13
Installation and Set-Up
(Continued)
BOX SIZE CAPACITY OF CASE SEALER
At its factory setting, the case sealer handles
box sizes up to 570 mm [22.38 in] maximum
height. If larger capacity is needed, the machine
can be adjusted to accommodate boxes up to
670 mm [26.38 in] high. Refer to page 28,
"Special Set-Up Procedures – Box Height Range",
for set-up procedure.
Note – Adjusting machine to accommodate
670 mm [26.38 in] high boxes also increases
minimum box size to 170 mm [6.75 in].
Note – Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems,
or other electrical requirements compatible
with local practice.
ELECTRICAL CONNECTION
The electrical control box (mounted on the lower
right side of the machine frame) contains the pre-
set circuit breaker. The box can be relocated to
the other side of the machine if desired. A
standard three conductor power cord with plug is
provided at the back of the electrical control box
for 115 Volt, 60 Hz, 2.8 Amp electrical service.
The receptacle providing this service shall be
properly grounded. Before the power cord is
INITIAL START-UP OF CASE SEALER
After completing the "Installation and Set-Up"
procedure, continue through "Operation" for
tape loading and start-up to be sure case sealer
is properly adjusted to run boxes.
Figure 2-3 – Machine Bed Height Adjustment and Lower Tape Drum Bracket Position
TAPE LEG LENGTH
Taping heads are pre-set to apply 50 mm [2 in]
long tape legs. To change tape legs to 70 mm
[2.75 in], see "Special Set-Up Procedures",
page 28.
WARNING – To prevent shock and
fire hazard: Position extension cord
where it will be out of the way of foot or
vehicle traffic. Extension cord is only for
temporary use – do not use for a
permanent installation.
plugged into 115 Volt, 60 Hz outlet, make sure
that all packaging materials and tools are
removed from the machine. Do not plug
electrical cord into outlet until ready to run
machine.
Use of an extension cord is not recommended.
However, if one is needed for temporary use, it
must have a wire size of 1.5 mm diameter
[AWG 16], have a maximum length of 30.5 m
[100 ft], and must be properly grounded.
Содержание 29600
Страница 2: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 12: ...6 THIS PAGE IS BLANK ...
Страница 16: ...10 THIS PAGE IS BLANK ...
Страница 20: ...14 THIS PAGE IS BLANK ...
Страница 26: ...20 THIS PAGE IS BLANK ...
Страница 30: ...24 THIS PAGE IS BLANK ...
Страница 32: ...26 THIS PAGE IS BLANK ...
Страница 35: ...29 Special Set Up Procedure Continued Figure 5 3 Upper Frame Removal ...
Страница 38: ...32 THIS PAGE IS BLANK ...
Страница 43: ...37 800asb Assembly 800asb Adjustable Case Sealer W AccuGlide II STD 1 1 2 Inch Taping Heads ...
Страница 44: ...38 800asb Adjustable Case Sealer Figure 2799 ...
Страница 46: ...40 800asb Adjustable Case Sealer Figure 4790 ...
Страница 48: ...42 800asb Adjustable Case Sealer Figure 4792 ...
Страница 50: ...44 800asb Adjustable Case Sealer Figure 4793 ...
Страница 52: ...46 Figure 4794 800asb Adjustable Case Sealer ...
Страница 54: ...48 800asb Adjustable Case Sealer Figure 4795 ...
Страница 56: ...50 800asb Adjustable Case Sealer Figure 4796 ...
Страница 58: ...52 800asb Adjustable Case Sealer Figure 5213 ...
Страница 60: ...54 800asb Adjustable Case Sealer Figure 5213 ...
Страница 62: ...56 800asb Adjustable Case Sealer Figure 6177 ...
Страница 64: ...58 800asb Adjustable Case Sealer Figure 6183 1 of 2 ...
Страница 66: ...60 800asb Adjustable Case Sealer Figure 6183 2 of 2 ...
Страница 68: ...62 Figure 6184 1 of 2 800asb Adjustable Case Sealer ...
Страница 70: ...64 Figure 6184 2 of 2 800asb Adjustable Case Sealer ...
Страница 72: ...66 800asb Adjustable Case Sealer Figure 6185 1 of 2 ...
Страница 74: ...68 800asb Adjustable Case Sealer Figure 6185 2 of 2 ...
Страница 76: ...70 800asb Adjustable Case Sealer Figure 6186 ...
Страница 78: ...72 800asb Adjustable Case Sealer Safety and Information Labels ...
Страница 80: ...THIS PAGE INTENTIONALLY LEFT BLANK ...