Unit Overview — Front
1-11
10BASE-T Ports
The Switch has 12 or 24 10BASE-T RJ45 ports con-
figured as MDIX (cross-over), which provide a full
10Mbps bandwidth to attached endstations. The
maximum segment length is 100m (328ft) over cat-
egory 3, 4, or 5 UTP cable.
As these ports are configured as MDIX (cross-over),
you need to use a cross-over cable to connect to
devices whose ports are MDIX-only. Most of the
10BASE-T ports in 3Com devices are MDIX-only.
100BASE-TX Port
The Switch has a single Fast Ethernet 100BASE-TX
RJ45 port configured as MDIX (cross-over), which
provides a 100Mbps connection to, for example, a
local server. The maximum segment length is 100m
(328ft) over category 5 UTP or STP cable.
As this port is configured as MDIX (cross-over), you
need to use a cross-over cable to connect to devices
whose ports are MDIX-only. Most of the
100BASE-TX ports in 3Com devices are MDIX-only.
LEDs
The table below describes the LED behavior on the
Switch. For more details about corrective action in
the event of a problem, refer to
LED
Color
Indicates
TCVR
Yellow
Port 1 is a Transceiver Module fitted to the
rear of the unit.
Port Status LEDs
Packet
Yellow
Frames are being transmitted/received on the
port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Off
Link is not present.
Plug-in Module Status LEDs
Packet
Yellow
Frames are being transmitted/received on the
Plug-in Module port.
Status
Green
Link is present; port is enabled.
Green flashing
Link is present; port is disabled.
Green flashing
(long on, short
off)
Refer to the “
SuperStack II Switch ATM
OC-3c Module User Guide”
.
Yellow
Plug-in Module has failed its Power On Self
Test (if the MGMT LED is flashing yellow), or
the agent software of the Plug-in Module is
not installed correctly.
Yellow flashing
Plug-in Module is not recognized.
Off
Link is not present or Plug-in Module is not
installed in the Switch.
Unit Status LEDs
Power
Green
Switch is powered-up.
MGMT
Green
Switch is operating normally.
Green flashing
Switch or Plug-in Module is either down-
loading software or initializing (which
includes a Power On Self Test).
Yellow
Switch has failed its Power On Self Test.
Yellow flashing
Plug-in Module has failed its Power On Self
Test.
Содержание 1000
Страница 20: ...1 12 CHAPTER 1 GETTING STARTED Unit Overview Rear Figure 1 5 Switch 1000 rear view...
Страница 24: ...1 16 CHAPTER 1 GETTING STARTED...
Страница 27: ...Configuration Rules with Full Duplex 2 3 Figure 2 1 Fast Ethernet configuration rules...
Страница 104: ...5 30 CHAPTER 5 ADVANCED MANAGEMENT...
Страница 130: ...C 6 APPENDIX C TROUBLE SHOOTING...
Страница 131: ...D PIN OUTS Null Modem Cable 9 pin to RS 232 25 pin PC AT Serial Cable 9 pin to 9 pin...
Страница 144: ...6 GLOSSARY...