background image

© Zennio Avance y Tecnología S.L. 

Edition 8 

Futher information 

www.zennio.com

 

Page 1/2 

 

Z41 Pro 

Capacitive color touch panel with IP connection 

ZVI-Z41PRO 

TECHNICAL DOCUMENTATION 

 

FEATURES 

 

4.1’’ capacitive color touch panel 

 

16 million color LCD display 

 

Up to 12 configurable pages 

 

Up to 96 configurable direct control and/or indicator functions 

 

2 independent thermostats 

 

2 analog/digital inputs 

 

Customized device orientation (Vertical or Horizontal) 

 

Built-in temperature sensor 

 

Real Time Clock (RTC) with watch battery and NTP support 

 

External 12-29VDC power supply 

 

Integrated KNX BCU 

 

Mini-USB and Ethernet connection 

 

Magnetic fit 

 

Complete data saving in case of power failure 

 

Conformity with the CE directives (CE-mark on the back side) 

 

 

 

1. Temperature probe

 

2. KNX connector

 

3. Input connector

 

4. Battery

 

5.Programming button

 

6. Programming LED

 

7. Ethernet connector

 

8. Magnet

 

9. Mini-USB connector

 

10. External power supply connector

 

Figure 1: Z41 Pro 

Programming button: short press to set programming mode. If this button is held while plugging the device into the KNX bus, it enters the safe mode. 
 
Programming LED: programming mode indicator (red). When the device enters the safe mode, it blinks (red)  every half second. During the start-up 
(reset or after KNX bus failure) and if the device is not in safe mode, it emits a red flash. 

GENERAL SPECIFICATIONS 

CONCEPT 

DESCRIPTION 

Type of device 

Electric operation control device 

KNX supply 

Voltage (typical) 

29VDC SELV 

Voltage range 

21..31VDC 

Maximum 
consumption 

Voltage 

mA 

mW 

29VDC (typical) 

174 

24VDC¹ 

10 

240 

Connection type 

Typical TP1 bus connector  for 0.80mm Ø rigid cable 

External power supply 

12-  29  VDC.  Maximum  consumption:  250mA  (12VDC),  112mA  (24VDC), 
86mA (29VDC). Do not connect 29VDC KNX bus as external power supply 

Operation temperature 

5°C .. +45°C 

Storage temperature 

-20°C .. +55°C 

Operation humidity 

5 .. 95% 

Storage humidity 

5 .. 95% 

Complementary characteristics 

Class B 

Protection class 

III 

Operation type 

Continuous operation 

Device action type 

Type 1 

Electrical stress period 

Long 

Degree of protection 

IP20, clean environment 

Installation 

Portrait or landscape position, with the temperature sensor at the bottom or 
right, respectively. Magnetic fit. See Installation instructions section. 

Minimum clearances 

Please, keep away  from heat and cold air flows to get better temperature 
measurements. 

Response on KNX bus failure 

Data saving according to parameterization. Initialization screen. 

Response on KNX bus restart 

Data recovery according to parameterization 

Response on power supply failure 

Complete data saving. Display is switched off 

Response on power supply recovery 

Current data recovery 

Operation indicator 

Several on display as programmed 

Accessories 

RJ45 cable connector (included). Mini USB A-B cable Ref. ZN1AC-UPUSB 
(not included) 

Weight 

237g (Al) / 226g (PC) 

PCB CTI index 

175V 

Housing material 

PC+ABS FR V0 halogen free 

¹ Maximum consumption in the worst-case scenario (KNX Fan-In model). 

 

 

1

 

2

 

3

 

4

 

5

 

6

 

7

 

8

 

9

 

10

 