© 360 Vision Technology Ltd.
Page 7
Predator Radar Installation Manual V2.1.18.1
4 Connections to Predators with HMA
When the HMA (Hinged Mount Adaptor) is fitted to the Predator, the ‘Predator Composite Cable’ is not used.
Connections between the power supply and Predator use conventional cables as detailed below.
24Vac Power connections between Predator PSU and Predator that is fitted with HMA
Cable Size
No IR
IR75
IR100WL
IR125
0.75mm²
20m
10m
7.5m
7.5m
1.00mm²
25m
12.5m
10m
10m
1.25mm²
30m
15m
12.5m
12.5m
1.50mm²
40m
20m
15m
15m
2.50mm²
65m
30m
25m
25m
3.00mm²
80m
40m
30m
30m
4.00mm²
100m
50m
40m
40m
Ethernet connections between Predator PSU and Predator that is fitted with HMA.
The Ethernet connection uses standard CAT5, CAT5e or CAT6 cables fitted with RJ45 connectors.
RJ45
CAT5, CAT5e, CAT6 Cable
Signal
Pin 1
White with Orange Band
Tx+
Pin 2
Orange
Tx-
Pin 3
White with Green Band
Rx+
Pin 4
Blue
Pin 5
White with Blue Band
Pin 6
Green
Rx-
Pin 7
White with Brown Band
Pin 8
Brown
Gain access to connectors in the HMA
•
Ensure that the fixed part of the HMA is securely bolted to the top of the pole.
•
The hinged part of the HMA (Hinged Mount Adapter) is fastened to the fixed part using three M8x25
long hex head bolts. Use a spanner (13mm) to remove the three bolts. Each bolt is fitted with a
split spring lock washer, a plain metal washer (which prevents the split washer from damaging the
fibre washer) and a fibre washer (which prevents the paint on the hinged part from being damaged
unnecessarily.
•
Open the hinge taking care that the gasket is not damaged and support the weight of the Predator.
Gently open the HMA until the lanyard is able to take the weight. If the lanyard appears to support the
weight of the Predator, there is no need to continue to support the Predator. The connection circuit
board (PCB-000-0222-01) can now be seen.