background image

1-1

SECTION 1: BEFORE INSTALLATION

Inspecting And Handling Your Filter:

Inspect the equipment for shipping damage. If damaged, notify the transportation company and request a damage inspection.

Handle the system with care. Damage can occur if dropped or set on sharp, uneven projections on the fl oor. Do not turn the system upside down.

Make Sure Your Water Has Been Thoroughly Tested:

An analysis of your water should be made prior to the selection of your water conditioning equipment. Your dealer will generally perform this service for you, 
and may send a sample to the factory for analysis and recommendations. Enter your below for a permanent record.

IMPORTANT NOTE:

IMPORTANT NOTE:

Hydrogen sulfi de (H

2

S) must be tested for at the well site. For accuracy, the sample must be drawn with the pump RUNNING and the test be completed 

within ONE minute after the sample is drawn.

Analysis Of Your Water

Hardness _____gpg

Iron (Fe)  

_____gpg

Manganese (Mn)  

_____ppm

pH _____

Tannins (Humic Acid)  

_____ppm

Hydrogen Sulfi de (H

2

S)  

_____ppm

Other_______________  

_____

Other_______________  

_____

There are several different fi lter media which can be used in this fi lter. Each is designed to improve a particular aesthetic problem. NONE OF THEM SHOULD 
BE USED TO MAKE NON-POTABLE WATER SAFE TO DRINK. The following descriptions indicate not only what the media is designed to do, but also points out 
their limitations. 

TABLE OF CONTENTS

SECTION

DESCRIPTION

1

BEFORE INSTALLATION

2

INSTALLATION

3

MAINTENANCE

4

TROUBLESHOOTING

5

SPECIFICATIONS AND OPERATING DATA

6

COMPONENTS PARTS LIST

7

LIMITED WARRANTY

Содержание CFS101BWF

Страница 1: ...AND OPERATING INSTRUCTIONS CFS101BWF and CFS201BWF BACKWASH FILTRATION SYSTEMS Installer Please leave this manual with owner operator Owner Operator Please retain for operation and future maintenance...

Страница 2: ......

Страница 3: ...ts Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system To reduce the risk of physical injury Shut off inlet water supp...

Страница 4: ...ties may deteriorate plastic Take care when using pliers or pipe wrenches to tighten plastic fittings as damage may occur if over tightening occurs Do not install in direct sunlight or outdoors Mount...

Страница 5: ......

Страница 6: ...ulfide H2 S must be tested for at the well site For accuracy the sample must be drawn with the pump RUNNING and the test be completed within ONE minute after the sample is drawn Analysis Of Your Water...

Страница 7: ...re tank will indicate high and low system pressure Record your water pressure data below Water Pressure Low _________psi High _________psi 2 The pumping rate of your well pump must be sufficient for s...

Страница 8: ...Do not install systems in areas where ambient temperatures may go above 110 F 43 3 C or below 40 F 4 4 C Facts to Remember While Planning Your Installation 1 All installation procedures MUST conform...

Страница 9: ...ed water lines Pay particular attention to correct orientation of control valve Water flow should match arrow on control valve The Inlet and Outlet of other water treatment equipment products will var...

Страница 10: ...of filter media may be used in this product depending upon the application During installation dust may cause irritation to skin eyes and respiratory tract and may affect lungs Utilize a NIOSH approve...

Страница 11: ...e 2 4 Open Bypass Valve approximately 1 4 of the way to full open Service Position allowing unit to fill slowly This will purge entrapped air in the bed b Once a steady stream of water is flowing to d...

Страница 12: ...desired backwashing schedule Typically these units are backwashed every third day Consult your dealer for their recommendations for your water How To Manually Backwash Your Filter At Any Time Turn the...

Страница 13: ...l valve Dispose of spent media in accordance with federal state and local regulations a Remove control valve by rotating the valve head assembly to the left or counter clockwise Before loading the med...

Страница 14: ...E position Repair or re place if necessary B Internal valve leak 1 Check piston and spacers and seals Replace as neces sary C Distributor not properly seated in control valve 1 Make sure distributor i...

Страница 15: ...17 43 2 18 45 7 Height 50 127 58 147 32 Approximate Shipping Weight lbs kg l media 45 20 57 26 Maximum operating temperature 110 F 43 3 C Electrical requirements 110V 60Hz Operating pressure 20 125 p...

Страница 16: ...ravel Underbed 68696 37 68686 38 NOTE When ordering components always specify model number 5 6 4 3 2 1 Media Options Model Part Description Application Cu Ft Provided A Media A 050P Activated Carbon R...

Страница 17: ...5 3 BACKWASH CONTROL...

Страница 18: ...8706X 1 NPT Bypass Valve Assy incl Ref Items 49 58 60049 18706 10X 1 BSP Bypass Valve Assy incl Ref Items 49 58 26 19170 Motor 110V 60 Hz 18825 Motor 220V 50Hz 27 11384 Motor Mtg Ground Screw 29 19171...

Страница 19: ......

Страница 20: ...cation Inc s exclusive obligation Warranty Period One 1 year on the entire product unit Five 5 years on the media tank only does not include internal component parts Five 5 years on the control valve...

Отзывы: