47
3D SYSTEMS, INC
.
PN:80-D48 REV A
•
Airlock door
To access to the airlock door, the front doors must be opened .
The mechanism to open/close the door is a quarter-turn lock system .
•
Airlock positions
The airlock (or sas) is controlled from the screen control panel, as per the following:
OPEN = airlock facing the operator side,
CLOSE = airlock facing the chamber side .
•
Tool required
•
A natural fiber brush for the cleaning process,
•
A 4mm hex key wrench,
•
4 socket head screws (M5x12), to fix the sintering plate on the sintering piston.
1
2
Airlock door closed and
locked.
Airlock door unlocked and
opened.