1 2 3 4 5 6 7 8
CON4
Protocol Settings
3
4
5
6
360 Vision
Off Off Off Off
Pelco D 9600 baud
On
Off Off Off
Pelco D 4800 baud
Off
On
Off Off
Pelco D 2400 baud
On On
Off Off
Pelco P 9600 baud
Off Off
On
Off
Pelco P 4800 baud
On
Off
On
Off
Pelco P 2400 baud
Off
On On
Off
Alarm Settings
7
8
Normal Operation
Off Off
No Pre-alarm, No White Light
On
Off
Forced White Light
Off
On
No Pre-alarm, White Light Timer
On On
CON4 Settings
4.2 Washer Control PCB Setup
Power supplies ordered with a Washer function are shipped pre-built into the PSU weather proof box. The
washer control unit is programmed at manufacture to suit the protocol required and cannot be changed. No
further connections are required to this PCB during installation, but address must be set to suit.
Aux Settings
1
Aux 2 (Pelco default)
Off
Aux 3 (Pelco D 2400 only) On
1 2 3 4 5 6 7 8
CON4
Address (1-7) (Range 1 to 128)
Use Dilswitch to set address same as camera.
Relay Output
Pre-wired CON3 for relay output to washer power PCB.
RS485 In Connections/LK3 termination
Connect RS485 from controller to CON5.
RS485 Out Connections
Pre-wired RS485 to camera from CON6.
Power Connections
Pre-wired 24Vac to CON7.
Inputs
CON1 not used.