normal mode and 2 for special mode and the vendor ID 0596H to write your own driver The EX USB controller is command set compatible with previous generation MicroTouch USB controllers Modification...

Страница 17: ...y command parameters 6 wLength 2 0xXXXX Number of bytes to transfer The Type field should be set to Vendor 0x10 The Recipient field should be set to Device The Direction field depends on the command R...

Страница 18: ...Pen finger touch status 3 X Compensated 2 0xXXXX Compensated X coordinate 5 Y Compensated 2 0xXXXX Compensated Y coordinate 7 X Raw 2 0xXXXX Raw X coordinate 9 Y Raw 2 0xXXXX Raw Y coordinate The main...

Страница 19: ...bration The calibration can be performed at points inset from the lower left and upper right corners extended calibration or it can be done at those corners This is equivalent to the Calibrate Extende...

Страница 20: ...8 96 The Calibrate Extended command then positions the first calibration target inward from the lower left corner 0 767 and the second calibration target inward from the upper right corner 1023 0 The...

Страница 21: ...essed successfully This would happen if the report length requested by wLength does not match the controller status report size Controller Status Report 6 This report contains information describing t...

Страница 22: ...nue to flash on the LED until the sensor is touched Cmd Status The status for the last command request This field is used to determine whether the last request was processed successfully It is also us...

Страница 23: ...sed to select the type of reset to be performed 1 for Soft Reset and 2 for Hard Reset The wIndex field is not used This field should be set to zero to ensure future compatibility The wLength field is...

Страница 24: ...request to restore the default values in the controller This is used to restore the values to the factory presets A soft reset is automatically done after completing the request so that parameter chan...

Страница 25: ...ure future compatibility The wLength field is set to the size either 18 or 24 bytes of a Controller ID report Response The controller sends the Controller ID report when the request is processed succe...

Страница 26: ...ies it as an EX based USB controller The 1 identifies it as the first model of this type This value is treated as an integer not two characters This means that the 1 will be transmitted first Note If...

Страница 27: ...to return the contents of the requested parameter The byte bRequest is set to 16 to indicate that this is the Read Parameter request The wValue field is set to the number of the parameter being reques...

Страница 28: ...eter Parameter Data Report 4 This report is sent in response to any request for parameter data All parameter data is treated as if it were stored as bytes in the order that it is stored in memory This...

Страница 29: ...splay or enclosed in a molded plastic case 3 75 x 2 5 x 0 9 inches and mounted to the back or side of your display EX121 Dimensions The EX121 has a NOVRAM sensor connector and a USB cable connector an...

Страница 30: ...Touch Systems Inc Proprietary Information 29489v05 The following figures show the overall dimensions of the EX121 controller and the locations of the mounting holes and connectors Figure 1 EX121 Over...

Страница 31: ...and noise Regulatory Requirements CE Compliant Radiated Emissions EN 55022 1998 Class B Compliant AC Mains Conducted Emissions EN 55022 1998 Class B Compliant Telco Lines Conducted Emissions N A N A...

Страница 32: ...ch Resolution Maximum addressable coordinates generated by the controller 16K x 16K ESD Susceptibility1 8 kV Contact Discharge Class 2 per section 9 of IEC 61000 4 2 1 false touch allowed Compliant 27...

Страница 33: ...is controller can be internally mounted in your display The following figures show the overall dimensions of the EX111 controller and the locations of the mounting holes and connectors The EX111 has a...

Страница 34: ...nts CE Compliant Radiated Emissions EN 55022 1998 Class B Compliant AC Mains Conducted Emissions EN 55022 1998 Class B Compliant Telco Lines Conducted Emissions N A N A RFI EN 61000 4 3 ENV 50140 Clas...

Страница 35: ...Touch Resolution Maximum addressable coordinates generated by the controller 16K x 16K ESD Susceptibility1 8 kV Contact Discharge Class 2 per section 9 of IEC 61000 4 2 1 false touch allowed Complian...

Страница 36: ...36 3M MicroTouch Controller EX USB Reference Guide 3M Touch Systems Inc Proprietary Information 29489v05 Figure 4 Storage and Operating Temperature with Humidity Conditions...

Отзывы: