Installation Guide:

AC/DC

Power Adapter

Heron IOS

USB 3.0 Cable

Plug in the two USB dongles

QuantorClinic(Gray) & Exocad(Blue)

Prior to software installation ensure that the following criteria have been met:

• 

The person installing the software has administrative privileges on the PC

• 

The PC has an open USB 3.0 port (i.e. SuperSpeed, blue port)

•  Make sure that apps are allowed to access the camera in 

Settings, Privacy, 

Camera, “Allow apps to access your camera”.

 

Once the system has been carefully unpacked, install the system according to the 

following steps:

Step 1: 

Place the docking station on a flat, stable surface and place the Heron IOS 

hand-piece securely in its docking station

Step 2: 

Connect the AC/DC power adapter cable to the docking station; the 

connector socket is located underneath the docking station

Step 3: 

Connect the provided USB 3.0 cable to the docking station; the connector 

socket is located underneath the docking station

Step 4: 

Connect the other end of the USB 3.0 cable to the computer

Step 5: 

Connect the AC/DC power adapter to a power outlet

Step 6: 

Download and install the QuantorClinic software which is located at the 

following link: 

http://www.3disc.com/support/heron

Connection Guide:

* For PC system requirements please visit http://www.3disc.com/support/heron

** QuantorClinic is 3DISC software that has been bundled with Exocad

Содержание Heron IOS

Страница 1: ...g the Tip 2 Patient Environment 2 Tip Cleaning Sterilization 3 Scanning Step 1 Creating a Case 5 Scanning Step 2 Scanning Preparation 5 Scanning Step 3 Basic Scanning Procedure 6 Scanning Step 4 Final...

Страница 2: ...ng station on a flat stable surface and place the Heron IOS hand piece securely in its docking station Step 2 Connect the AC DC power adapter cable to the docking station the connector socket is locat...

Страница 3: ...ine extending 1 8 meter 6 feet around patient and system Depress bottom button 1 and rotate tip at 90 increments 2 Tip should be locked into position prior to scanning 1 2 1 2 Attach the tip to the ha...

Страница 4: ...following procedure Step 1 Clean the tip with soap water ensuring that the mirror is clean and free of smudges stains or any milky haze Do not use an abrasive surface to clean the mirror Step 2 After...

Страница 5: ...Insert and seal the tip into a sterilization pouch Step 2 Sterilize the wrapped tip in a steam autoclave at a temperature of 132 C 270 F and 210kPa 30 46 psi for 6 minutes 132 C 270 F 210kPa 30 46psi...

Страница 6: ...Click the yellow SCAN icon in top right corner of screen 7 A B E Quantor3D will auto launch taking you to the scan window Scanning Step 2 Scanning Preparation Prepare the patient for the scan by ensur...

Страница 7: ...ns are obtained at a closer range and it is okay if the tip touches the teeth During scanning you should continue to hear a rapid clicking sound and observe a green rectangle indicating the last scann...

Страница 8: ...Rescan any area that is missing critical data for the success of the final restoration Save and proceed to the next step in the scan strategy Scanning Step 5 Exporting Files with Dentalshare STL After...

Страница 9: ...can scanning is a skill that requires practice Prior to use on a patient practice should be conducted using a dental typodont model Lower Upper Jaw Scans 1 Start the scan path on the working arch jaw...

Страница 10: ...g the buccal surface of the posterior teeth and the facial surface of the anterior teeth to complete your scan strategy 5 You can turn the scanner off at any point during the scan make sure you restar...

Страница 11: ...will ring and a green check mark will appear on the upper jaw image in the upper right corner of the application 2 Once the upper jaw is aligned move the handpiece down to the lower jaw Again move th...

Страница 12: ...d do not throw it away The box is optimal for any necessary transportation or shipping of the Heron IOS 3D Imaging and Simulation Corp Americas 22560 Glenn Drive Suite 116 Sterling VA 20164 USA Phone...

Отзывы: