EVERY 6 MONTHS MAINTENANCE
Clamping filter inspection/replacement
The clamping filter must be inspected once a month, and replaced every 6 months. The clamping filter is located on the
control cabinet .
Part required :
•
Filter element : 1001884R00 .
•
Damp cotton cloth .
Caution: wear PPE (disposable rubber gloves, anti-static coverall, FFP3 respiratory protection, anti-static
safety shoes) .
Caution: make sure the clamping system is not activated .
1 . Remove the cover plate located at the bottom of the control cabinet .
2 .
Inspect the clamping filter :
•
If metal powder is covering large surface of the filter element or is
found at the bottom of the filter guard, then proceed to the next
step .
•
If the inspection does not reveal any presence of powder, then fit
back the cover plate removed previously .
The following steps must be performed if the filter element contains excessive metal powder (see step 2)
or according to the recommended maintenance interval .
3 .
Remove the filter guard from the filter cap by unscrewing it.
4 .
Remove the filter element. Dispose of it in accordance with all local/
regional/national, state and federal regulations .
WARNING : FLAMMABLE POWDERS .
PLACE THE USED FILTER ELEMENT IN A CLOSED METALLIC CONTAINER IN A ROOM WITH FIRE DETECTION .
5 .
Clean the filter guard with the use of a damp cotton cloth.
6 .
Install the new filter element.
7 .
Replace the filter guard.
8 . Fit back the cover plate previously removed .
Cover plate
Filter guard
Filter cap