background image

CE:PMR

11003072169       FP3694    Rev

.  a

Quick reference guide

Key 

Function

MODE  

Switches the Lite-Com Pro II on and off.

  

Choose between the functions in the menu. 

UP (+)  

Increases the level of the selected function.

DOWN (–)  

Decreases the level of the selected function.

PTT  

Transmits with the Lite-Com Pro II.

E)

Attenuation (with head band)

Frequency (Hz)

125

250

500

1000

2000

4000

8000

H

M

L

SNR

Mean attenuation (dB) 

14.7

23.4

30.7

34.6

34.5

36.9

37.3

St. dev. (dB)

3.9

4.6

3.2

3.4

3.1

2.7

4.2

33 dB

27 dB

19 dB

30 dB

APValue (84%)

10.8

18.8

27.4

31.2

31.4

34.2

33.1

 

 

Attenuation (with neck band)

Frequency (Hz)

125

250

500

1000

2000

4000

8000

H

M

L

SNR

Mean attenuation (dB) 

15.5

23.3

31.2

35.6

35.0

36.5

40.9

St. dev. (dB)

2.6

2.3

2.0

3.2

3.4

3.4

3.3

33 dB

29 dB

21 dB

31 dB

APValue (84%)

13.0

21.0

29.2

32.4

31.6

33.2

37.6

Attenuation (with helmet attachment)

Frequency (Hz)

125

250

500

1000

2000

4000

8000

H

M

L

SNR

Mean attenuation (dB) 

16.2

22.9

31.7

35.6

34.5

37.7

40.0

St. dev. (dB)

3.2

2.2

2.0

2.9

3.0

3.9

3.3

33 dB

29 dB

21 dB

31 dB

APValue (84%)

13.0

20.7

29.7

32.7

31.5

33.8

36.8

MT53H7F470-50

MT53H7B470-50

MT53H7P3E470-50

403 – 470 MHz

MT7H7F4010-EU-50
MT7H7B4010-EU-50
MT7H7P3E4010-EU-50

Peltor

 Lite-Com

 Pro II

The Sound Solution

Mean attenuation (dB) =

 Average attenuating characteristics at given frequency

St. dev. (dB) =

 Standard deviation at given frequency

APV (dB) =

 Assumed Protection Value. Average attenuating characteristics minus standard deviation at given frequency.

H =

 Average attenuation characteristics in the higher frquency spectrum

M =

 Average attenuation characteristics in the mid range frequency spectrum

L =

 Average attenuation characteristics in the higher frequency spectrum

SNR =

 Single Number Rating

3M Occupational Health &
Environmental Safety Division

3M Svenska AB, Box 2341
SE-331 02 Värnamo
Sweden
Phone: +46 (0) 370 65 65 65
Fax: +46 (0) 370 65 65 99
Email: [email protected]
Internet: www.3M.com/Peltorcomms

© 3M 2012. All rights reserved.
3M™ Peltor™ Lite-Com™ Pro is made in Sweden by
3M Svenska AB, SE-331 02, Värnamo, Sweden.

3M, Peltor and Peltor Lite-Com are trademarks of 3M Corporation,
St. Paul, MN 55144-1000, USA

Please recycle. Printed in Sweden.

Peltor Lite-Com Pro II Product Range

MT7H7F4010-EU-50

 with headband

MT7H7B4010-EU-50

 with neckband

MT7H7P3E4010-EU-50

 with helmet attachment for Peltor G22 and G3000 hardhats. 

(A rear plate is also included for helmet attachments for the Peltor G2000 hardhat.)

Technical Data

Frequency range:  
Operation mode:  

Simplex

Channels:    

Max. 30

Channel raster:  
Channel separation:  
Modulation:   

 (FM)

     

 

FM (16K0F3E / 8K50F3E)

Microphone type:  

Electret (MT53) or dynamic (MT7)

Receiver sensibility:  

Typical -122 dBm

Selective squelch: 

Programmable (and supports CTCSS and DCS)

Output power:  

200 / 20 / 10 mW ERP

Range:  

 

Outdoors up to 3 km depending on conditions

Power consumption:  

Stand-by: ca 55 mA 

     

 

Receiving: ca 65 mA

Transmission:  
Low power:    

ca 100 mA

Medium power:  

ca 115 mA

High power:   

ca 200 mA

Operating time at conditions
10/10/80 TX/RX/Standby at 20°C:  

Hi output power: 

ca 14 hours

     

 

Mid output power:  

ca 16 hours

     

 

Low output power: 

ca 17 hours

Operating temperature:  

-20°C to +55°C

Storage temperature:  

-40°C to +55°C        

Weights including ACK08 battery: 

MT7H7F4010-**-50:  

540 g

     

 

MT7H7B4010-**-50: 

500 g

     

 

MT7H7P3E4010-**-50:  540 g

ACK08 technical information

Charging time:  

approx. 10-12 hours (no visible charging indicators for ACK08)

Capacity:    

3,7 V, 1350 mA, 5 Wh

Charging cable:  

AL2AH (fused 200mA)

After charging cycle is finished charger automatically turns into maintenance charging mode.
ACK08 must be charged with AL2AH connected to a certified 5V SELV power supply such as 3M, Peltor battery charger 
FR08. Power supply must be able to deliver a minimum of 200 mA.

FCC:462.5625MHz~467.7125MHz,

FCC/IC: 12.5 kHz CE: 12.5 kHz/ 25 kHz
FCC/IC: 2.5 kHz

CE: 2.5 kHz/ 5kHz

406.1 - 430,440 - 470MHz,L

PD

:433.05 - 434.79 MHz

(Note:LPD only used in Europe)

Содержание MT7H7B4010-EU-50

Страница 1: ...5 65 65 Fax 46 0 370 65 65 99 Email peltorcommunications mmm com Internet www 3M com Peltorcomms 3M 2012 All rights reserved 3M Peltor Lite Com Pro is made in Sweden by 3M Svenska AB SE 331 02 Värnamo Sweden 3M Peltor and Peltor Lite Com are trademarks of 3M Corporation St Paul MN 55144 1000 USA Please recycle Printed in Sweden Peltor Lite Com Pro II Product Range MT7H7F4010 EU 50 with headband MT...

Страница 2: ...127 3 26 162 2 33 210 7 6 82 5 13 103 5 20 131 8 27 167 9 34 218 1 7 85 4 14 107 2 21 136 5 28 173 8 35 225 7 DCS Digitally Coded Squelch 39 023 53 114 67 174 81 315 95 445 109 631 40 025 54 115 68 205 82 331 96 464 110 632 41 026 55 116 69 223 83 343 97 465 111 654 42 031 56 125 70 226 84 346 98 466 112 662 43 032 57 131 71 243 85 351 99 503 113 664 44 043 58 132 72 244 86 364 100 506 114 703 45 ...

Страница 3: ...te Com Pro II GB IE ZA AE AU NZ 2 11 FR CH BE DE CH AT IT CH ES NL BE SE DK NO FI PT GR PL HU CZ SK SI IL EE LV LT RO RU BY AZ UA HR BG RS TR KZ Appendix A Declaration of Conformity ATEX Certificate IECEX Certificate ...

Страница 4: ...ttaching visor and rain shield 2 Individually sprung stainless steel headband wires provide an even distribution of pressure around the ears Steel headband wires maintain their resilience better than plastic headbands through a wide range of temperatures 3 Low profile two point fasteners allow easy height adjustment 4 Soft wide foam fluid filled ear cushions with built in pressure relief channels ...

Страница 5: ...ure time should be reduced accordingly to protect damaging your hearing VOLUME Use the UP and DOWN buttons to set the incoming volume from the built in communication radio A voice message confirms the new setting each time you press the button There are normally 5 volume steps and an off mode To access off mode press and hold the DOWN button for two seconds when at the lowest volume A voice messag...

Страница 6: ...ecommend where possible NOTICE The operating time depends to a great extent on the condition of the ACK08 and how the Lite Com Pro II is used PTT Push to talk Press PTT to transmit manually using the Lite Com Pro II radio Notes 1 Switch voice control VOX on and off by pressing the button briefly twice A voice message VOX on or VOX off confirms the setting 2 The Lite Com Pro II has BCLO and BTLO bu...

Страница 7: ... to replace the batteries The unit switches off automatically after a few minutes Never replace or install batteries with the unit switched on Before switching on make sure that the batteries are inserted correctly As with any hearing protector incorrect use or failure to the instructions supplied with this product could result in permanent disability due to exposure to noise APPROVALS MT7H7F4010 ...

Страница 8: ...kage M60 2 Wind shield for ambient microphones Effective protection from wind noise One pair per package MT90 02 Throat microphone Dynamic laryngophone for use with Lite Com Pro II MT90 06 Throat microphone Electret laryngophone for use with Lite Com Pro II Notice The following accessories can be used but MUST NOT be connected or disconnected in a potentially explosive environment MT53N 12 Electre...

Страница 9: ...DECT and mobile telephones FL6BT Connecting cable With 3 5 mm mono connector for use with a communication radio FL6BS Connecting cable With 2 5 mm mono connector for use with a communication radio FL6BR Connecting cable With Peltor J11 connector type Nexus TP 120 for use with a Peltor adapter and an external communication radio Contact your Authorised Peltor Lite Com Pro II dealer for information ...

Страница 10: ...8 DOC ...

Страница 11: ...9 ATEX Certificate IECEX Certificate please see lateste version at www iecex com ...

Страница 12: ...10 IECEX Certificate IECEX Certificate please see latest version at www iecex com ...

Страница 13: ...oatia 3M Croatia Representation Office Predstavništvo Žitnjak bbHRA 10000 Zagreb 385 1 2499 750 Czech Republic 3M Česko spol s r o V Parku 2343 24 140 00 Praha 4 420 261 380 111 Denmark 3M a s Fabriksparken 15 DK 2600 Glostrup 45 43480100 Egypt 3M Egypt Sofitel Tower Corniche el Nil St 19th Floor Maadi Cairo 2 02 2525 9007 Estonia 3M Eesti filial Mustamäe tee 410621 Tallinn 372 6 115 900 Finland S...

Страница 14: ...ישראל הרצליה 2042 ד ת 91 Poland 3M Poland Sp z o o Aleja Katowicka 117 05 830 Nadarzyn Kajetany K Warszawy 48 22 739 60 00 Portugal 3M Portugal Lda Rua do Conde de Redondo 98 1169 009 Lisboa 351 21 313 45 00 Romania 3M România Bucharest Business Park Str Menuetului 12 Cladirea D et 3 013713 Bucharest 40 21 202 8000 Russia RUZAO 3M Russia Krylatsky Hills Business Park Krylatskaya st 17 bldg 3 12161...

Страница 15: ...egulated by the FCC the responsible party must obtain a license a written authorization from the FCC for a GMRS system FCC Radiation Exposure Statement This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment This transmitter must not be co located or operating in conjunction with any other antenna or transmitter IC Warning This device complies with Indu...