background image

The Zircon

®

 WL 25 Pro Electronic Water Level is an ideal tool  

for determining level reference points up to 25 ft. (7.5 m) away.  

The WL 25 Pro simplifies working alone or around corners with 

accurate and reliable measurements and is ideal for a number  

of applications, including erecting fences, building decks,  

positioning drainage, plumbing, setting forms, completing masonry 

work, or remodeling interiors. The WL 25 Pro features a 25 ft.  

(7.5 m) hose, mounting bracket and screw, hose connector,  

and filler nozzle.

INSTALLING BATTERY  

Press battery door release and  

remove door. Snap 9V battery onto 

connector and place inside battery 

compartment. Replace door and  

snap shut.

ASSEMBLING THE WL 25 PRO

Using the hose connector provided, attach one end of 

the long hose to the lower end of the short hose that 

passes through the body of the unit. There will also 

be a short length extending from the top. Move the 

hose clamps, if necessary, so that one is on the short 

hose extending from the top and the other clamp is at 

the free end of the long hose.

FILLING WITH WATER 

Open the top hose clamp and position the WL 25 Pro  

to allow water to exit the top hose. Attach the  

filler nozzle to an outdoor faucet and turn  

on the water supply. Water will not flow  

until the filler nozzle switch is turned to the 

open position. Open the working end hose 

clamp and press the 25 ft. (7.5 m) long hose to the filler nozzle exit. 

Turn the filler nozzle switch to allow water to fill the long hose  

until water is flowing out of the top hose. Allow the water to flow 

until there is no air exiting the top hose for at least 10 seconds. 

Close the filler nozzle switch and close the working end hose clamp. 

You can also siphon water from a bucket to fill the hose. Ensure the 

hose clamps are locked at each end to keep the water from running 

out as you set up your working area.  

NOTE: To avoid inaccurate readings, always remove large 

air bubbles in the water filled hose before using. To help 

remove air bubbles, unlock both clamps and gently shake 

the hose to force air bubbles to the top

MOUNTING THE WL 25 PRO

Mount the WL 25 Pro so  

that the level reference  

points on the sides are at  

the desired finished level point. 

A mounting bracket and screw 

are included for attaching 

unit to a form. The unit fits 

on the bracket, making height 

adjustments easier.

WL 25 PRO KIT ATTACHMENTS

You can also mount the WL 25 Pro above or below that  

reference point, measuring up or down from your marks to  

the desired position. Fasten the unit at both top and bottom to 

ensure stability. If the unit swings from side to side, your level  

points will change and give you inaccurate readings. 

USING THE WL 25 PRO 

Attach the electronic unit to the work area, then slide the ON/OFF 

button to ON. Lower the working end of the hose to keep water 

below the level line indicator. Open the clamp on the short top 

hose. Move the long length of the hose to the desired level position, 

making sure that the hose is not knotted or kinked and will not  

be kicked, stepped on, or disturbed. Keep the long end of the hose 

lower than the electronic unit until you are ready.
Elevate the end just enough that the water doesn’t run out.  

Open the clamp on the working end of the unit. SLOWLY raise the 

end of the long hose until the continuous tone just starts. Mark a 

line on the work surface matching the level of the water.

Note: If you raise the tube too fast 

and the level point is passed and the 

intermittent tone sounds, lower the 

working tube until the tone stops  

and then SLOWLY raise it again.  

The longer the working tube,  

the more time it takes for the  

water levels to stabilize.

Sensing Tube 

Level Line 

Indicator

Hose Clamp

Power LED 

ON/OFF 

Switch

Audio Output 

Bottom Hose 

Top Hose 

Hose Connector

Hose 

Tube-Cleaning Brush

CLEANING AND STORING 

THE WL 25 PRO

In some areas, high mineral content in water may cause a coating 

to form on the inside of the sensing tube. The WL 25 Pro’s sensing 

tube can be cleaned easily to ensure accuracy. To reduce mineral 

buildup do not leave water in tube overnight.
 Disconnect the longer length of working hose, connector, and 

clamps from the unit. Wet the tube-cleaning brush (included in 

the package) with water. Insert fully into the short 

sensing tube. Rotate the bristles gently to clean the 

contacts, remove brush, and then rinse. Reattach 

the working hose and the level is ready for use.
When quitting work for a short time, you can 

leave the water inside the hose. Lock the 

clamps at each end of the hose, and carefully 

coil the hose.
To prevent corrosion when not in use, unclamp 

the hose at both ends and drain the water from 

the long end of the hose. Store unit with clamps 

open in a dry place and out of sunlight.

ADDITIONAL HOSING IS AVAILABLE  

Stores that sell this product usually sell or can order additional 

hosing in 25 ft. (7.5 m) lengths. You can also call Zircon Customer 

Service at 1-800-245-9265 to order additional hoses if your local 

store does not carry them. The hose interior diameter is 

5

16

 in. 

(8 mm) and comes with an additional connector to allow you to 

extend your working length.

Tube-

Cleaning 

Brush

HELPFUL HINTS

Add a few drops of food coloring to the water before filling.

Replace the water in hose with a mixture of vodka and water.

Always close both clamps after filling tubing.

Be sure to look at the tube from the same angle and mark the 

water level at the same spot in the tube.

Use tube-cleaning brush included with tool to clean pins 

that detect water level.

• Securely fasten electronic unit at both top and bottom.
• Open both clamps and shake tube gently to force bubbles to top.
• Straighten out the tubing.

Water and tubing are clear.

• Unit swings from side to side.
• Large air bubbles in tubing.
• Kinks or knots in tubing.

Clamps open.

Water level being misread.

Pins are dirty.

• Temperature  dropped.
• It’s too cold to work.

Trouble seeing water level.

Water freezes.

Either steady beep or 

intermittent beep does  

not operate.

Unit does not beep at the  

same spot.

Water runs out of tube as 

you set up work area.

Level points change.
Inaccurate readings.

WL 25 Pro Kit

Electronic Water Level

Visit www.zircon.com for the most current instructions.

LIMITED LIFETIME WARRANTY
Zircon Corporation (“Zircon”) warrants to the original purchaser (or original user by gift) 

that this product will be free from defects in materials and workmanship for its useful life 

(not to exceed twenty years from date of purchase). This warranty is limited to the electronic 

circuitry of the product, and specifically excludes consumable parts, including batteries, 

and software, even if packaged with the product. Defects caused by abuse, modification, 

handling contrary to these instructions, other unreasonable use, or neglect are not covered 

under this warranty. No liability is accepted for normal wear and tear and minor defects 

which do not detract from the function of the product.
THIS LIMITED LIFETIME WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES, EXPRESS  

OR IMPLIED, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR 

A PARTICULAR PURPOSE. IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL, INDIRECT, 

INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION, USE, OR 

MALFUNCTION OF THIS PRODUCT. NO OTHER REPRESENTATIONS OR CLAIMS OF A SIMILAR 

NATURE WILL BIND OR OBLIGATE ZIRCON.
Some states do not allow limitations on certain implied warranties and/or the limitation on 

incidental or consequential damages, so the above limitations and exclusions may not apply 

to you. This warranty gives you specific legal rights, and you may also have other rights 

which vary from state to state. This Limited Lifetime Warranty applies only to products 

purchased within the United States of America (USA) and Canada. For warranty applicable to 

products purchased in all other geographical areas, see www.zircon.com/warranty.
Any in-warranty defective product returned to Zircon, freight prepaid, along with dated 

purchase receipt and $10.00 to cover shipping and handling, will be repaired or replaced, 

at Zircon’s option. If the returned product is no longer available, Zircon may replace the 

product with a similar product of similar function. This is your sole and exclusive remedy 

for breach of this Limited Lifetime Warranty. To return product, call the Zircon Customer 

Service number below to request an RMA number and return product with shipment 

tracking to:
Zircon Corporation 

Attn: Returns Department 

1580 Dell Avenue 

Campbell, CA 95008-6992 USA
Include your name, return address, RMA number, and package tracking number.  

Allow 4 to 6 weeks for delivery.
If you do not agree to the terms of this Limited Lifetime Warranty, you may not use this 

product and must promptly return it to the retailer, along with a dated purchase receipt 

within 30 days of purchase for a refund of the purchase price.
Customer Service: 1-800-245-9265 or 1-408-963-4550 

Monday–Friday, 8:00 a.m.–5:00 p.m. PST 

www.zircon.com • [email protected]
©2021 Zircon Corporation • P/N 72294 • Rev A 11/21 
Zircon is a registered trademark of Zircon Corporation.

Intermittent tone sounds;  

level point too high.

Continuous tone sounds;  

level point reached.

No tone sounds;  

level point too low.

Probable Causes

Solutions

Situation

Filler Nozzle

Mounting Bracket

Mounting Screw

Hose Connector

EN

Summary of Contents for WL 25 Pro Kit

Page 1: ...ences building decks positioning drainage plumbing setting forms completing masonry work or remodeling interiors The WL 25 Pro features a 25 ft 7 5 m hose mounting bracket and screw hose connector and filler nozzle WL 25 PRO KIT ATTACHMENTS Sensing Tube Level Line Indicator Hose Clamp Power LED ON OFF Switch Audio Output Bottom Hose Top Hose Hose Connector Hose Tube Cleaning Brush WL 25 Pro Kit El...

Page 2: ...he working end hose clamp and press the 25 ft 7 5 m long hose to the filler nozzle exit Turn the filler nozzle switch to allow water to fill the long hose until water is flowing out of the top hose Allow the water to flow until there is no air exiting the top hose for at least 10 seconds Close the filler nozzle switch and close the working end hose clamp You can also siphon water from a bucket to ...

Page 3: ...he desired level position making sure that the hose is not knotted or kinked and will not be kicked stepped on or disturbed Keep the long end of the hose lower than the electronic unit until you are ready Elevate the end just enough that the water doesn t run out Open the clamp on the working end of the unit SLOWLY raise the end of the long hose until the continuous tone just starts Mark a line on...

Page 4: ...ting work for a short time you can leave the water inside the hose Lock the clamps at each end of the hose and carefully coil the hose To prevent corrosion when not in use unclamp the hose at both ends and drain the water from the long end of the hose Store unit with clamps open in a dry place and out of sunlight ADDITIONAL HOSING IS AVAILABLE Stores that sell this product usually sell or can orde...

Page 5: ...tronic unit at both top and bottom Open both clamps and shake tube gently to force bubbles to top Straighten out the tubing Water and tubing are clear Unit swings from side to side Large air bubbles in tubing Kinks or knots in tubing Clamps open Water level being misread Pins are dirty Temperature dropped It s too cold to work Trouble seeing water level Water freezes Either steady beep or intermit...

Page 6: ... IMPLIED INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE IN NO EVENT WILL ZIRCON BE LIABLE FOR ANY SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM POSSESSION USE OR MALFUNCTION OF THIS PRODUCT NO OTHER REPRESENTATIONS OR CLAIMS OF A SIMILAR NATURE WILL BIND OR OBLIGATE ZIRCON Some states do not allow limitations on certain implied warran...

Page 7: ...1580 Dell Avenue Campbell CA 95008 6992 USA Include your name return address RMA number and package tracking number Allow 4 to 6 weeks for delivery If you do not agree to the terms of this Limited Lifetime Warranty you may not use this product and must promptly return it to the retailer along with a dated purchase receipt within 30 days of purchase for a refund of the purchase price Customer Servi...

Reviews: