The SuperStack

®

 3 Baseline 10/100 Switch is a versatile, 

easy-to-use unmanaged switch. It is ideal for users who want the 
high-speed performance of 10/100 switching but do not need 
sophisticated management capabilities. The Baseline 10/100 
Switch is shipped ready for use. No configuration is necessary.

The Baseline 10/100 Switch has 16 or 24 shielded RJ-45, 
10/100 Mbps auto-negotiating ports on the front panel. Each port 
automatically determines the speed and duplex mode of the 
connected equipment and provides a suitable switched 
connection. Each port also supports automatic MDI/MDI-X 
detection.

The Baseline 10/100 Switch is suited for office use where it can 
be free standing, or rack mounted (in a wiring closet or 
equipment room).

The Baseline 10/100 Switch comes with:

„

One power cord for use with the Baseline 10/100 Switch

„

Four self-adhesive rubber pads

„

One mounting kit

The Switch is powered from the AC mains supply.

The Baseline 10/100 Switch provides high performance switched 
connections to 10 Mbps and 100 Mbps hubs, servers and 
workstations that require a dedicated switched link.

The diagram below shows an sample configuration:

I

NTRODUCTION

Endstations on shared
100Mbps connections

Baseline Dual Speed Hub

100Mbps link

10Mbps link

100Mbps connection
to backbone

Endstations on switched
10Mbps connections

Baseline 10/100 Switch

Endstations on shared
10Mbps connections

Baseline Hub

SuperStack

®

 

3 Baseline 10/100 Switch 16-Port (3C16470) and 24-Port 

(3C16471) User Guide

DUA1647-0AAA01

1

13

12

16 17

20

24

21

4

8 9

5

1

Содержание Baseline 3C16470

Страница 1: ... be free standing or rack mounted in a wiring closet or equipment room The Baseline 10 100 Switch comes with One power cord for use with the Baseline 10 100 Switch Four self adhesive rubber pads One mounting kit The Switch is powered from the AC mains supply The Baseline 10 100 Switch provides high performance switched connections to 10 Mbps and 100 Mbps hubs servers and workstations that require ...

Страница 2: ...o negotiating its speed and duplex mode half duplex or full duplex are automatically determined by the capabilities of the connected device Each port supports automatic MDI MDI X detection and can be connected to either a 10BASE T or a 100BASE TX device The Switch offers priority queuing which means all packets that are received are examined to see if they have been priority encoded If a packet ha...

Страница 3: ...re cannot enter the case of the unit Air flow around the unit and through the vents in the side of the case is not restricted 3Com recommends that you provide a minimum of 25 mm 1 in clearance To prolong the operational life of your units Never stack units more than six high if free standing and ensure that cables are supported so that they do not cause the stack to fall over Do not place objects ...

Страница 4: ...trique Il doit être agréé dans le pays d utilisation Bitte unbedingt vor dem Einbauen des Baseline 10 100 Switch Einheit die folgenden Sicherheitsanweisungen durchlesen WARNUNG Die Installation und der Ausbau des Geräts darf nur durch Fachpersonal erfolgen Wenn die Baseline 10 100 Switch Einheit in einer Stapel mit anderen SuperStack 3 Einheiten eingebaut werden soll muß die Baseline 10 100 Switch...

Страница 5: ...nual activity There may be broadcast storms on the network Remove port connections one at a time waiting a few seconds between each port If the LEDs go off after removing a port connection the device that was connected to that port is introducing an excessive amount of broadcast frames to the network some pieces of network equipment operate by sending out broadcast frames regularly Refer to the do...

Страница 6: ...rnment Printing Office Washington DC 20402 Stock No 004 000 00345 4 In order to meet FCC emissions limits this equipment must be used only with cables which comply with IEEE 802 3 CE Statement Europe This product complies with the European Low Voltage Directive 73 23 EEC and ETIC Directive 89 336 EEC as amended by European Directive 93 68 EEC CSA Statement This Class A digital apparatus meets all ...

Страница 7: ...on to be environmentally friendly in all operations To uphold our policy we are committed to Establishing environmental performance standards that comply with national legislation and regulations Conserving energy materials and natural resources in all operations Reducing the waste generated by all operations Ensuring that all waste conforms to recognized environmental standards Maximizing the rec...

Страница 8: ...tration frontpg pl Documentation Feedback Your suggestions are very important to us They will help make our documentation more useful to you Please e mail comments about this document to 3Com at pddtechpubs_comments 3Com com Please include the following information when commenting the document title part number shown at the bottom of this page and page number if appropriate 8 ...

Отзывы: