5-20
C
HAPTER
5: A
DVANCED
M
ANAGEMENT
Designated Cost
This read-only field shows the
path cost from the Root Bridge to the Designated
Bridge Port for the current port’s segment.
Designated Bridge
This read-only field shows the
Bridge Identifier of the Designated Bridge for the
current port’s segment.
Fwd Transitions
This read-only field shows the
number of times that the current port has transi-
tioned from the Learning state to the Forwarding
state.
Port Enable
Enable / Disable
This field allows you
to enable or disable the current port.
Priority
0 ... 255
This field allows you to specify the
priority of the port. By changing the priority of the
port, you can make it more or less likely to become
the Root Port. The lower the number, the more
likely it is that the port will be the Root Port. The
default setting for this field is 128.
Path Cost
0 ... 65535
This field allows you to spec-
ify the path cost of the port.
The Switch automatically assigns the default path
costs shown in
. If you spec-
ify a new path cost in this field, this automatic
system is disabled, and you can only re-enable it by
initializing the Switch.
Fast Start
Enable / Disable
This field allows you to
specify whether the port goes directly to the For-
warding state when a device is connected to it. Set
this field to Enable if the port is directly connected
to an endstation. The default setting for this field is
Disable.
CAUTION:
If you set the Fast Start field to Enable
when the port is connected to multiple endstations,
loops may occur on your network.
Содержание SuperStack II Switch 3000 10/100
Страница 14: ...1 6 CHAPTER 1 GETTING STARTED Figure 1 2 Increasing port density with the Switch 3000 10 100 ...
Страница 15: ...Unit Overview Front 1 7 Unit Overview Front Figure 1 3 Switch 3000 10 100 front view ...
Страница 17: ...Unit Overview Rear 1 9 Unit Overview Rear Figure 1 4 Switch 3000 10 100 rear view ...
Страница 22: ...1 14 CHAPTER 1 GETTING STARTED ...
Страница 25: ...Configuration Rules with Full Duplex 2 3 Figure 2 1 Fast Ethernet configuration rules ...
Страница 79: ...Virtual LANs VLANs 5 7 Figure 5 5 VLAN configuration with a Switch 3000 10 100 as a basement switch ...
Страница 112: ...6 12 CHAPTER 6 STATUS MONITORING AND STATISTICS ...
Страница 128: ...C 6 APPENDIX C TROUBLE SHOOTING ...
Страница 129: ...D PIN OUTS Null Modem Cable 9 pin to RS 232 25 pin PC AT Serial Cable 9 pin to 9 pin ...
Страница 130: ...D 2 APPENDIX D PIN OUTS Modem Cable 9 pin to RS 232 25 pin RJ45 Pin Assignments ...
Страница 142: ...6 GLOSSARY ...