background image

3M

™ 

Wire Insertion Tool, 3430-1000

Instructions

General

All the 3M

 IDC Connectors, with the exception of the D-subminiature and CHG connectors, can be terminated to discrete 

wire by using the Wire Insertion Tool, 3430-1000. For connectors terminated to round flat cable, 3M

 Locator Plates and 

Presses are recommended.

Assembly

1.  Position the conductor over the “U” contact. (Figure 1)

Figure 1

2.   Visually line the deeper grooves of the wire insertion tool 

parallel to the contact. (Figure 2)

Figure 2

3.   Holding the tool perpendicular to the contact, push the tool 

down fully seating the wire within the contact.

4.   Excessive conductor lengths can be trimmed with a sharp 

blade against the connector surface. (Figure 3)

Figure 3

5.   For protective cover – remove the paper liner, align the 

cover latches with the body slots and push cover down 
firmly until the cover latches are in place. (Figure 4)

Figure 4

Отзывы: