background image

Product Name and Model Number

 

                

User Manual 

 

P a g e

 |  1 

Copyright©2020 ZKTECO CO., LTD.    All rights reserved. 

Thank you for choosing our product. Please read the instructions carefully 
before operation. Follow these instructions to ensure that the product is 
functioning properly. The images shown in this manual are for illustrative 
purposes only. 

For further details, please visit our Company’s website 

www.zkteco.com

 
 
 
 
 
 

          

 

 
 
 
 
 
 

User Manual 

CMP-200 

Date: June 2020   
Doc Version: 1.1 
English 

Summary of Contents for CMP-200 Series

Page 1: ...duct Please read the instructions carefully before operation Follow these instructions to ensure that the product is functioning properly The images shown in this manual are for illustrative purposes only For further details please visit our Company s website www zkteco com User Manual CMP 200 Date June 2020 Doc Version 1 1 English ...

Page 2: ...heir respective owners Disclaimer This manual contains information on the operation and maintenance of the ZKTeco product The copyright in all the documents drawings etc in relation to the ZKTeco supplied product vests in and is the property of ZKTeco The contents hereof should not be used or shared by the receiver with any third party without express written permission of ZKTeco The contents of t...

Page 3: ...nual and the contract specifications drawings instruction sheets or any other contract related documents the contract conditions documents shall prevail The contract specific conditions documents shall apply in priority ZKTeco offers no warranty guarantee or representation regarding the completeness of any information contained in this manual or any of the amendments made thereto ZKTeco does not e...

Page 4: ...es the information herein which will be incorporated into new additions amendments to the manual ZKTeco reserves the right to add delete amend or modify the information contained in the manual from time to time in the form of circulars letters notes etc for better operation and safety of the machine unit product The said additions or amendments are meant for improvement better operations of the ma...

Page 5: ...ut our global branches visit www zkteco com About the Company ZKTeco is one of the world s largest manufacturer of RFID and Biometric Fingerprint Facial Finger vein readers Product offerings include Access Control readers and panels Near Far range Facial Recognition Cameras Elevator floor access controllers Turnstiles License Plate Recognition LPR gate controllers and Consumer products including b...

Page 6: ...tion ecosystem and smart security ecosystem which are based on biometric verification techniques With years of experience in the industrialization of biometric verifications ZKTeco was officially established in 2007 and now has been one of the globally leading enterprises in the biometric verification industry owning various patents and being selected as the National High tech Enterprise for 6 con...

Page 7: ...ion Button or key names for devices For example press OK Window names menu items data table and field names are inside square brackets For example pop up the New User window Multi level menus are separated by forwarding slashes For example File Create Folder Symbols Convention Description This implies about the notice or pays attention to in the manual The general information which helps in perfor...

Page 8: ...ON 8 2 WHAT IS IN THE BOX 8 APPEARANCE AND DIMENSIONS 9 3 PRODUCT INSTALLATION 10 INSTALLATION PRECAUTIONS 10 CABLE EMBEDDING 10 BOOM INSTALLATION 11 4 TECHNICAL PARAMETERS 12 5 FUNCTIONS 13 6 MOVEMENT TRANSMISSION STRUCTURE 14 7 CONTROL BOARD WIRING INSTALLATION 15 8 COMMISSIONING INSTRUCTIONS 19 9 TROUBLESHOOTING 22 ...

Page 9: ... and structure design are adapted to the market and the industry requirements and the traffic light indication has the humanized experience As an economical automatic barrier gate device the user can adjust the telescopic straight boom according to the actual requirement to meet various application scenarios 2 What is in the box The box comes with The barrier gate 1 The boom 1 The remote control 2...

Page 10: ...CMP 200 User Manual P a g e 9 Copyright 2020 ZKTECO CO LTD All rights reserved Appearance and Dimensions Left and Right Cabinet View L The cabinet on the left R The cabinet on the right ...

Page 11: ... the spring is designed for adjusting the new balance Do not change the wire connection inside when the power is on The GND should be connected to the cabinet for secure protection Cable Embedding Prepare φ25 protective sleeve and cable in advance Route the cables to be connected through the protective sleeves Use a tool to open the cable board in the ground Control room Screw pad Ground Cabinet E...

Page 12: ...on Boom Installation Procedure Pull the barrier arm out from the main boom and then fasten it with 2 screws as shown in Figure 1 Figure 1 Connect the main boom with vice together by 2 screws Install the boom to the chassis the frame as shown in Figure 2 Figure 2 Installing the Boom to the Chassis ...

Page 13: ...sis material Cold gadolinium steel plate Boom material Aluminum Working temperature 25 75 Working humidity 90 RH no condensation Protection grade IP54 Shell size W D H 1010 350 280 mm Package size W D H 1100 375 430 mm Chassis net weight 45KG Chassis gross weight 47KG Boom type The mainboard is the same Telescopic straight boom boom length 4 5m red and white color the rise fall speed is 3s Telesco...

Page 14: ...ection When the boom operation is abnormal and exceeds the rise and fall time the boom will stop the operation automatically The barrier gate can be controlled by wireless remote control and wired control buttons to meet the needs of different field applications It supports traffic lights with AC voltage and DC voltage of 5V or 12V Mainboard built in fuse secure from overvoltage Supports the conne...

Page 15: ...CMP 200 User Manual P a g e 14 Copyright 2020 ZKTECO CO LTD All rights reserved 6 Movement Transmission Structure ...

Page 16: ... the barrier gate controller and connect the lines one by one firmly Note Power must be disconnected before installation or maintenance After checking and confirming reliable wiring install the wiring cover back Install the Desktop Remote Control Place the Desktop Remote Control on the table in the guard room or attach it to the wall and plug in the power The wiring diagram of the controller is as...

Page 17: ...CMP 200 User Manual P a g e 16 Copyright 2020 ZKTECO CO LTD All rights reserved ...

Page 18: ...17 Copyright 2020 ZKTECO CO LTD All rights reserved Connect to the LPR camera Connection with the UHF controller Note The Reader1 and 2 of the inbio260 controller are corresponding to LOCK1 Reader3 and 4 are corresponding to LOCK2 ...

Page 19: ...CMP 200 User Manual P a g e 18 Copyright 2020 ZKTECO CO LTD All rights reserved Connection with the loop detector Connection with the infrared detector ...

Page 20: ...nd public interface so that the falling boom will start rising immediately and will stop automatically after the rising limit This is mimic the effect of infrared detectors 5 In the process of boom falling short connect the loop detector and public interface the falling boom is transferred to rising immediately which will fall automatically after the rising limit and stop automatically after the f...

Page 21: ...CMP 200 User Manual P a g e 20 Copyright 2020 ZKTECO CO LTD All rights reserved 6 Barrier gate Hall limit switch adjustment 7 Left and right movement interchange method ...

Page 22: ...on on the remote control the REMOTE indicator turns OFF In this process the code of studying will be completed Delete code To process the Code deletion in the STOP state press the Study button on the main controller until the REMOTE indicator is ON continue to press the Study button and hold on until the REMOTE indicator is OFF Note All the codes will be deleted in this process Note One barrier ca...

Page 23: ...ame frequency interference exists 1 Recode 2 Replace the receiving module 3 Change to other frequencies 3 The POWER indicator is on the boom UP and DOWN indicator is normal the motor is not running 1 The motor wire is open or incorrectly connected 2 The motor is stuck 1 Connect the motor wire 2 Manual release motor 4 Unableto rise or fall boom to limit 1 The limit line is misconnected 2 Limit swit...

Page 24: ...ZKTeco Industrial Park No 26 188 Industrial Road Tangxia Town Dongguan China Phone 86 769 82109991 Fax 86 755 89602394 www zkteco com Copyright 2020 ZKTECO CO LTD All Rights Reserved ...

Reviews: