3D SYSTEMS, INC
.
PN:80-D27 Rev.B
2
CONNECTION PANEL : GAS, COMPRESSED AIR, ELECTRICAL POWER SUPPLY
The connection panel is located at the back of the supply cabinet . It contains the following connections:
•
Activation on UPS1 (Emerson)
: the UPS will begin the start-up sequence once power is present . On the LCD, press
either the Up or Down button once, then press the Enter button to turn on the UPS .
•
Turn OFF UPS2 (Eaton)
: press once for 5 seconds on the button "On-Off", then wait a few seconds, UPS screen should
switch off. A message will ask to confirm the turn off, select « yes ».
•
Turn OFF UPS1 (Emerson)
: press "Enter" to enter the setting menu, then select MAIN MENU/3 CONTROL/1 TURN ON
& OFF to enter the TURN ON & OFF screen .
A
B
C
D
E
F
A
GAS SUPPLY : VALVE AND AUTOMATIC COUPLER WITH 6 MM
SPLINED ADAPTOR
B
COMPRESSED AIR SUPPLY : VALVE AND AUTOMATIC COUPLER
WITH 6 MM SPLINED ADAPTOR
C
ELECTRICAL POWER SUPPLY
D
6MM CHAMBER EXHAUST
E
ETHERNET SOCKET : RJ45 NETWORK CABLE
F
MAIN CUT-OFF SWITCH: ON/OFF
I . Airlock
The airlock lets operators load and unload a sintering plate or powder cans, without
disturbing the inert environment in the manufacturing chamber . The maximum capacity
(sintering plate + built part) is 100 kg . The transfer from the manufacturing chamber to
the airlock (and conversely) is automatic .
UPS1 display panel