background image

5

    DO NOT OVERLOOK

• 

The compact heater is designed for transferring air free of coarse dust, fats, chemical vapours and other pollutants, etc..…

• 

The heater has an IP 20 protection class and can work in an environment with an ambient temperature of +5°C to +40°C.

• 

The suction inlet and the exhaust outlet must not be blocked by anything.

• 

Placing any items on to the body of the heater is not permitted.

• 

The electrical power socket must be located no further than 1.5 m from the heater.

• 

For the heater to operate properly, there must be at least 150mm of free space in front of the suction inlet cover.

3. OPERATING CONDITIONS

5. INSTALLATION

4. TECHNICAL PARAMETERS

2.1 CHECK THE DELIVERY

    

DO NOT OVERLOOK

Check immediately after delivery that the packed product has not been damaged. If the packaging is damaged inform the carrier. 
If the complaint is not lodged in time, no future demands can be claimed.

After unpacking from the box, check whether:
1. The designation on the box corresponds with the rating label on the door heater.
2. The door heater is mechanically damaged.

The electric door heater offers a wide range of applications. Therefore it is possible to install this heater above the door, above the 
store windows and on the wall. For installation, follow the instructions provided below. Due to the fact that this is a heating device, 
basic heating rules should be adhered to. For the calculation of the heating source requirements it is necessary to include the 
heater among the heating sources of the building‘s heating system.

1x

1x

2. UNPACKING

         TECHNICAL INFORMATION

Type

Air power 

[m3/h]

Acoustic pressure 

[dB(A)]**

Voltage / 

Frequency

[V/Hz]

Fan 

current

[A]

Fan power 

input

[W] 

Heater 

power 

[kW]

Total con-

sumption 

[A]

Total power 

input 

[kW]

Increasing air 

temperature 

Δt [°C]

Weight 

[kg]

max 

speed

min 

speed

3m

5m

VCB-A-060-E-

RF-0-0

315

285

46,5

42,1

230 / 50

0,4

57,0

2,4

11

2,5

22,0

6

VCB-A-090-E-

RF-0-0

475

410

48,5

44,0

230 / 50

0,7

87,0

3,1

14

3,2

19,0

8

** Acoustic pressure measured at 3 and 5 m away from the device at maximum motor speed. Direction coefficient Q:2.

Содержание BASIC

Страница 1: ...BASIC P01 0103 0813 01 VCB A 060 E RF 0 0 VCB A 090 E RF 0 0 EN 3 DE 11 PYC 19 CZ 27 ...

Страница 2: ......

Страница 3: ...BASIC VCB A 060 E RF 0 0 VCB A 090 E RF 0 0 EN ...

Страница 4: ...safe to use The harmonised european standards specified in the relevant EC Declaration of conformity were applied in the assessment of this product You will find cur rent and full version of the EC Declaration of conformity on the www 2VV cz website This manual contains important instructions and safety notices To ensure the correct operation and your own safety it is impor tant to carefully read ...

Страница 5: ...check whether 1 The designation on the box corresponds with the rating label on the door heater 2 The door heater is mechanically damaged The electric door heater offers a wide range of applications Therefore it is possible to install this heater above the door above the store windows and on the wall For installation follow the instructions provided below Due to the fact that this is a heating dev...

Страница 6: ...tening elements 4pcs of M8 bolts not sup plied with the product 1 attach the brackets to the wall 2 attach the curtain to the brackets using bolts are supplied with the product detail of the attachment of the heater to the bracket YOU WILL NEED For mounting the bracket use a size 5 hex key DO NOT OVERLOOK Make sure that the exhaust of the heater is not shielded by anything and that the airflow can...

Страница 7: ...possible to connect the heater using an extension cord The maximum bend of the electric power cable is 30mm 6 INSTALLATION 6 3 CONTROL PANEL 152 176 161 190 30 max 30mm Connecting the remote control The remote control does not need to be paired it is already factory set The remote control is powered using 12V battery LR23A batteries are supplied with the product Possibility pair up to 60 devices t...

Страница 8: ...by pressing the button on the remote control Then you can use the speed button to increase or to de crease fan speed Use the button to select whether the heater will be on or off The operation of the fan and the electric heater is indicated by lights on the integrated control panel Turn the device off again using the button When the device is turned off it automatically performs aftercooling of th...

Страница 9: ...Assumed problem Solution The device does not work Interrupted el power supply Check that the el power supply has not been interrupted The remote control doesn t work The curtain is not receiving a control signal from the remote control Check whether the batteries in the controls are flat Check the polarity of the batteries in the remote control Check whether the remote control is too far away from...

Страница 10: ... supplier or the service centre with the following information model number of the air curtain used accessories installation location serial number installation conditions also electrical time of operation a detailed description of the fault 10 2 PUTTING PRODUCTS OUT OF OPERATION DISPOSAL Before disposing of the product make it unusable Old products also contain materials which can be recycled Han...

Отзывы: