background image

Apartment 

Intercom System

2 EAS

Y

CONTENTS

RF CARD

RF CARD

RF CARD

A

1

2

3

4

5

6
0

7

8

9

*

#

B

RF CARD

A

1

2

3

4

5

6
0

7

8

9

*

#

B

DMR21/S8

DMR21/F2

EP21/F3

EP21/S12

DMR21/D32/F1

DMR21/D16

DMR21/S4/F1

DMR21/D8/F1

DMR21 TECHNICAL MANUAL

Installation Guide.

.........................................................................

2

Modules.

.......................................................................................

4

   Camera Module.

........................................................................

4

   Keypad Module.

.........................................................................

6

   TFT Module.

...............................................................................

11

   Card Reader Module.

.................................................................

12

   Call Button Module .

...................................................................

14

Module Connection.

......................................................................

16

CONFIGURATIONS.

.....................................................................

19

   Common Door Station Setting .

...................................................

19

   Software Update .

........................................................................

20

   Tone Update .

..............................................................................

20

   Namelist Update .

........................................................................

21

       2-wire series 

Содержание DMR21/D16

Страница 1: ...P21 F3 EP21 S12 DMR21 D32 F1 DMR21 D16 DMR21 S4 F1 DMR21 D8 F1 DMR21 TECHNICAL MANUAL Installation Guide 2 Modules 4 Camera Module 4 Keypad Module 6 TFT Module 11 Card Reader Module 12 Call Button Module 14 Module Connection 16 CONFIGURATIONS 19 Common Door Station Setting 19 Software Update 20 Tone Update 20 Namelist Update 21 2 wire series ...

Страница 2: ...contact of the relay NO Normally open contact of the relay EB Exit button positive connection port EB Exit button negative connection port JP LK Electic lock type setting SET DIP switches for door station settings CN KMB Call button module connection port CN T COIL Reserved CN FUN Touch sensor keypad module or TFT display module connection port CN WGN Proximity reader module connection port Bus L1...

Страница 3: ...2 3 4 Cut a hole and install the wall box Final result Use the screws to fasten the panel Connect and plug bus line connector with cable Standard mounting RF CARD OFF ON OFF ON DBC4A A B C D DBC4A A B C D Impedance switch Impedance switch 100 240VAC BUS IM BUS DS PC6 AC OFF ON DBC4A A B C D Impedance switch Code 29 Code 31 Code 30 Code 32 Code 5 Code 7 Code 6 Code 8 Code 1 Code 3 Code 2 Code 4 DMR...

Страница 4: ... 1 2 3 Exit button 12V LK GND LK COM N O EB EB Take off the Jumper JP_LK Cut off the line 1 2 3 Exit button INSTALLATION GUIDE DIP SWITCHES SETTING Totally 6 bits can be configured by dip switch The switches can be modified either before or after installation but restarting the power is needed whenever the switches have been modified Bit 1 and Bit 2 is for door station ID settings When multi door ...

Страница 5: ...le in standby 1 Press Key A the Unlock indicator turns on with the warning sound of BP BP 2 Press and hold Key B to enter the Unlocking Time Delay Setting a warning sound of BP will be heard and the Status indicator blinks one time per second The counting of Unlocking Time is the times that Status indicator blinks the units is second For example the Status indicator blinks for four times that mean...

Страница 6: ...ired You should press confirm button after finish input ting the code number each time otherwise the operation will be cancelled automatically in 10s Setting items Setting range Default value Setting code Reset all settings 1 2 3 4 00 Setting the master code 1 12 digits Valid keys 0 9 1234 01 Setting the key illumination time 10 to 99 seconds continually lit 10 sec 02 Setting the unlock time 01 to...

Страница 7: ...ge 01 99 3 Setting the key illumination time 4 Setting the unlock time 2 Setting the master code Default 1234 Default 10s Default 1s Inputting of new master code ex 4321 1 12 digits Input the setting code Inputting of code Input the setting code 1 Reset all settings 00 1234 4321 01 10 09 Input the setting code 02 Input the setting code 03 If the key illumination time is set to 00 the key illuminat...

Страница 8: ...u set last When the operation tone is set to 0 pressing the digital keypad will sent out a sound of beep When the operation tone is set to 1 pressing the digital keypad will blink one time Cancel all the passwords except the master code Restore the master code to default value 1 2 3 4 When the item is set to 0 press the button to cancel the input and press the button to confirm the input When the ...

Страница 9: ...tton Beep Beep Beep 11 SPK volume adjust setting Input the setting code Input the setting code 11 Inputting of code ex 5 range 0 9 5 Default 4 Unlock via password is still available even when the door station is talking state When door station is talking you can enter the Master code the LED turns white upon that to activate the volume adjusting function Speaker adjustment 3 up 6 down Beep Beep Be...

Страница 10: ... second lock the second lock need external device to support If the password length exceeds 12 digits the system will sent out the sound of beep beep beep beep and the digitals you input before will be cleared at the same time The temporary code can not be set the same as the master code and user code The user code group1 is used to release the first lock and the user code group2 is used to releas...

Страница 11: ...me list Press or to select name After that press to call the corresponding user Press Keypad Module to cancel the call This is the user interface of calling process Know that if the name list is created the resident s name will be showed on screen Press Keypad Module to cancel the call This is the user interface of conversation process The conversation time will be recorded Press Keypad Module to ...

Страница 12: ...ed on TFT screen When registered ID card will be presented to a Proximity Reader Door open message will be showed on TFT Display Module screen This is the user interface of adding card please know that the user interface of delete card or initialization is similar as the following pic ture shows Master Card Setting Power on and short out EB EB a sound of BP will be sent out and the Unlock indicato...

Страница 13: ... on Show the MASTER CARD ADD it will sound BP the Talk indicator and the Unlock indicator will blink and after 10 seconds it will return to standby mode i By PC ii By SD Card Delete by room number Input the room code it will sound BP and the Unlock indicator blinks one time all associated cards will be deleted Delete by User Card Show the User Cards which you need to delete It will sound BP and he...

Страница 14: ...ew Mounting screw The DMR21 automatically assigns the call codes to the connected module s buttons Regardless of the structure of the call button mod ule the button numbers are listed from the top to bottom and from left to right in the case of double row buttons In the case of double row buttons Examples 01 02 03 04 05 06 07 08 RF CARD 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 09 10 11 12 1...

Страница 15: ...8 10 12 14 16 10 12 14 16 18 20 22 24 26 28 30 32 RF CARD RF CARD 01 02 03 04 01 02 03 04 01 02 03 04 05 06 07 08 05 06 07 08 09 10 11 12 13 14 15 16 1 2 3 4 5 6 ON 01 02 03 04 05 06 07 08 NO Functions Call apartment 01 Call apartment 02 Call apartment 03 Call apartment 04 Call apartment 05 Call apartment 06 Call apartment 08 Call apartment 07 DMR21 Technical Manual 15 ...

Страница 16: ...switches for system configurations Connect to CN FUN of video entry module Connect to CN KMB of video entry module Connect to CN WGN of video entry module For electronic lock safety type setting Connect to next keypad or TFT module Connect to next call button module Connect to next call button module Connect to next call button module Call button module connection port Reserved Non polarity bus li...

Страница 17: ... D16 DMR21 T4 D8 DMR21 ID S4 DMR21 ID KP INPUT INPUT OUTPUT OUTPUT CN KMB RF CARD OUTPUT INPUT INPUT CN KMB CN WGN INPUT OUTPUT INPUT CN KMB CN FUN OUTPUT INPUT CN WGN RF CARD A 1 2 3 4 5 6 0 7 8 9 B OUTPUT INPUT CN FUN DMR21 Technical Manual 17 ...

Страница 18: ...A 1 2 3 4 5 6 0 7 8 9 B INPUT INPUT OUTPUT OUTPUT OUTPUT INPUT OUTPUT INPUT OUTPUT INPUT CN KMB CN FUN CN WGN RF CARD OUTPUT INPUT INPUT OUTPUT INPUT OUTPUT INPUT OUTPUT INPUT OUTPUT CN KMB CN WGN MODULE CONNECTION DMR21 Technical Manual 18 ...

Страница 19: ...u want to call 001 Alan_1 08 00 01 Press the first button it would call the monitor 01 in BDU 1 and it is displayed Alan_1 on TFT module This section is reserved For more details please refer to the following section of Namelist Update By SD Card Description Definition Calling By Buttons Calling By Namelist Calling By Keypad Module Press the call button to call corresponding monitors i Press touch...

Страница 20: ... Insert SD card to slot iii A long warning sound of BP will be sent out and the Talk indi cator is turned on iii A long warning sound of BP will be sent out and the Status indicator is turned on iii After 3 seconds all the indicators are turned on iiii After 20 seconds a long sound of BP will be sent out and all indicators are turned off It means Software update is finished iiii After 20 seconds a...

Страница 21: ...switch to ON as the following picture shows ii Insert SD card to slot DIP6 ON 1 2 3 4 5 6 ON INPUT CN KMB CN WGN iii A long warning sound of BP will be sent out and the Talk indi cator is turned on iiii After 20 seconds a long sound of BP will be sent out and the Talk indicator is turned off It means Namelist update is finished CONFIGURATIONS DMR21 Technical Manual 21 ...

Отзывы: