background image

3M

 Attest

 Auto-reader Connectivity Technical Specifications

3M

 Attest

 Auto-readers are designed to incubate and 

read 3M

 Attest

 Biological Indicators, which are used to 

monitor the efficacy of sterilization processes. Auto-readers 

(Models 390, 390G, 490, and 490H) come supplied with 

an Ethernet cable and have an embedded web server that 

can be accessed via an internet connected PC’s browser  

at the IP address (static or dynamic) configured on the  

Auto-reader. Use of this connectivity feature is optional.  

If connectivity is desired, it is the customer’s responsibility 

to provide an Ethernet jack and connect the Auto-reader to 

it in order to either: 

a)

    use  the  3M

 Attest

 Auto-reader Web App  

Note:

 Use of the Web App does not require the 

installation of any software; or 

b)

  interface with a compatible Sterile Processing  

software system. 

Consult your facility’s IT Network support team to obtain 

any necessary permissions and assistance connecting the 

Auto-reader to the facility network. 

Security

Auto-reader generated data is stored in local flash memory, 

on-board the device, and not on the healthcare facility 

network or hosted servers. The embedded firmware  

does not run an Operating System (OS). When using the  

Auto-reader Web App, the application relies on temporary 

storage in the user’s web browser to save the data in the 

user-populated fields. If configured per the IFU, data is 

transmitted on the healthcare facility’s secure network only 

(i.e., behind the facility firewall). All data is transmitted via 

standard Hypertext Transfer Protocol (http) over Port 80. 

The maximum data transmission rate is 10 Mbps.
 The Auto-reader does not collect, process, store, or 

transmit any Protected Health Information (PHI). 
Users of this device can comply with the requirements of 

IEC 80001-1.

MAC Address:

 Each Auto-reader has a unique Media 

Access Control (MAC) Address. For units manufactured 

after May, 2014, the MAC address is presented on the LCD 

Display when the user presses the information button on the 

face of the Autoreader three times. For older units, contact 

3M with the unit's serial number and we will provide the 

MAC Address.

Requirements 

Minimum PC software requirements: 

• Operating System: Windows

®

 7

•  Browsers: Microsoft

®

 Internet Explorer 8 or higher  

(DOM Storage and Scripting should be enabled);  

Google Chrome

 21.0.1180.79 or higher; Mozilla Firefox

®

 

14.0.1 or higher. For full functionality, the use of an 

HTML5 compliant browser with JavaScript enabled is 

recommended.

Ethernet connection:

•  Connection switch/router with auto-negotiation 

capability (to identify the Auto-reader as operating at 10 

Mbps and half-duplex) or configurable as 10 Mbps and 

half-duplex.

Connecting Using a Dynamic IP Address 

If your facility network automatically assigns a Dynamic IP 

address when a new device is connected to the network, 

use the supplied Ethernet cable to connect the Auto-

reader to an Ethernet jack and proceed to the 

Verifying 

Connectivity

 section.  

For further information, contact the 3M Sterilization Tech Line at 800-441-1922, Option 2.