Configuration Rules with Full Duplex
21
The key topology rules are:
■
Maximum UTP cable length is 100m (328ft) over Category 5 cable.
■
A 412m (1352ft) fiber run is allowed for connecting switch-to-switch,
or endstation-to-switch, using half-duplex 100BASE-FX.
■
A total network span of 325m (1066ft) is allowed in single-repeater
topologies (one hub stack per wiring closet with a fiber run to the
collapsed backbone). For example, a 225m (738ft) fiber link from a
repeater to a router or switch, plus 100m (328ft) UTP run from a
repeater out to the endstations.
Configuration Rules
with Full Duplex
The Switch provides full duplex support for all its ports, including
Expansion Module ports. Full duplex allows packets to be transmitted and
received simultaneously and, in effect, doubles the potential throughput
of a link.
With full duplex, the Ethernet topology rules are the same, but the Fast
Ethernet rules are:
■
Maximum UTP cable length is 100m (328ft) over Category 5 cable.
■
A 2km (6562ft) fiber run is allowed for connecting switch-to-switch,
or endstation-to-switch.
16982ug1.bk Page 21 Thursday, April 29, 1999 4:51 PM
Содержание SuperStack II 3300 FX
Страница 6: ...16982ug1 bk Page 6 Thursday April 29 1999 4 51 PM ...
Страница 22: ...22 CHAPTER 1 INTRODUCING THE SWITCH 3300 FX 16982ug1 bk Page 22 Thursday April 29 1999 4 51 PM ...
Страница 40: ...40 APPENDIX A SAFETY INFORMATION 16982ug1 bk Page 40 Thursday April 29 1999 4 51 PM ...
Страница 44: ...44 APPENDIX B PIN OUTS 16982ug1 bk Page 44 Thursday April 29 1999 4 51 PM ...
Страница 52: ...52 APPENDIX D TECHNICAL SUPPORT 16982ug1 bk Page 52 Thursday April 29 1999 4 51 PM ...
Страница 58: ...58 GLOSSARY 16982ug1 bk Page 58 Thursday April 29 1999 4 51 PM ...
Страница 64: ...16982ug1 bk Page 64 Thursday April 29 1999 4 51 PM ...