background image

2. Parts and functions

6. Place Name Plate

1. Introductions

Door Station is a unit installed on the entrance of a building, which used to call a 
user in a apartment, and control the electronic lock opening.

This is a guide for quick installation. for more detail instructions, please refer to the 
DT system technical guide.

To call the user, press a button with a associated nameplate of the user; then the 
user will press the Unlock button on the monitor to open the door for the visitor if 
she/he is accepted.

A ID card can be use to open the door.(Only for DMR12/ID series Door Station). 
For detail ID card operation, please refer to DT system technical guide.

A exit button can be connect to the Door Station directly.

The Camera angle can be adjusted to coordinate the install position of the Door 
Station

3. Terminals

1.Remove the bottom cover

2.Remove the anti-theft screw

3.Extract name plate folder, 

   replace name plate

.

-1-

-2-

-3-

1 2 3 4 5 6

ON

T/R -

T/R+

RS-485

SET

L1

+12V
LK - (GND)

CN-LK

JP-LK

BUS

LK+(COM)
N.O.
EB -
EB+

3
2
1

L2

DIP

• 

+12V:

 12VDC power output.

• 

LK-(GND):

 power ground.

• 

LK+(COM):

 electronical load activation ralay contact common.

• 

NO.:

 electronical load activation ralay normally open contact(refer to DT technical 

guide for Lock connection detail informations).

• 

EB+:

 Exit button.

• 

EB-:

 Exit buton.

• 

JP-LK:

 For electronic lock safety type setting(refer to Door Station Lock 

Connections).

• 

T/R-:

 USB-RS485 communication terminal negative.

• 

T/R+: 

USB-RS485 communication terninal positive.

• 

SET:

  DIP switches for system configurations.

• 

Bus(

L1,L2

):

 non-polarised bus line.

4. Connections

This example is one door station wiring, note that the lock used here is a 12Vdc 300mA 
power-to-unlock type. (please refer to DT technical guide for Lock connection detail 
informations)

L1

+12V
LK - (GND)

CN-LK

JP-LK

BUS

LK+(COM)
N.O.
EB -
EB+

3
2
1

L2

Connect to DPS or DBC4S

Exit Button

Electronic Lock

+

-

5. DIP Switches settings

Total 6 bits in the DIP switches can be configured. The switches can be modified 

either before or after installation.

• 

Bit-1 and Bit 2 is for door station ID settings, when mutil door stations are 
installed in the system, these two bit must be set correctly, the first door 
station set to 00, the second one set to 01, the third one set to 10, the fourth 
one set to 11. If only one door station is installed, set to 00.

• 

Bit-3: Single line button door station or double line button door station 
selection. If the door station is a double line button, for examlpe, the DMR12/
D16, set this bit to 0, set to 1 for single line button door stations.

• 

Bit-4: Button code selection; if use the default codes for each button of the 
door station, set to 0, if use the programmed codes, set to 1.(the code for 
each button can be program by the 2Easy+TOOL software, see the program 
section in this manual)

• 

Bit-5: Unlocking time quick selection, by default it is set to 0, for 1 second 
unlocking time; set to 1 for 5 seconds(by default).

• 

Bit-6: Set to 1,it is for door station ID settings,for examlpe,the DMR12/ID/
S4 and DMR12/ID/D8 must be set to 1;set to 0,it is not for door station ID 
settings,for example,the DMR12/S8 and DMR12/D16 must be set to 0. 

ON(1)

OFF(0)

1 2 3 4 5 6

ON

DIP

ON

ON

Speaker

Camera Lens

Microphone

Name plate

Call button

Camera Angle

adjustment

With rainy cover

Отзывы: