 802261 - Residential HT- CO Installation Instructions - March 2016 -  V3.00 

Page 1 of 16

Zip HydroTap G4

          Installation Instructions

Affix Model Number Label 

Here

 802261

Filtered Chilled drinking water for residential kitchens and tea rooms.

®

Summary of Contents for 802261

Page 1: ...ial HT CO Installation Instructions March 2016 V3 00 Page 1 of 16 Zip HydroTap G4 Installation Instructions Affix Model Number Label Here 802261 Filtered Chilled drinking water for residential kitchen...

Page 2: ...interchangeable taps to suit the customer s needs See options below For ease of installation it is recommended to fit the tap before installing the undersink unit The installation procedure for each o...

Page 3: ...ion Instructions STEP 1 Measure and cut all the tap holes before fitting the taps Section 1 Tap Installation instructions 1 HydroTap Tap installation 8 STEP 2 Check for adequate ventilation Section 2...

Page 4: ...ard supporting the appliance is adequate for the total weight of the appliance when full of water Before Commissioning 1 Check the unit has been installed correctly 2 Check all plumbing fittings have...

Page 5: ...a conventional refrigerant compressor to chill the water which is factory set to 6 10 C These units are NOT designed to be used for sanitary fixtures The water filter is a disposable item which will r...

Page 6: ...persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and un...

Page 7: ...tap shown 1 off HydroTap Undersink Unit with water filter 1 off Mains water connection hose 1 x Inlet vent 1 x Outlet vent 9 x Screws 1 x User guide 1 x Installation Instructions 1 x Tee piece for Ce...

Page 8: ...es and positioned so that the connection point and the stop cock will not be obstructed when the undersink units are installed A cold water supply with a minimum working pressure of 172kPa and a maxim...

Page 9: ...ement is for a 50mm air gap either side and 300mm above of the undersink unit It is important that the 4mm door buffers For all installations are fitted to the inside edge of the cupboard door to allo...

Page 10: ...sary to fit a standard HydroTap vent kit which ensures heat dissipation through natural convection via installed vents For high use applications where the cupboard space temperature is near 35 C or hi...

Page 11: ...ndersink Unit Installation BLUE BRAIDED 3 1 Hose and tube fitting Do not overtighten Remove all caps from the top of the undersink unit Install the mains water braided hoses to the undersink unit befo...

Page 12: ...size They must have a constant fall back to the unit BLUE BRAIDED Note Mains hose length is 750mm Plug and Cord length is 1800mm Position the under sink unit close to the outlet tap within reach of th...

Page 13: ...ow at least 10 litres of water to flush through the filter 4 Once the filter flush is finished Turn the stop cock OFF then press Stop to end filter flush mode Have a 10L bucket or similar container no...

Page 14: ...too Hot Check ventilation Water Supply Failure No water Check water supply is turned ON Cold Sensor Open Internal fault Call Zip Service Cold Sensor Closed Internal fault Call Zip Service Flood Senso...

Page 15: ...ation Instructions March 2016 V3 00 Page 15 of 16 In order to help preserve our environment we ask that you dispose of this product correctly Please contact your local city council for collection cent...

Page 16: ...49 US5103859 US5099825 and SA2006 08043 Other patents are in force and patent applications are pending Head Office Zip Heaters Aust Pty Ltd ABN 46 000 578 727 67 Allingham Street Condell Park NSW 2200...