![3D Systems ProX DMP 200 Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/3d-systems/prox-dmp-200/prox-dmp-200_user-manual_4590842083.webp)
79
3D SYSTEMS, INC
.
PREVENTIVE MAINTENANCE SCHEDULE
Maintenance not listed on this section is only allowed to be performed by 3D Systems-certified Customer Support Engineer.
ITEM
SPECIFICATION
ONCE A
MONTH
EVERY 3
MONTHS
EVERY 6
MONTHS
EVERY YEAR
Air pressure
Check : 5.5 bar
X
Pinch valve pressure
Check : 3.5<X<4 bar
X
Gas pressure
Check : 2 bar
X
Gas flow
Check : 5<X<10 l/min
X
Gloves
Check
X
Front casings
Clean
X
Back casings
Clean
X
Exhaust filter
Replace
X
Chiller
Clean
X
Clamping filter
Inspect
Replace
X
X
Gas filter
Replace
X
Silicon wriper
Replace
X
Chiller filter
Replace
X
Cabinet filter
Replace
X
Cabinets
Clean
X
Calibration
Check
X
3D Systems recommends having an additional annual printer service performed by 3D Systems-certified Customer Support
Engineer. Contact the 3DSystems hotline.
EVERY MONTH MAINTENANCE
The pressure and flowrate controls are performed below the front doors:
A
Compressed air pressure
B
Pinch valve pressure
C
Gas pressure
D
Gas flow
A
C
B
D
Содержание ProX DMP 200