Flushing/Descaling Procedures

  1. Follow and understand all safety related information provided with the 

tankless water heater as well as the flushing system before starting the 

flushing operation.  Wear appropriate safety apparel including safety glasses 

and rubber gloves.  Inspect all hoses and electrical cords for any kinks, 

cuts, etc. that could result in an electrical shock hazard or fluid leakage.  

Replace any worn or damaged components.  Consult appliance instruction 

manual for complete flushing instructions.

  2.  Disconnect power to the tankless water heater, following the instructions 

provided with the appliance.

  3.  Drain the water heater following the instructions provided with the appliance.

  4.  Close the Cold Water Supply Valve and Water Heater Outlet Valve, isolating 

the heat exchanger.

  5.  Connect a hose (supplied with the system) from the fitting labeled “Pump 

Discharge” on top of the Flushing System to the Service Valve on the Cold 

Water Supply side of the water heater.

  6.  Connect a hose (supplied with the system) from the fitting labeled “Return” 

on top of the Flushing System to the Service Valve on the Hot Water outlet 

side of the water heater.

  7.  Remove the black threaded cap on top of the system and add no more than 2 

gallons of virgin food grade white vinegar to the tank.  Replace the threaded 

cap.  Make sure the included o-ring is properly seated in the cap to provide 

a leak proof seal.

  8.  Open the Hot and Cold Service Valves to the water heater heat exchanger.

  9.  Plug Power Cord from the Flushing System Pump to a properly grounded 

electrical receptacle.  Never allow the pump to run without adequate liquid 

in the tank or possible damage to the pump may occur.

 10.  Allow the pump to circulate the vinegar solution for at least 45 minutes 

or per the appliance manufacturer’s recommendation (consult appliance 

instruction manual).  Monitor the system for leaks or any peculiar behavior.  

Unplug the power cord if the pump stops, an external leak develops, or the 

flow is greatly reduced.

 11.  After the required time expires, unplug the power cord from the receptacle.

 12.  Close the Service Valve on the Cold Water Supply line and disconnect the 

hose end from the Service Valve.

 13.  Disconnect the hose end from the Flushing System “Return” Line Connection 

and route it to a suitable drain or to a bucket.  Connect an extra length of 

hose if necessary.

 14.  Open the Cold Water Supply Valve to flush the water heater with fresh 

water, rinsing out the cleaning solution.  Let the system flush for 5 minutes 

or as required per the appliance instructions.  Monitor the discharge from 

the hose.  If using a bucket, empty as needed.

 15.  After  the  required  time  expires,  close  the  Hot  Water  Service  Valve  and 

disconnect the hose.

 16.  Open the Hot Water Supply Valve.

 17.  Restore power to the heater system and return it to service.

After completing the flushing operation:

  1.  Discard the contents of the Flushing System by removing the threaded cap 

from one of the tank access connections on the top or side of the tank.  Pour 

the contents into a suitable drain.

  2.  Remove the Return fitting from the top of the tank to access the strainer 

assembly.  The strainer element is connected to the fitting with a hose clamp.  

Loosen the clamp to remove the strainer.  Discard the contents of the strainer 

and rinse away any remaining particles.  Inspect the strainer for any tears or 

damage.  Replace the strainer as needed.  Order P/N 150786.  Re-assemble 

the strainer to the fitting assembly and tighten clamp.

  3.  Replace the fitting assembly into the cover of the tank.

  4.  Add approximately one gallon of fresh water to the tank.  Connect a hose 

to the Pump Discharge connection and route to a suitable drain.  Plug in 

the pump to flush the vinegar solution out of the pump.  Pour any remaining 

liquid from the tank and replace threaded caps.

  5.  Store the pump system in an appropriate location to prevent damage by 

impact and temperature extremes.

SK2793

Water heater connections may vary.  Consult appliance 

owner's manual for actual connection locations.

SRS

SCALE
REMOVAL
SYSTEM

®

 INSTALLATION INSTRUCTIONS 

PREINSTALLATION CHECKLIST

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

P/N 152644

Reviews: