80
3D SYSTEMS, INC
.
PN:80-D27 Rev.B
EVERY 3 MONTHS MAINTENANCE
The following step-by-step procedures must be performed in the provided order .
Procedure to check the glove for damage .
The gloves must be checked at each use of the machine, or at least every 3 months .
Caution: Dust Hazard .
Machine is equipped with rubber gloves to manipulate inside the manufacturing chamber . If rubber
gloves become damaged, fine dust can blow out into the environment. Do not operate the machine with
damaged glove . If glove ripped or punctured during use, dispose of it immediately, and replace it with
new one .
Gloves are equipped with removable protective sleeves .
1 . Remove the gloves from the machine .
2 . Remove the protective sleeves from the gloves .
3 . Protective sleeves and gloves : check the presence of defects (cracks, splits, holes, cuts) by visual inspection .
4 . Gloves: proceed the following steps:
•
Grasp the glove,
•
Stretch to seal close,
•
Roll up the glove by pressing against body,
•
Listen for leaks .
5 . If glove or protective sleeve damaged, replace them with new one:
•
Protective sleeve reference : 1001958W00
•
Glove reference : 1001892H00