background image

FM3120

0119

Supersedes

1218

12 VOLT DC BATTERY BACKUP PUMP

INSTALLATION INSTRUCTIONS

PREINSTALLATION CHECKLIST 

1.  Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.

2.  Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future 

reference.

SEE BELOW FOR 

LIST OF WARNINGS

1.  Testing for ground. As a safety measure each electrical outlet should 

be checked for ground using an Underwriters Laboratory listed circuit 

analyzer, which will indicate if the power, neutral and ground wires are 

correctly connected to your outlet. If they are not, call a qualified, licensed 

electrician.

2.  For your protection, always disconnect the power supply from its power 

source before handling the components of your DC backup pump or the 

primary pump.

3.  Installation and servicing of electrical circuits and hardware should be 

performed by a qualified, licensed electrician. 

4.  All electrical and safety codes must be followed including the National 

Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the battery and battery 

connection at least once a month. Batteries contain acid, and 

caution must be taken when handling.

6.  Risk of electric shock. These pumps have not been investigated 

for use 

in swimming pools and marine areas.

7.  Prop65 Warning for california residents: Cancer and Reproductive Harm- 

www.P65Warning.ca.gov.

1.  Make sure there is a properly grounded 115 V receptacle available. Do 

not use primary pump circuit.

 The location must be within 6' (1.8 m) of 

the control box and battery. The power supply for your DC control system 

plugs directly into the 115 V outlet. 

DO NOT USE AN EXTENSION CORD.

2.  Make sure the 115 V electrical supply circuit is equipped with fuses or 

circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do not use 

in septic tanks to pump effluent or in sewage pits to pump sewage.

4.  Repair and service of your DC backup system should be performed by 

an authorized service station.

5.  The installation of DC automatic backup pumps requires the use of a 

variable level float switch for operation. It is the responsibility of the 

installing party to ensure that the float switch will not hang up on the 

pump apparatus or pit peculiarities and is secured so the pump will turn 

“on” and “off”. It is recommended that the pit be 18" (45.7 cm) in diameter 

or larger to accommodate both a primary and a DC backup pump.

6.  For indoor use only.

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

CAUTION

    Turbulence  caused  by  high-velocity  incoming 

water can cause sump pumps to airlock. If this condition exists, 

the incoming water must be baffled to avoid excessive turbulence.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624

Visit our web site:

zoellerpumps.com

© Copyright 2019 Zoeller

®

 Co. All rights reserved.

Real Time Peace of Mind.™

Patent No. 

D740329

Summary of Contents for 508-0014

Page 1: ...arning ca gov 1 Make sure there is a properly grounded 115 V receptacle available Do not use primary pump circuit The location must be within 6 1 8 m of the control box and battery The power supply for your DC control system plugsdirectlyintothe115Voutlet DO NOTUSEANEXTENSIONCORD 2 Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emer...

Page 2: ...eset button for 3 seconds to reset the controller and clear any alarms or indicators 2 Plug the controller and the primary pump into the wall outlet a The primary pump will come on lower the water to the normal operating level and shut off b The battery light will be yellow when charging The charger is replacing the energy consumed during the test The green light will come on after the charger has...

Page 3: ...nstallation Wet cell batteries contain acid and proper precaution must be taken when handling Battery box will accommodate a maximum battery size of 13 1 2 34 3 cm Length x 7 17 8 cm Width x 9 1 2 49 5 cm Height AGM batteries also recommended Do not use gel batteries or automotive batteries Pump Construction Non corrodible plastic premium seals Performance 35 GPM at 10 113 LPM at 3 m at 12 6 volts...

Page 4: ...p or lid The float switch can be moved on the discharge pipe or the rubber stops can be adjusted as necessary Cut extra float rod length below lower float stop to prevent debris from interfering with float operation Install the high water switch with the on level set at least 1 2 5 cm above the on level of the operational float using the supplied clamp Move the switch up and down ensuring free mov...

Page 5: ...FF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHERTHAN DC BACKUP PUMP DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX AQUANOT FIT CONTROLLER OUTLET CHARGER HI WATER REED SENSOR OPERATIONAL FLOAT SWITCH AQUANOT FIT CONTROLLER 30 AMP FUSE HI WATER REED SWITCH BATTERY BOX DC PUMP 12 VOLT BATTERY SUPPLIED BY USER WHITE LEADTO POSITIVE BLACK LEADTO NEGATIVE CLAMP EXPLODED VIEW DC PUMP FIGURE 2 SK318...

Page 6: ...start the 24 hour timer for self testing AQUANOT FIT Solid Flashing Off System Ready No Faults Green AC off with no faults Green Battery Charged Green Low Battery Red No AC Power Charging Yellow Bad Battery Red DC pump Pump Ran Yellow Pump Running Yellow Pump Fault Red Float Status High Water Red Float Fault Red Z Control Connected Searching Broadcasting SSID or Dormant The LEDs will display infor...

Page 7: ...ion process Create a free account at zcontrolcloud com Locate the Fit s Device ID on the top sticker Connection Steps 1 Apply AC Power to the Fit The Z Control LED will blink and then turn off indicating the Fit is in AP Mode and is transmitting an SSID see Figure B If the LED is blinking and not in AP mode press the Z Control button for 12 seconds and let go The LED will now be off indicating the...

Page 8: ... choose the WiFi you want the Fit to use for internet connectivity Enter the password for the router you chose in the field indicated If the password is correct the Fit will connect to the router and start sending status updates to zcontrolcloud com You will see the Z Control LED go from blinking to solid This could take up to a minute or so If the LED does not turn solid then the password entered...

Page 9: ...oud com see Figure D Click the Edit button next to a location and choose Add New Device Follow the directions to add your Fit by either auto detect or entering the Device I D When successful a Fit product tile will appear in your account The Fit is capable of OTA or over the air firmware updates It s possible that the Fit could perform an update immediately if one is available at the Z Control Clo...

Page 10: ... CO is being produced a charging battery may be producing gaseous by products which are causing the CO detector to activate Contact the manufacturer and ask for recommendations to prevent the alarm activation There are millions of batteries manufactured each year so it is impossible to guarantee consistent quality A defective battery will never become fully charged and may damage the charging circ...

Page 11: ..._ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ _______________________________________________________________________________ ______________________________________________________________________________...

Page 12: ... 40256 0347 SHIPTO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our web site zoellerpumps com These are the original installation instructions Copyright 2019 Zoeller Co All rights reserved ...

Reviews: