background image

 

 

 

 

 

Digital Multimeter 

ZUTEMER 17 

 

User Manual 

 

 

 

 

www.zutemer.cz

 

 

Summary of Contents for 17

Page 1: ...Digital Multimeter ZUTEMER 17 User Manual www zutemer cz ...

Page 2: ... 4 Select correct function and range to avoid misoperation The instrument of this series has full range protection function but for the sake of safety you shall still pay attention to this point 5 Do not input a current higher than 10A when measuring the current 6 The safety sign indicates the existence of dangerous voltage indicates grounding indicates dual insulation indicates that operator must...

Page 3: ...nce 2 6 DC current DCA Range Accuracy Resolution 400uA 1 5 3 0 luA 4000uA luA 40mA 10uA 400mA 100uA 10A 10mA Maximum voltage drop measured Full range mA 400mV A 100mV Maximum input current 10A not more than 10s Overload protection 0 5A 250V fuse 10A 250V fuse 2 7 True effective value of AC current ACA Range Accuracy Frequency scope Resolution 400uA 1 5 3 40Hz lkHz 0 luA 4000uA luA 40mA 10uA 400mA ...

Page 4: ... protection DC or AC250V peak value Warning It s forbidden to input voltage value in this range for the sake of safety 2 11 Temperature Range Accuracy Resolution 20 1000 400 C 土 1 0 5 400 1 5 15 1 4 1832 752 1 0 5 752 F 1 5 15 1 Sensor K type nickel chromium nickel silicon Warning It s forbidden to input voltage value in this range for the sake of safety IV Application Method 4 1 Description of op...

Page 5: ...oint contacted by the red multimeter probe will be displayed on the screen NOTES 1 Under the mode of manual range if the LCD displays OL it indicates going beyond the range and RANGE key shall be rotated to a higher level 2 The voltage measured shall never exceed DC1000V or the instrument circuit will possibly be damaged 3 Never contact the high voltage circuit measured 4 3 DC millivolt voltage me...

Page 6: ...red multimeter probe into mA or 10A hole maximum 400mA or 10A 2 Rotate the functional switch to current level press SELECT key to select AC measurement mode and then connect the probe of the instrument to the tested circuit The current value tested will be displayed on the screen simultaneously NOTES 1 If having no idea about the scope of current measured users shall rotate the range switch to the...

Page 7: ... probe into VΩHz hole the polarity of red multimeter pole is 2 Rotate the functional switch to or level 3 Measurement in forward direction Connect the red black multimeter probe to the positive negative pole of the tested diode and the display unit will display the approximate value of the voltage drop in forward direction of the diode 4 Measurement in backward direction Connect the red black mult...

Page 8: ...lkalic batteries in order to extend the service life 5 3 Install the battery door and fasten the screws 6 Fuse replacement The steps are the same as above For replacement of fuse please use fuse of the same specification and model NOTES 1 Don t connect the voltage higher than DC1000V or AC750V peak value 2 Don t measure voltage value at AC resistance diode and buzzer levels 3 Don t use this instru...

Reviews: