background image

User Manual

Summary of Contents for NSP-HEPA

Page 1: ...User Manual ...

Page 2: ...anual keep it in a convenient location for further reference Contents Performance Indicators 1 Packing List 2 Filter Features 2 Product Overview 4 Circuit Diagram 4 Install Filter 5 Control Overview 6 Function Descriptions 8 Installation Notice 9 Safety Precautions 10 Mandatory Items 12 Cleaning and Maintenance 13 Replacing the Filters 15 Troubleshooting 16 ...

Page 3: ...a will also change due to various factors such as the degree of indoor pollution Performance Indicators SKU Product Name Rated Voltage Rated Frequency Power Noise Low Ionizer CADR PM2 5 CCM PM2 5 CADR Formaldehyde CCM Formaldehyde Application Area Filter Replace Time Net Weight Product Size Packing Size Purification NSP HEPA Zogics NSpire H13 HEPA Air Filtration System 110V 120V 50Hz 60Hz 80W 29 4...

Page 4: ...harmful gases released by plywood furniture wallpapers carpets curtains and bedspreads Honeycomb Activated Carbon Filter The honeycomb activated carbon carries efficient additives It features good absorption and dust collection characteristics Antibacterial Filter The 5 microns filter with antimicrobial agents can efficiently kill bacteria in the air High Efficiency H13 HEPA Filter The precision o...

Page 5: ... air and eliminates odor caused by smoke and mold Anion Release The ionizer releases a large amount of anions and makes the oxygen negatively charged thus gathering positively charged particles like floating dust bacteria viruses and smoke The particles become denser and sink to the ground The smaller the particle size the higher the capture rate ...

Page 6: ...4 Product Overview Circuit Diagram ...

Page 7: ...ensure the tab side is facing you Install filter 2 Cold catalyst Activated carbon removal compound filters Note Please ensure the tab side is facing you Install filter 1 Pre Filter Note Please ensure the handle side is facing you Install front plate Take out the filters Remove all packaging material Filters are wrapped in plastic this MUST be removed before use ...

Page 8: ... the child lock is pressed The child lock icon will light up and the unit will keep running Press this button for 3 seconds to exit this mode Ionizer will turn on off when you press this button The icon will light up and off accordingly Motor will turn on and stay at low speed mode if you press this button while on standby mode Press this button to set the working time Every press increases the ti...

Page 9: ...h speed The display panel and light will turn off when sleep mode starts Motor will only work at low speed Timer is available in this mode Machine will be in standby mode after the time setting finishes Press any button to exit sleep mode Press this button to adjust the motor speed to Low 500RPM Medium 700RPM High 900 RPM and let the machine exit auto mode The motor speed won t be controlled by th...

Page 10: ...ime and it will stop running automatically after the time is up If you need to cancel press the timer icon on the panel 3 seconds to cancel this function Child Lock mode When in child lock mode the control panel and buttons on the remote control can not work To cancel press the child lock button 3 seconds or press the unlock button on the remote control 3 To Set the Time Press the smart key for 5 ...

Page 11: ...r to make effective air circulation in the room There should be a gap of at least 8 at both sides and back of the product and 12 from the top surface 4 Do not place anything on the product otherwise it may cause the unit to malfunction 5 Do not block the air inlet and outlet For example do not place anything on the outlet or front air inlet 2 This product should be placed on the ground Pollen dust...

Page 12: ...ord is damaged to avoid danger the cord must be replaced by the manufacturer maintenance department or professional staff 3 Do not use beyond the rated power universal socket or connected devices this may cause the cord to overheat and cause a fire accident 4 Do not touch the power plug with wet hands it may cause electric shock 5 Do not place fingers or metal objects into the air outlet gap this ...

Page 13: ... to have access to the remote control 11 Do not place in unstable places Products may drop be overturned resulting in injury causing leakage electric shock or fire 12 Do not use air filter in an aromatherapy scented or disinfecting insecticide environment chemical residues may accumulate in the machine then be released from the outlet causing harm to your health 13 After using a disinfectant or in...

Page 14: ...l off the plug from the power cord may cause power cord damage electric shock short circuit and or fire 6 When any of the following occurs please immediately turn off the machine A switch does not work The power cord or plug abnormally heats up Abnormal sound or vibration Any anomalies or malfunctions 7 Non professional people are not allowed to install or uninstall the machine For IEC This applia...

Page 15: ... not be made by children without supervision 1 Pre Filter Every 15 days Please use a vacuum cleaner to clean the dust on the surface of the screen or wash with water dry thoroughly 2 Cellular Activated Carbon Filter Every 2 months Use a vacuum cleaner to clear the dust on the surface of the screen Place the filter into a ventilated place Don t expose the filter to strong sunshine Do not forcibly h...

Page 16: ...uter cover of the particle sensor fig 1 use the dry cotton swab to clean the lens fig 2 Please disconnect the power before cleaning Cleaning and Maintenance Tips Disconnect the power before cleaning and maintenance Do not open the machine when removing the filter Please unplug if the machine is not in use for a long time According to locations and air quality e g a family with many smokers or a pl...

Page 17: ...A Filter We suggest maintaining No 1 filter every 15 days We suggest maintaining No 2 and No 3 filters every 60 days We suggest replacing No 1 filter in every 2 years We suggest replacing No 2 No 3 filters every 6 months Filter change reminder The machine has a filter change reminding function It s set at 1500 hours Please replace No 2 and No 3 filters when the change icon lights up Also please pr...

Page 18: ...s the child lock button 5 seconds until the light is off 4 The machine is in a flat place Put the machine on a flat surface 1 Is the machine located in a place that does not easily absorb the dirty air Change the location 2 Particle sensor is dirty Clean the sensor The negative ion generator is dusty Clean the negative ion generator 1 Is the filter dirty Clean the filter 2 Has the filter not been ...

Page 19: ......

Page 20: ...888 623 0088 hello zogics com zogics com ...

Reviews: