USER

GUIDE

V1.0

IR

EXTENDER

Infrared

Summary of Contents for ZXT-120

Page 1: ...This guide describes how to install program and operate Zipato IR Extender How can I manage all security issues with one easy intuitive and efficient solution USER GUIDE V1 0 IR EXTENDER Infrared ...

Page 2: ... technical inaccuracies typographical or other errors Zipato assumes no liability for any error in this publication and for damages whether direct indirect incidental and consequential or otherwise that may result from such error including but not limited to loss of data or profits Zipato provides this publication as is without warranty of any kind either express or implied including but not limit...

Page 3: ... electrical shock from such facilities Avoid contact with all such facilities Ethernet wiring must be at least 2 m from bare power wiring or lightning rods and associated wires and at least 15 cm from other wire antenna wires doorbell wires wires from transformers to neon signs steam or hot water pipes and heating ducts ELECTROMAGNETIC COMPATIBILITY In proper state and when operated properly the p...

Page 4: ...XTENDER OPERATIONS 08 INSTALLATION 20 TROUBLESHOOTING 25 SPECIFICATIONS 27 IR EXTENDER CODE LIST 34 LIMITED PRODUCT WARRANTY 40 DECLARATION OF CONFORMITY 46 CONTENTS 04 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com ...

Page 5: ...t in temperature sensor which allows gateway or controller to get the current room temperature ZXT 120 can be configured as either Frequently Listening Routing Slaves FLiRS or Always Listening node after exclusion process before inclusion process FLiRS node type is for battery operated applications and it will enter sleep mode frequently in order to conserve battery consumption that can provide th...

Page 6: ...k using the primary controller Then the user can use either the primary controller or secondary controller to configure and setup the ZXT 120 using Z Wave s configuration command class Once the configuration and setup is complete the controller can use Z Wave Thermostat commands class to control their IR controlled air conditioner through the ZXT 120 CONTROLLER AND GATEWAY REQUIREMENTS The ZXT 120...

Page 7: ... controllers operating on the same system A Z Wave network has its own unique ID code so that controllers not in the network cannotcontrolthesystem PRIMARY CONTROLLER The first controller is used to set up your devices and network Only the Primary Controller can be used to include or delete devices from a network It is recommendedthat you mark the primary controllerforeachnetworkforeaseinmodifying...

Page 8: ...Mount the battery cover into the main unit with 2 screws Check the polarity of the batteries and the marks inside the battery compartment Insert the batteries Push the battery cover and main unit back in place IR EXTENDER OPERATIONS CAUTION battery and power adaptor safety Use new batteries of the recommended type and size only Never mix used and new batteries together To avoid chemical leaks remo...

Page 9: ...04 01 PROG Button Learning andLED indication 02 Temperature sensor 03 Battery Chassis 04 USB Power 5V DC 05 External IR port 06 Surround IR Output for top and 4 directions 06 09 IR EXTENDER QUICK INSTALLATION GUIDE www zipato com m ...

Page 10: ...successful please repeat the procedure 03 User can use either primary controller or secondary controller should support configuration command class to setup the ZXT 120 AC code by the parameter 27 IR code number for built in code library please refer to code list for the parameter value then setup your AC control code 04 Once the configuration and setup were completed the controller can use Z Wave...

Page 11: ... 0 22 0x00 0x16 26 0X1A Learning status register Note The status value 0x01 and 0x04 will be reset to 0 when the ZXT 120 receive a get command to this parameter 0 0x00 Idle this IR channel is idle default 1 0x01 OK the latest learning process successful and completed 2 0x02 Learning the ZXT 120 is busy processing previous learning request 4 0x04 Failed the latest learning request failed 27 0X1B IR...

Page 12: ...3 0x21 AC function SWING control 0 0x00 SWING OFF 1 0x01 SWING AUTO Default 35 0x23 Learn location status Bit mask 1 learn location has learn data Otherwise Bit mask 0 See figure Learn location as below 7 6 5 4 3 2 1 0 1 0 0 0 0 0 1 0 7 6 5 4 3 2 1 0 0 0 0 1 0 0 0 1 7 6 5 4 3 2 1 0 0 0 0 0 0 0 1 7 6 5 4 3 2 1 0 Bit Mask Byte 1 Location 0 7 Bit Mask Byte 2 Location 8 15 Bit Mask Byte 3 Location 16 ...

Page 13: ...ermostat mode Off 0x00 BASIC set Value 0xFF will map to Thermostat mode Resume 0x05 LISTENING MODE CHANGE DEFAULT MODE IS FLIRS ZXT 120canbeconfiguredaseither FrequentlyListeningRoutingSlaves FLiRS ifyou are using battery or Always Listening if you are using 5Vdc adaptor before inclusion process Refer to Glossary for definition of FLiRS and Always Listening node Important It is not allowed to chan...

Page 14: ...es four times then stays off ZXT 120 set in Always Listening mode Inclusion Exclusion Step Setup Key LED Indication Status on ZXT 120 1 Refer to your primary controller instructions to process the inclusion exclusion setup procedure 2 When prompted by your primary controller click once on the PROG button LED flashes once then stay off ZXT 120 will report the supported command class The primary con...

Page 15: ...perature set If the air conditioner does not respond to the command you set on Gateway Cool Heat Auto Temperature set etc repeat step 2 and 3 to select the next code on code list LED flashes once every time it receives a command from gateway Important Information Different brand or model of air conditioner has different function For example some air conditioner only support temperature set from 18...

Page 16: ...LED flashes twice when ZXT 120 receives the configuration setting 2 Look up below mapping table value 0 22 for learning and decide the IR setting you intent to learn next For example 22 C cool which matches value 5 IR code to be learnt will locate at 5 in ZXT 120 Set your original air conditioner remote at 22 C cool and turn it off Besides temperature and mode you may set other desired settings su...

Page 17: ...unter problem check followings Make sure your original remote is switched to power off Press the key on original remote before learning mode timeout Keep away from incandescent light and direct sunlight during learning Make sure IR Transmitter of your original remote alight with learning diode of ZXT 120 you may also slight adjust closer or further away the distance of two devices Some of remotes ...

Page 18: ...6 F cool 8 25 C cool 77 or 78 F cool 9 26 C cool 79 or 80 F cool 10 27 C cool 81 or 82 F cool 11 28 C cool 83 or 84 F cool 12 19 C heat 67 F heat 13 20 C heat 68 or 69 F heat 14 21 C heat 70 or 71 F heat 15 22 C heat 72 or 73 F heat 16 23 C heat 74 or 75 F heat 17 24 C heat 76 F heat 18 25 C heat 77 or 78 F heat 18 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com ...

Page 19: ...5 C at 11pm Just make sure the set code is learnt The learning mapping table is for split air conditioner which remote control is with LCD display For window type air conditioner which remote control is without LCD display the mapping table with temperatures do not apply due to different type of IR control protocol However user may still use the OFF or ON RESUME DRY key for learning Because the PO...

Page 20: ... fire or electrical shock Do not mount in locations with high humidity or large amounts of dust Doing so could cause a fire or electrical shock Do not mount to locations subject to high temperatures high humidity or exposure to water Doing so could cause a fire or electrical shock Do not mount to locations subject to large amounts of vibration large jolts or large forces These could cause an injur...

Page 21: ... sticks out from the wall edge It could get hit by people s bodies or objects and cause an injury Supplier will not be liable for any accidents or injuries that occur due to improper mounting or handling When mounting be careful not to get your fingers pinched or injure your hands MOUNTING PROCEDURE PRECAUTIONS The ZXT 120 can be mounted to a wall or wooden racks using the two key holes in the bot...

Page 22: ...ng the screws to the wall leave a space between the wall and screw cap as shown in the figure 4 5 mm 3 1ins 48 5 mm 1 7 8ins 3 Insert the ZXT 120 key holes onto the two screws mounted to the wall and then slide downward to secure in place 4 After securing the ZXT 120 to the wall connect the USB Power or batteries and IR emitter cable to the ZXT 120 22 IR EXTENDER QUICK INSTALLATION GUIDE w www zip...

Page 23: ...es and IR emitter cable so that they are firmly connected to the ZXT 120 5 When removing the ZXT 120 from the wall lift up the ZXT 120 then pull it towards you 6 Detach the main unit from the battery chassis by move toward to top position 23 IR EXTENDER QUICK INSTALLATION GUIDE www zipato com m ...

Page 24: ...e of 20m by up to 20 to 30 Plasterboard and wooden walls block less of the radio signal then concrete brick or tile walls which will have more of an effect on signal strength Wall mounted Z Wave devices will also suffer a loss of range if they are housed in metal junction boxes which could also reduce the range by up to 20 to 30 MAINTENANCE Do not expose your ZXT 120 to dust strong sunlight humidi...

Page 25: ...Z Wave controller or gateway that has control capability for Thermostat devices All Z Wave products also come with the Z Wave logo Can I use the USB port to configure ZXT 120 No the mini USB port only provides an alternative option for user to power the ZXT 120 Do I need an electrician to install Z Wave products in my house Installation can be simple In some cases all you need to do is mount the Z...

Page 26: ...le value normal or high power mode or adjust the position of your external IR emitter Can I use 2 or more ZXT 120 in my house What is the max units if yes Yes and it is very depend on the capability of gateway controller For example gateway can supports up to 8 16 or 32 ZXT 120 in a network How to avoid the IR interference if I am using 2 identical air conditioners in same location but want to con...

Page 27: ...0 40 C Report resolution 1 degree C Operation 0 40 C Storage 20 60 C POWERED BY USB Power DC 5V 100mA or Dry battery AAA x 3pcs RF OPERATING DISTANCE up to 80ft outdoor line of sight in unobstructed environment IR OPERATING DISTANCE up to 25ft line of sight in unobstructed environment IR LEARNING Max 23 commands DIMENSION Dia 70mm T 18mm Main unit Dia 70mm T 15 5mm Battery chassis SPECIFICATIONS 2...

Page 28: ...upported COMMAND_CLASS_THERMOSTAT_MODE Version2 No Yes COMMAND_CLASS_THERMOSTAT_SETPOINT Version2 No Yes COMMAND_CLASS_THERMOSTAT_FAN_MODE Version2 No Yes COMMAND_CLASS_BATTERY Version1 No Yes COMMAND_CLASS_CONFIGURATION Version1 No Yes COMMAND_CLASS_BASIC Version1 No Yes COMMAND_CLASS_VERSION Version1 No Yes COMMAND_CLASS_SENSOR_MULTILEVEL Version1 No Yes COMMAND_CLASS_SWITCH_ALL Version1 No Yes ...

Page 29: ...hermostat Fan mode Auto Auto Low Yes Low Yes Auto High Yes High Yes Auto Medium Yes Medium Yes Thermostat Set point Heating Yes Cooling Yes Furnace No Dry Air Yes Moist Air No Auto changeover Yes Energy Save heating No Energy Save cooling No Away heating No Thermostat Mode Off Yes Heat Yes Cool Yes 29 IR EXTENDER QUICK INSTALLATION GUIDE www zipato com m ...

Page 30: ... AND PARAMETERS SUMMARIES FUNCTIONS AIR CONDITIONER FUNCTION Z WAVE COMMAND CLASS Z WAVE COMMAND COMMAND PARAMETER POWER POWER ON COMMAND_CLASS_ THERMOSTAT _MODE THERMOSTAT_ MODE_SET MODE 5 COMMAND_CLASS_ BASIC BASIC_SET VALUE 0XFF POWER OFF COMMAND_CLASS_ THERMOSTAT _MODE THERMOSTAT_ MODE_SET MODE 0 COMMAND_CLASS_ BASIC BASIC_SET VALUE 0X00 30 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com...

Page 31: ...S_ THERMOSTAT _MODE THERMOSTAT_ MODE_SET MODE 8 AUTO Changeover COMMAND_CLASS_ THERMOSTAT _MODE THERMOSTAT_ MODE_SET MODE 10 HEAT mode Temperature SETPOINT TYPE 1 TEMPERATURE VALUE COOL mode Temperature SETPOINT TYPE 2 TEMPERATURE VALUE DRY mode Temeprature SETPOINT TYPE 8 TEMPERATURE VALUE AUTO mode Temperature SETPOINT TYPE 10 TEMPERATURE VALUE TEMPERATURE SETTING COMMAND_CLASS_ THERMOSTAT _SETP...

Page 32: ... O D E _ SET FAN MODE 1 FAN MID 2 3 COMMAND_CLASS_ THERMOSTAT _FAN_MODE v2 THERMOSTAT_ FA N _ M O D E _ SET FAN MODE 5 FAN HIGH 3 3 COMMAND_CLASS_ THERMOSTAT _FAN_MODE v1 THERMOSTAT_ FA N _ M O D E _ SET FAN MODE 3 COMMAND_CLASS_ THERMOSTAT _FAN_MODE v2 THERMOSTAT_ FA N _ M O D E _ SET FAN MODE 3 SWING ON SWING AUTO COMMAND_CLASS_ CONFIGURATION CONFIGURATIO N_SET PARAMETER NO 33 SIZE 1 VALUE 1 SWI...

Page 33: ...UE 0xFF DISABLE COMMAND_CLASS_ CONFIGURATION CONFIGURATIO N_SET PARAMETER NO 32 SIZE 1 VALUE 0 ENABLE COMMAND_CLASS_ CONFIGURATION CONFIGURATIO N_SET PARAMETER NO 32 SIZE 1 VALUE 0xFF BATTERY LEVEL COMMAND_CLASS_ BATTERY BATTERY_GET VERSION COMMAND_CLASS_ VERSION VERSION_GET MANUF ER SPECIFIC COMMAND_CLASS_ M A N U FA C T U R E R _ SPECIFIC MANUFACTURER_ SPECIFIC_GET IR TRANS MISSION POWER LEVEL F...

Page 34: ...ericool 430 Apton 67 Ariagel 13 Aucma 413 414 Aux 189 407 21 190 398 399 Azure 424 Beaver 184 Carrier 108 109 112 88 96 97 98 99 100 101 102 103 104 105 106 107 110 111 396 397 431 Chang Hong 178 179 180 5 121 122 123 124 125 126 127 134 135 136 148 Chigo 186 42 57 58 Chuanhua 37 113 TEMPERA TURE SENSOR 34 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com ...

Page 35: ...211 290 325 29 162 163 261 264 265 267 31 33 266 268 269 5270 366 289 Delonghi 13 46 91 Ecoair 42 Elco 432 Electra 432 433 465 466 467 Electrolux 55 295 297 Elsonic 81 Emailair 34 153 Fedders 276 Frigidaire 273 274 275 Fujitsu 16 199 200 201 202 55 27 34 203 204 205 206 227 158 159 160 161 Galanz 4 70 83 86 277 381 35 IR EXTENDER QUICK INSTALLATION GUIDE www zipato com m ...

Page 36: ...7 208 209 257 197 Heran 421 Hisene 68 80 382 9 427 10 Hitachi 52 53 120 227 258 259 260 291 298 299 472 39 50 51 255 262 263 375 436 Hualing 37 56 70 193 Huifeng 113 INYCIN 70 Kang Li 43 Kelon 411 12 13 14 143 Kelvinator 46 87 17 Kolin 44 Komeco 46 88 Konka 42 70 Lennox 15 18 69 LG 464 91 17 81 82 294 36 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com ...

Page 37: ...0 231 233 234 235 236 237 238 239 240 315 326 392 35 37 57 93 153 287 70 Mitsubishi Heavy Industries 36 42 184 243 250 20 38 113 114 115 116 117 118 119 131 132 133 164 165 251 252 253 254 278 306 316 317 319 322 Natinal 369 402 211 NEC 127 128 129 130 135 136 137 138 139 140 141 142 146 147 148 152 166 167 168 169 170 Neo 186 Panasonic 64 95 183 191 368 323 47 61 62 63 65 92 241 242 365 378 379 4...

Page 38: ...7 148 152 166 167 168 169 170 187 218 Schnerider Elecric 42 Shangling 70 SHARP 90 318 426 8 192 213 143 144 145 157 212 214 215 216 217 193 7 66 Shinco 22 85 Shining 70 Siemens 46 Springer 88 Super General 57 Surrey 55 Tadiran 40 46 48 54 471 TCL 24 380 434 Teco 426 TONAL 188 Tornado 40 46 48 38 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com ...

Page 39: ...3 224 225 226 219 71 Toyo 42 Toyo Cool 42 Trane 69 3 173 174 Videocon 186 VOLTAS 4 377 46 Westpoint 88 Whirlpool 13 211 271 272 White Westinghouse 395 Xileng 150 YORK 18 15 55 89 296 Yutu 70 39 IR EXTENDER QUICK INSTALLATION GUIDE www zipato com m ...

Page 40: ...PLIED INCLUDING ANY IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ZIPATO EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY ANY IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED IN DURATION TO THE LIMITED WARRANTY PERIOD TO THE EXTENT ALLOWED BY LOCAL LAW THE REMEDIES IN THIS WARRANTY STATEMENT ARE CUSTOMER S SOLE AND EXCLUSIVE REMEDIES AGAI...

Page 41: ...LIMITATIONSOFTHISLIMITEDWARRANTYMAY NOT APPLY TO YOU THIS LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS THAT MAY VARY FROM STATE TO STATE OR FROM COUNTRY TO COUNTRY YOU ARE ADVISED TO CONSULT APPLICABLE STATE OR COUNTRY LAWS FOR A FULL DETERMINATION OF YOUR RIGHTS This Limited Product Warranty applies to ZIPATO branded hardware products collectively referred to as...

Page 42: ...se are free from material defects in materials and workmanship during the Limited Product Warranty Period set forth below Limited Product Warranty Period if the product is used and serviced in accordance with the user manual and other documentation provided to the purchaser at the time of purchase or as amended from time to time ZIPATO does not warrant that the products will operate uninterrupted ...

Page 43: ...t is your proof of the purchase date You may be required to provide proof of purchase as a condition of receiving warranty service You are entitled to warranty service according to the terms and conditions of this document if a repair to your ZIPATO branded hardware is required within the Limited Product Warranty Period Other than in respect of products for domestic use in particular those listed ...

Page 44: ...CT TYPE Product Warranty Period IR EXTENDER One 1 year IMPORTANT The content of Product Type listed above is subject to change please refer to the www zipato com for latest update 44 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com ...

Page 45: ...are replaced under this Limited Product Warranty become the property of ZIPATO The replacement part or product takes on the remaining Limited Warranty Period of the replaced part or product The replacement product need not be new or of an identical make model or part ZIPATO may in its discretion replace the defective product or any part thereof with any reconditioned equivalent or superior product...

Page 46: ... with the e applicable requirements of the following documents EN 300 220 2 EN 60950 1 EN 301 489 1 EN 301 489 3 EN 62479 I hereby declare that the equipment named above has been designed to comply with the relevant sections of the above referenced specifications The unit complies with all applicable Essential Requirements of the Directives PERSON RESPONSIBLE FOR THIS DECLARATION Dean Janacek Cert...

Page 47: ... exploitation est autorisée aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radioélectrique subi même si le brouillage est susceptible d en compromettre le fonctionnement NOTE Changes or modifications not expressly approved by Zipato for compliance could void the user s authority to operate the equipment T...

Page 48: ...does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to w...

Page 49: ...local authorities some will accept your product for free or simply drop it off at your Zipato re seller store By recycling the product and its packaging in this manner you help to conserve the environment and protect human health At Zipato we understand and are committed to reducing any impact our operations and products may have on the environment To minimize this impact Zipato designs and builds...

Page 50: ...NOTES 50 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com ...

Page 51: ...51 IR EXTENDER QUICK INSTALLATION GUIDE www zipato com m ...

Page 52: ...52 IR EXTENDER QUICK INSTALLATION GUIDE w www zipato com make your home smart www zipato com ...