MODEL 510

“THE BASEMENT SENTRY

®

 

II

12 VOLT DC BACKUP PUMP

PREINSTALLATION CHECKLIST

Section: 6.10.075

FM1139

0113

Supersedes

0608

notice to inStALLeR: instructions must remain with installation.

1.  inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer 

before using.

2.  Read all the installation instructions regarding installing and start up. Retain for future reference.

SEE BELOW FOR 

LIST OF WARNINGS

SEE BELOW FOR 

LIST OF CAUTIONS

1.  testing for Ground. As a safety measure each electrical outlet should 

be checked for ground using an Underwriters Laboratory listed 

circuit analyzer, which will indicate if the power, neutral and ground 

wires are correctly connected to your outlet. If they are not, call a 

qualified licensed electrician.

2.  For your protection always disconnect the power supply from its 

power source before handling the components of your DC backup 

pump or the primary pump.

3.  Installation and checking of electrical circuits and hardware should be 

performed by a qualified, licensed electrician. 

4.  All electrical and safety codes must be followed in addition to the 

National Electrical Code and all applicable local codes.

5. 

It is the owner’s responsibility to check the battery and 

battery connection at least once a month. Batteries contain 

acid and caution must be taken when handling.

6.  Risk of electric shock - These pumps have not been investigated for 

use in swimming pool areas.

7.  According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and birth 

defects or other reproductive harm.

1.  Make sure there is a properly grounded 115V receptacle available. 

Do not use primary pump circuit. The location must be within 6' of 

the control box and battery. The power supply for your DC control 

system plugs directly into the 115V outlet. Do not uSe An 

extenSion coRD.

2.  Make sure the 115V electrical supply circuit is equipped with 

fuses or circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do not 

use in septic tanks to pump effluent or sewage pits to pump sewage.

4.  Repair and service of your DC backup system should be performed 

by an authorized service station.

5.  The installation of DC automatic backup pumps requires the use of 

a variable level float switch for operation. It is the responsibility of 

the installing party, to ensure that the tethered float switch will not 

hang up on the pump apparatus or pit peculiarities and is secured 

so the pump will turn “on” and “off”. It is recommended that the pit 

be 18" in diameter or larger to accommodate both a primary and a 

DC backup pump. 

ReFeR to WARRAnty on pAGe 2.

 Turbulence caused by high velocity incoming water 

can cause the DC pump to airlock. If this condition exists, the incoming 

water must be baffled to avoid excessive turbulence.

ANY CHANGES MADE TO THIS DOCUMENT ALSO MAY AFFECT FM1311, FM1311S, FM1311F AND HF1312.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

© Copyright 2013 Zoeller Co. All rights reserved.

Summary of Contents for BASEMENT SENTRY II

Page 1: ...chemicals known to the state of California to cause cancer and birth defects or other reproductive harm 1 Makesurethereisaproperlygrounded115Vreceptacleavailable Do not use primary pump circuit The location must be within 6 of the control box and battery The power supply for your DC control system plugs directly into the 115V outlet Do not use an extension cord 2 Make sure the 115V electrical supp...

Page 2: ...an not be restarted until power is restored and the battery recharged b If power has been restored and water in sump remains high check primary pump Service if required c Acompletelydrainedbatterymayrequire18hoursforafullcharge 7 Alarm sounds during battery recharge cycle a Pushalarmreset max 3times Ifconditionpersists replacebattery Troubleshooting Information Manufacturer warrants to the purchas...

Page 3: ...Deep cycle 12 volt 130 amp hour marine batteries are recommended and will provide approximately 7 hours of continuous pumping time in a sump pump installation with 8 of head pressure In most installations the pump runs intermittently and the battery life is extended accordingly Batteries with top terminals are recommended for ease of installation Pumping time can also be extended by using addition...

Page 4: ...at switch assembly on the lower leg of the discharge outlet tee using the clamp provided see fig 1 and 2 Set tether length to 4 Position pumps in the sump and move float up and down making sure of free movement without interference from any obstructions inside the sump or lid Very shallow sumps may require some adjustment to avoid overfilling or backing up of water into the sump inlet The float sw...

Page 5: ... The 8 3 8 Dimension can be altered to accommodate small basins with min depth of 24 ON LEVEL PRIMARY PUMP END OF PIPE END OF PIPE 7 3 16 PIPE REMOVED OUTLET PUMP PRIMARY BATTERY BOX 8 3 8 5 3 8 1 8 WEEP HOLE 1 8 WEEP HOLE BATTERY BOX PRIMARY PUMP ON LEVEL 7 1 2 5 3 8 8 3 8 END OF PIPE END OF PIPE 7 3 16 PIPE REMOVED PRIMARY PUMP OUTLET ...

Page 6: ...served PUMP LOOP ASSEMBLY FIGURE 3 FIGURE 4 FLOAT SWITCH SK1220 SK957 4 C B A C B A 9 8 5 6 6 7 5 10 1 PUMP LOOP ASSEMBLY BRACKET AND BOTTOM VIEW OF PUMP SUPPLIED BY CUSTOMER DISCHARGE PIPE 1 8 WEEP HOLE 1 8 WEEP HOLE CLAMP PIPE CLAMP 4 TETHER ...

Page 7: ...ICATOR YELLOW PUMP MODE INDICATOR LEAD TO POSITIVE BATTERY TERMINAL LEAD TO NEGATIVE BATTERY TERMINAL FEMALE PLUG FOR PUMP CONNECTION FEMALE PLUG FOR FLOAT SWITCH CONNECTION NONGROUNDED POWER CORD ALARM SILENCE INDICATOR PUMP RUN INDICATOR RED LED YELLOW GREEN LED RED LED YELLOW LED CHARGER RESET LESS THAN 3 SECONDS PUMP TEST GREATER THAN 3 SECONDS TEST SWITCH RED LOW BATTERY INDICATOR ALARM SILEN...

Page 8: ... and the condition of the battery Follow these recommendations Use a B C I size 27 deep cycle battery 175 minute reserve capacity or larger Do NOT use a maintenance free battery unless it is a Gel filled or AGM battery Replace your battery every 3 years Do not let corrosion build up on the battery terminals Do not place your battery on a concrete floor where it will discharge faster To check speci...

Reviews: