background image

GETTING STARTED

To enter the control panel’s System Configuration module to 

program sensor zones and modify settings:

1.

   At Home screen, tap logo in lower-right corner. 

 

Enter

Master Installer Code.

 

Tap

System Configuration

.

Or

2.

   At Home screen:

 

Tap

Security > Menu > Toolbox

 

Enter

Master Installer Code.

 

Tap

:  



 

Installer Toolbox > System Configuration

To navigate through questions and options in the System Configuration 

module:

 Tap 

or

 to scroll between options on the active screen.      

 Tap 

or

to move to the previous or next screen’s question.     

For step-by-step programming information, see the installation 

instructions for the peripheral device or the control panel’s 

Installation and Programming Guide 

from 

dealer.2gig.com

.

Q1 WIRELESS ZONE PROGRAMMING

(Q1) SELECT RF SENSOR # (01 to 48)

Select: 

RF Sensor # (01 to 48)

to select the desired zone option. Then 

tap 

 

Select:  

RF Sensor # Type

to select type. Then tap 

 

Select:  

RF Sensor Equipment Code

to select code (see 

Equipment 

Codes 

on page 4). Then tap 

Enter:    

RF Sensor # Serial Number (7 Digits)

 Enter the serial number or 

place the control panel into learning mode by tapping 

Shift > 

Learn 

and then trip the sensor to transmit its serial number to 

the control panel.

Select:  

RF Sensor # Equipment Age

to select 

(1) New or (2) Existing 

Then tap 

 

Select:  

RF Sensor # Loop Number

to select 

(1) 1

(2) 2

, or 

(3) 3

 

1-

Use Loop 1 for all 2GIG products (except as noted in loops 

below)

 

2-

Thin door/window contact using internal switch

 

3

-Flood/freeze sensors. Then tap

 

Select:   

RF Sensor # Dialer Delay (0 to 1)

until desired option

 

Construct:  

RF Sensor # Voice Descriptor 

Tap 

Insert

. Then tap

to scroll 

the available words or enter the 3-digit code associated with 

the desired word. Tap 

Insert 

again before adding another word. 

There is a five (5) word maximum. See 

Voice Descriptors 

on 

page 4.  Then tap 

 

Select: 

Select RF Sensor # Reports (0 to 1)

to select 

(1) Enabled

 or 

(2) 

Disabled

. Then tap 

  

Select:  

Select RF Sensor # Supervised (0 to 1)

to select 

(1) Enabled

 or 

(2) Disabled

. Then tap 

 

Select: 

Sensor Chime

 

to select chime. Then tap 

 

SUMMARY OF RF SENSOR # SCREEN 

The Summary shows the settings for each sensor. Tap 

Edit Next 

to add the 

next RF sensor, or tap 

Edit Current 

to reconfigure the current RF sensor. Tap 

 Q2 WIRED SENSOR PROGRAMMING

If no wired sensor programming is needed, tap 

Skip

 to go to 

Q3 Key Fob 

Programming

(Q2) ENTER WIRED SENSOR # (1 thru 2)

Select: 

Sensor (Zone) Type

until desired option

 

Select: 

Equipment Age (New/Existing)

until desired option

 

Select: 

Normal State

until desired option

 

 

(0) Not Used, (1) Normally Closed, (2) Normally Open,

 or 

(3) 

Mixed with no EOL

. Then tap 

Select: 

Dialer Delay (Enabled/Disabled)

until desired option

 

Construct:  

RF Sensor # Voice Descriptor 

Tap 

Insert

. Then tap

to scroll the 

available words or enter the 3-digit code associated with the 

desired word. Tap 

Insert 

again before adding another word. 

There is a five (5) word maximum. See 

Voice Descriptors 

on 

page 4.  Then tap 

 

 

Select: 

Sensor Reports (Enabled/Disabled)

until desired option

Select: 

Sensor Chime

until desired option

SUMMARY OF WIRED SENSOR # SCREEN

The Summary shows the settings for each sensor.  Tap 

Edit Next 

to add the 

next wired sensor, or tap 

Edit Current 

to reconfigure the current wired sensor. 

Tap 

Skip 

to move to 

Q3 Keyfob Programming

.  

Q3 KEY FOB PROGRAMMING

If no key fob programming is needed, tap 

Skip

 to go to 

Q4 Keypad Programming

.

(Q3) SELECT FOB # (1 to 8)

Select: 

Fob <#> Used (0 to 1)

to select 

(1) Disabled

 or 

(2) Enabled

. Then tap 

Select: 

Fob <#> Equipment Code 

to select code (see 

Equipment Codes 

on 

page 4). Then tap 

Enter:  

Fob <#> Serial Number (7-Digits) 

Enter the serial number manually (7 

digits) or place the panel into learning mode by tapping 

Shift > Learn 

and then tap the 

Armed Away 

button on the key fob until the LED 

illuminates and the sensor transmits the serial number.

Select: 

Fob # Equipment Age (0 to 1)

to select 

(0) New

 or 

(1) Existing

. Then 

tap 

Select: 

Fob # Emergency Key (0 to 4)

to select 

(0) Disabled, (1) Auxiliary 

Alarm,

 

(2) Audible Alarm, (3) Silent Panic, 

or 

(4) Fire

. Then tap 

Select:  

Fob Can Disarm (Enabled/Disabled)

until desired option

Construct:  

RF Sensor # Voice Descriptor 

Tap 

Insert

. Then tap

to scroll the 

available words or enter the 3-digit code associated with the desired 

word. Tap 

Insert 

again before adding another word. There is a five (5) 

word maximum. See 

Voice Descriptors 

on page 4.  Then tap 

 

Select:  

Fob # Arm No Delay (0 to 1)

to select 

(0) Disabled or (1) Enabled

.  

Then tap 

Select:  

Fob # Key # Output (0 to 2)

to select 

(0) Disabled, (1) Toggle 

Output

, or 

(2) Momentary Output

. Then tap 

SUMMARY OF FOB # SCREEN

The Summary shows the settings for each sensor.  Tap 

Edit Next 

to add the next 

keyfob, or tap 

Edit Current 

to reconfigure the current keyfob. Tap 

Skip 

to move to 

Q4 

Keypad Programming

FIELD PROGRAMMING FOR COMMUNICATION

(Q13) SELECT TWO-WAY VOICE (0 TO 2)

Tap:  

Go To

. Then enter 

13 

to select a two-way voice option.

Select:  

Two-Way Voice (0 to 2)

to select 

(1) Stay On Line

 or 

(2) Stay On Line, 

Including Fire and CO Alarms

. Then tap

 

TO SETUP CELL PRIMARY

(Q8) SELECT DIALER (0 TO 1)

Tap:  

Go To

. Then enter 

08 

to select the dialer.

Select:  

Dialer (0 to 1)

to select

 (0) Disabled

. Then tap

 

Tap:  

Go To

. Then enter 

63 

to select a phone fail detect option.

Select:  

Phone Fail Detect (0 to 1)

to select

 (0) Disabled

. Then tap

TO SETUP POTS PRIMARY

(Q8) SELECT DIALER (0 TO 1)

Tap:  

Go To

. Then enter 

08 

to select the dialer.

Select:  

Dialer (0 to 1)

to select

 (1) Enabled

. Then tap

Tap:  

Go To

. Then enter 

63 

to select phone fail detect.

Select:  

Phone Fail Detect (0 to 1)

to select

 (1) Enabled

. Then tap

Tap:  

Go To

. Then enter 

11 

to enter the CS Phone Number.

Select:  

CS #1 Phone Number (0-25 Digits) 

Enter the phone number. Then tap 

Tap:  

Go To

. Then enter 

12 

to enter the CS Account Number.

Select:  

CS #1 Account Number (4 Digits)

 Enter the account number. Then tap

77-000010-001 Rev D

For technical support in the USA and Canada: 

855-2GIG-TECH (855-244-4832)

 or visit the 

2GIG dealer site at 

dealer.2gig.com

, or email us at 

[email protected]

.

For technical support outside of the USA and Canada, contact your regional distributor.

 

Copyright © 2014 Linear LLC.

Quick Programming Guide

  Control Panel Firmware Version 1.13

Q4 KEYPAD PROGRAMMING 

If no keypad programming is needed, tap 

Skip

 to go to 

Field Programming for 

Communication

.

(Q4) SELECT RF KEYPAD # (1 to 4)

Select:  

Keypad RF Keypad # (1 to 4)

to select desired keypad number. Then 

tap 

Select:  

RF Keypad # Used (0 to 1)

to select 

(0) Disabled 

or 

(1) Enabled

Then tap 

Select:  

RF Keypad # Equipment Code

to select code (see 

Equipment Codes 

on page 4). Then tap 

If using a Wireless Keypad (2GIG-PAD1)

Enter:  

RF Keypad 1 Serial Number (7 Digits) 

Enter the serial number or 

place the control panel into learning mode by tapping 

Shift > Learn 

and then trip the sensor to transmit its serial number to the control 

panel.

If using a Wireless Touch Screen Keypad (2GIG-TS1*)

*

Not available in all 

regions

Select:  

RF Keypad # Keypad ID (Read-Only) 

Tap the 

Learn 

button. Then go to 

the TS1 and tap the 

Pair WIth Panel 

button.  When the learning 

operation succeeds, tap 

OK

 on both the panel and TS1.  

Select:  

RF Keypad 1 Equipment Age (0 to 1)

to select 

(0) New

 or 

(1) 

Existing

. Then tap 

Select:  

RF Keypad # Emergency Keys (0 to 1)

to select 

(0) Disabled 

or 

(1) 

Enabled

. Then tap 

Construct:  

RF Sensor # Voice Descriptor 

Tap 

Insert

. Then tap

to scroll the 

available words or enter the 3-digit code associated with the desired 

word. Tap 

Insert 

again before adding another word. There is a five (5) 

word maximum. See 

Voice Descriptors 

on page 4.  Then tap 

 

SUMMARY OF RF KEYPAD # SCREEN 

The Summary shows the settings for each sensor. 

Edit Next 

to add the next keypad, 

Edit Current 

to reconfigure current keypad. Tap 

Skip 

to move to 

Field Programming 

for Communication

.

Download the 

Control Panel Installation Guide 

from 

dealer.2gig.com.

Содержание pad1

Страница 1: ...ransmits the serial number Select Fob Equipment Age 0 to 1 to select 0 New or 1 Existing Then tap Select Fob Emergency Key 0 to 4 to select 0 Disabled 1 Auxiliary Alarm 2 Audible Alarm 3 Silent Panic or 4 Fire Then tap Select Fob Can Disarm Enabled Disabled until desired option Construct RF Sensor Voice Descriptor Tap Insert Then tap to scroll the available words or enter the 3 digit code associat...

Страница 2: ...STOMER ACCOUNT When creating an account on the Alarm com dealer site enter the serial number for the 2GIG CDMA Cell Radio Module 2GIG GC CDMA 2 VERIFY THE CELL RADIO AND TRANSCEIVER INSTALLATION Ensurethat the2GIG GC CDMA and 2GIG XCVR2 radio are properly installed and connected inside the control panel The firmware version must be v1 10 or higher 3 REGISTER MODULE AND TEST COMMUNICATIONS Power up ...

Страница 3: ...ap Go To Then enter 83 to select a Z Wave door locks feature Select Select Z Wave Feature 0 to 1 to select 0 Degress Farenheit or 1 Degrees Celsius Then tap REMOVING A THERMOSTAT SWITCH OR DOORLOCK Because Z Wave devices are typically programmed into a Z Wave network at the factory during testing most Z Wave devices will need to be removed from that network before you add it to the control panel T...

Страница 4: ...ERCISE 073 EXIT 074 EXIT NOW 075 EXTERIOR 076 EXTERNAL 077 FAILURE 078 FAMILY 079 FAN 080 FIFTEEN 081 FIFTY 082 FIRE 083 FIRE ALERT 084 FIRE DETECTOR 085 FIRST 086 FIVE 087 FLOOD 088 FLOOR 089 FLUID 090 FOIL 091 FOR 092 FORTY 093 FOUR 094 FOURTEEN 095 FOURTH 096 FREEZE 097 FREEZER 098 FRONT 099 FURNACE 100 GAME 101 GARAGE 102 GAS 103 GLASS 104 GLASS BREAK 105 GUEST 106 GUN 107 HALL 108 HALLWAY 109...

Отзывы: