3M 7800 Скачать руководство пользователя страница 1

7800 - Reassembly 

© 3M June 2006.  All rights reserved. 

3M™ Full Facepiece 7800 

 

Reassembly 

 

 
Now we will review reassembly and replacement of the 3M™ Full Facepiece 
7800

 

1)  If the 7886 DIN Connector must be replaced, contact 3M Technical 

Service at 1-800-243-4630. 

 

2)  To replace the Inhalation Valve: 

 

a.  Install new valves onto the posts inside the DIN Connector on the 

facepiece. 

 
b.  Be certain the valves are fully engaged under all 3 lugs on the post, 

lay flat and spin on the post. 

 

3)  To replace the 7916 Breathing Room

 

 

a.  Insert the breathing room into the front opening in the faceseal until 

it is flush around the perimeter of the breathing room. 

 

4)  To replace the 7914 Band Clamp: 

 

a.  Place the clamp on the faceseal, holding the breathing room. 
 
b.  Tighten the screw on the clamp with a Phillips head screwdriver. 

 

5)  To replace the 7895 Speaking Diaphragm

 

 

a.  Push the diaphragm into the opening of the breathing room from 

inside the facepiece. 

 
b.  Use the diaphragm removal tool to turn the retaining ring clockwise. 

 

c.  Ensure the grill pattern with deep indentation in the center is visible 

from the inside of the respirator. 

 

6)  To replace the 7999 Air Inlet Gasket: 

 

a.  Position the gasket so the small cut out on the gasket is pointing 

toward the lens. 

 

b.  Push the gasket groove onto the plastic bar and seat the gasket. 

Содержание 7800

Страница 1: ...nt opening in the faceseal until it is flush around the perimeter of the breathing room 4 To replace the 7914 Band Clamp a Place the clamp on the faceseal holding the breathing room b Tighten the screw on the clamp with a Phillips head screwdriver 5 To replace the 7895 Speaking Diaphragm a Push the diaphragm into the opening of the breathing room from inside the facepiece b Use the diaphragm remov...

Страница 2: ...t 11 To replace the 701 Bayonet Adapters when the facepiece is set up for the dual airline supplied air system a Insert the adapters into the side air inlets b Turn clockwise until tight c If you are installing new gaskets on the 701 Adapters be certain that they are in the proper position under all 3 bayonet lugs 12 To replace the 7884 Lens a First align the center of the lens with the centerline...

Страница 3: ...the head harness buckle over the faceseal post c Slide the buckle downward to engage it d To ensure proper fit make sure all of the buckles are attached firmly 17 To replace the 7894 Standard Eyeglass Frame a Insert the two prongs of the eyeglass frame into the holes of the frame holder with the prongs directed away from the bow of the frame holder b The eyeglass frame and the bow of the frame hol...

Страница 4: ...7800 Reassembly 3M June 2006 All rights reserved 18 To replace the shrouds a Pull the shroud onto the facepiece such that the side ports DIN and lens are positioned in the proper openings on the shroud ...

Отзывы: