3Disc FireID Скачать руководство пользователя страница 1

User Manual

RFID Reader for FireCR Dental

The

RFID reader supports Direct Connection Mode for a single FireCR Dental

reader with a single computer and Network Sharing Mode for multiple FireCR

Dental readers with multiple computers. This manual describes Network Sharing

Mode using .

Doc No. : TM-501-EN

Rev 0.1.4 Oct. 2013

Part No. : CR-FPM-54-001-EN

3DISC

RFID Reader are trademarks of

3D Imaging & Simulations Corp

, South Korea, and its

affiliates.

All other trademarks are held by their respective owners and are used in an editorial

fashion with no intention of infringement.

The data in this publication are for illustration purposes

only and do not necessarily represent standards or specifications, which must be met by

3D

Imaging & Simulations Corp

.

All information contained herein is intended for guidance

purposes only, and characteristics of the products and services described in this publication can

be changed at any time without notice.

Products and services may not be available in your local

area.

Please contact your local sales representative for availability information.

3D Imaging &

Simulations Corp.

strives to provide as accurate information as possible, but shall not be

responsible for any typographical error.

© Copyright 2013

3D Imaging & Simulations Corp

, all rights reserved, printed, and published

in South Korea by

3D Imaging & Simulations Corp

.

Содержание FireID

Страница 1: ...ta in this publication are for illustration purposes only and do not necessarily represent standards or specifications which must be met by 3D Imaging Simulations Corp All information contained herein...

Страница 2: ...31 2100 Fax 82 42 931 2299 Website www 3DISCimaging com E mail info 3DISCimaging com 3DISC Americas 22560 Glenn Dr Suite 116 Sterling VA 20164 USA Tel 1 703 430 6080 E mail info 3DISCimaging com 3DISC...

Страница 3: ...talled and used in accordance with the instruction may cause harmful interference to radio communication However there is no guarantee that interference will not occur in a particular installation If...

Страница 4: ...GER Damage to the reader can occur if it is used incorrectly If unauthorized changes have been made to the delivered system and accessories the warranty by 3D Imaging Simulations Corp becomes void 3D...

Страница 5: ...The operator should study instructions and precautions carefully before starting to use the device listed here and throughout the manual There are no user serviceable parts inside this device The devi...

Страница 6: ...on and Diagnostic Software 13 Chapter 4 Operation 14 System Specifications 14 Operation Conditions 14 Operating Instructions 15 Chapter 5 Symbols 16 Manufacturer s Declaration 18 Electromagnetic Emiss...

Страница 7: ...of the imaging plate are automatically assigned to the individual patient file Please read and follow the instructions given in this User Manual carefully prior to using the RFID Reader and keep this...

Страница 8: ...uct inspect the shipping container for damage In case the container is damaged notify the shipper immediately Identify the Components Open the shipping container and identify each of these components...

Страница 9: ...D Imaging Simulations Corp representative first 3D Imaging Simulations Corp does not assume any responsibility for damage resulting from disposal of this equipment without consulting 3D imaging Simula...

Страница 10: ...port located on the rear of the 3 Connect the other end of the cable to the USB2 0 port on the computer Figure 3 Mini USB connector on the rear of WARNING Unsuitable Installation Sites Locations with...

Страница 11: ...located and installed automatically if the PC is connected to the internet If internet is not available or the driver installation did not complete normally see Figure 4 the driver for the will need t...

Страница 12: ...1 EN 12 When the driver is installed correctly a USB Serial Converter is added under Universal Serial Bus Controller category and a new USB Serial Port is displayed under Ports category Figure 5 Drive...

Страница 13: ...rd Disk Space Network 100Mbps Ethernet for Network Sharing Mode USB 2 0 HighSpeed Minimum Requirement Operation System Microsoft Windows 7 32 bit or 64 bit CPU Core Duo Core2 Processor Memory RAM 2GB...

Страница 14: ...rature Gradient 0 5 C Min Relative Humidity 15 95 non condensing Storage Temperature 10 C 50 C 14 F 122 F Storage Humidity 15 95 non condensing Storage Atmospheric Pressure 500 1 060 hPa Transportatio...

Страница 15: ...a new PC is added to an existing FireCR Dental reader the PC will download the calibration data from the FireCR Dental reader automatically Figure 6 Typical configuration of Network Sharing Mode Oper...

Страница 16: ...User Manual FireID TM 501 EN 16 Chapter 5 Symbols Symbol Description WARNING Do not pull out the USB cable during tag information reading...

Страница 17: ...Manufacturer Warning Consult Accompanying Documents General mandatory action manual General prohibition indication User Manual Reference Keep Dry Fragile Handle with care This side up Non ionizing el...

Страница 18: ...interference in nearby electronic equipment Manufacturer s Declaration Electromagnetic Immunity The system is intended for use in the electromagnetic environment specified below The customer or the u...

Страница 19: ...ions Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular cordless...

Страница 20: ...cording to the transmitter manufacturer Note 1 At 80 MHz and 800 MHz the separation distance for the higher frequency range applies Note 2 These guidelines may not apply in all situations Electromagne...

Страница 21: ...of the shielded location be verified to assure that they meet the minimum specification a Field strengths from fixed transmitters such as base stations for radio cellular cordless telephones and land...

Страница 22: ...id when the product is used for its intended purpose and does not cover products which have been modified without written permission from 3D Imaging Simulations Corp or which have been damaged by abus...

Страница 23: ...carton is dropped by the shipper there is a good chance that the device will shift within the loose pellet packing and be damaged If the user needs to ship the RFID Reader to another location or back...

Страница 24: ...mpleted form signed by customer to Fax 82 42 931 2299 E mail support 3DISCimaging com Date of Installation Customer Information Hospital Institute Name Address Tel Fax E mail Installer Information Com...

Отзывы: