BRC944B2
QUG-BRC944B2_10/08
Quick User Guide
BRC944B2 Controller
1.
Operation Light
: Lit when system is operating.
2.
ON / OFF
: Start/Stop operation of the system with the
ON/OFF button.
3.
Changeover
indicates that you cannot changeover
heating/cooling with the remote controller. The absence of
this icon indicates that the controller is designated as the
changeover master with authority to change the system
mode between heating & cooling. See details in the
installation manual.
4.
Operation Mode
: Displays the current operation mode:
AUTO-DRY-COOL-HEAT.
5.
FAN Speed Display
:
Five levels of
Fan
speed,
Automatic
, or
Nighttime
are available.
6.
SWING mode
:
Use to oscillate the vertical/
horizontal louvers, providing a varying air distribution pattern.
7.
MODE selection button
: Depending on prior settings, the
MODE button can select operation mode from
DRY, AUTOMATIC, COOLING, or HEATING.
AUTO
Auto changeover - Cooling and Heating switch
automatically to maintain the desired setpoint temperature.
DRY
Cooling Operation
−
Unit operates to
minimize temperature change but reduces room humidity
levels. Airflow rate cannot be adjusted in this mode.
COOL
Cooling Operation
−
To the desired setpoint
temperature.
HEAT
Heating Operation
−
To the desired
setpoint temperature.
8.
SWING Mode selection button
: Press to change airflow
direction of the louvers. Press again to stop airflow. You can
use this button by selecting/deselecting to position the
louvers as needed. *With Wall-mounted types without
horizontal swing function, pressing the SWING button moves
the louvers vertically.
9.
FAN Airflow selection button
: Press to adjust fan airflow
rate, Automatic, or Nighttime levels.
10.
Temperature selection UP/DOWN buttons:
Used
for
selection range to adjust the current setpoint or, when
in programming mode, to adjust the programmed
setpoint temperature. Hold buttons down for 5 seconds
to switch from
F
ahrenheit to
C
entigrade.
Temperature range is 64-90
°
F / 18-32
°
C.
11.
Timer UP/DOWN
: These buttons set current time/Timer.
12.
Clock setting button
:
Press button and [
0:00
]
lights. Press up/down arrows to select current time.
13.
Timer SET button
: Press when programming is completed.
14.
ONE TIME / DAILY timer setting button
: Automatically
turns off operation when you sleep and turns it back on when
you wake up. Use the DAILY Timer mode on weekdays, and
the ONE TIME timer mode on weekends. The Timer will
show a “
l”
to indicate ON, or a “
O”
to show it is OFF.
* Even if the timer has been off, its programmed settings are
active in memory.
15.
Hour Timer Display
: Displays Daily Timer Programs.
16.
ONE TIME DAILY TIMER display
:
ONETIME
is displayed
when the
ON/OFF Timer
is operational.
DAILYTIMER
is
displayed when the system is being controlled per the Timer
settings. [
1
] denotes only one schedule is programmed, [
2
]
denotes that two separate shedules are programmed.
4. Operation Modes
5. Fan Speed Display
7. MODE selection
8
. S
W
I
N
G Mode selection
3. Changeo
v
er
15. TIME
O
N
E TIME DAILY TIMER 16.
2. O
N
/ OFF
9. FA
N
Airflo
w
selection
10. TEMP selection
TIMER UP/DO
WN
11.
Timer SET 13.
Clock Setting 12.
6. S
w
ing mode indicator
O
N
E TIME DAILY 14.
Ho
u
r Timer Display 15.
1. Operation Light
Display
74