9
If you choose to mount your station to the wall, It is important to follow these steps to ensure that the station is mounted correctly
and the umbilical is in reach to the material cart without it being stressed.
Required Tools: (not supplied):
Measuring Tape; Pencil for tick mark; Template that is supplied in this guide; #2 Phillips screw
-
driver
•
The Cart Station should be mounted so that a grounded wall 100-240 VAC / 50-60 Hertz, 15 amp receptacle is within reach of
the power cord. Before powering on the station, the grounding terminal connection to earth ground should be verified.
cm (42”)
FLOOR
cm (11”)
Two keyholes
Bottom of station
Two screw holes
11.03”
(280.2 mm)
7.48”
(190 mm)
• Using a 5mm Allen wrench, remove the two M6 screws from the bottom left corner of cart.
• Orient holder as shown and align holder holes to the screw holes at the bottom left corner of station. Install umbilical
holder using the two M6 screws that were removed to secure umbilical holder to the cart station.
•
Using a measuring tape, measure a height of 42” from
the floor and up the wall; add a tick mark on the wall
indicating where the bottom of the station will be.
•
Measure a height of cm (11”) from the tick mark and
up the wall; add another tick mark indicating where the
station’s two mounting keyholes will be.
•
Measure a height of 11.03” (280.2 mm) and the width
of 7.48” (190 mm) from the screw holes center points to
the center point of keyholes. Add tick marks indicating
where the station’s mounting points will be.