background image

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tecla XL

 

 

PC-ABS Capacitive push button with 4/6/8/10 buttons and 

custom icons 

 
 

ZVITXLX4 / ZVITXLX6 / ZVITXLX8 / ZVITXLX10 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

U

S

E

R

 M

A

N

U

A

L

 

  

 

 

Application Programme Version:

 

[1.7]

  

 User Manual Version: [1.7]_a

 

 

 

 

www.zennio.com

 

 

 

Summary of Contents for Tecla XL X10

Page 1: ...Tecla XL PC ABS Capacitive push button with 4 6 8 10 buttons and custom icons ZVITXLX4 ZVITXLX6 ZVITXLX8 ZVITXLX10 USER MANUAL Application Programme Version 1 7 User Manual Version 1 7 _a www zennio com ...

Page 2: ...3 1 2 Installation 5 1 3 Start Up and Power Loss 6 2 Configuration 7 2 1 General 7 2 1 1 Configuration 7 2 1 2 Temperature Sensor 10 2 1 3 Backlight 10 2 1 4 Sounds 10 2 1 5 Ambient Luminosity Sensor 10 2 1 6 Proximity Sensor 10 2 1 7 Advanced Configuration 11 2 2 Buttons 11 2 3 Thermostat 11 ANNEX I Communication Objects 12 ...

Page 3: ...y of buttons is complemented by an internal temperature sensor and a thermostat function as well as an elegant design with fully customisable backlit icons The most outstanding features of Tecla XL are Fully customisable backlit icons 4 6 8 10 touch buttons which can operate as individual or pair controls Horizontally or vertically oriented configuration Light indicator LED for every button Buzzer...

Page 4: ...Tecla XL https www zennio com Technical Support https support zennio com 4 Proximity sensor for quick start Thermostat function Heartbeat or periodical still alive notification ...

Page 5: ...mming LED 4 will then light in red On the contrary if this button is held while the device gets connected to the bus the device will enter the safe mode In such case the programming LED will blink in red colour For detailed information about the technical features of Tecla XL as well as on security and installation procedures please refer to the device Datasheet bundled within the device packaging...

Page 6: ...out 2 minutes without performing any action in order to make it possible a proper calibration of Proximity sensor Luminosity sensor Button presses For a correct calibration of the proximity and brightness sensors it is recommended not to remain too close or place anything less than 50cm approximately and do not hit with direct light to the device during this time ...

Page 7: ...oject the configuration process begins by entering the Parameters tab of the device 2 1 GENERAL In order to allow the device to perform the desired functions a number of options must be parameterized either related to its general behaviour or to advanced features 2 1 1 CONFIGURATION In the Configuration tab the general settings are displayed ETS PARAMETERISATION Figure 2 Main configuration ...

Page 8: ...s on the middle Figure 3 Orientation Buttons enabled read only parameter to make it evident that the Buttons tab is always enabled in the tab tree on the left See section 2 2 for details Thermostat disabled enabled enables or disables the Thermostat tab in the tree on the left See section 2 3 for details Heartbeat Periodic Alive Notification disabled enabled incorporates a one bit object to the pr...

Page 9: ...left See section 2 1 2 for details Sounds Default Custom sets whether the sound functions button beeps alarm and doorbell should work according to the pre defined configuration or to a user defined configuration See section 2 1 4 for details Ambient luminosity sensor disabled enabled enables setting the ambient luminosity sensor When the sensor is enabled a new tab for its configuration is shown S...

Page 10: ...zennio com for detailed information about the functionality and the configuration of the related parameters 2 1 4 SOUNDS For detailed information about the functionality and the configuration of the related parameters please refer to the specific manual Capacitive Touch Switches available in the Tecla XL product section at the Zennio homepage www zennio com 2 1 5 AMBIENT LUMINOSITY SENSOR Capaciti...

Page 11: ...iled information about the functionality and the configuration of the related parameters please refer to the specific manual Capacitive Touch Switches available in the Tecla XL product section at the Zennio homepage www zennio com 2 3 THERMOSTAT Capacitive touch switches implement one Zennio thermostat which can be enabled and fully customised Please refer to the specific manual Zennio Thermostat ...

Page 12: ...1 Run Save Scene 1 64 6 1 Bit I C W DPT_Enable 0 1 General Touch Locking 0 Unlock 1 Lock 1 Bit I C W DPT_Enable 0 1 General Touch Locking 0 Lock 1 Unlock 7 1 Bit C T DPT_Switch 0 1 General Welcome Back Object Switch Object Sent on Wake Up 8 1 Bit I C W DPT_Enable 0 1 General Sounds Disabling Button Sound 0 Disable Sound 1 Enable Sound 1 Bit I C W DPT_Enable 0 1 General Sounds Disabling Button Soun...

Page 13: ... Off Short Press Switch Between On and Off 1 Bit C T DPT_Step 0 1 Btn Ix Shutter Stop Step Short Press 0 Stop Shutter Step Up 1 Stop Shutter Step Down 1 Bit C T DPT_Trigger 0 1 Btn Ix Shutter Stop End Pressing Stop Shutter 25 31 37 43 49 1 Bit C T DPT_Switch 0 1 Btn Ix Light On Short Press Send On 1 Bit C T DPT_Switch 0 1 Btn Ix Light Off Short Press Send Off 25 31 37 43 49 55 61 67 73 79 1 Bit C ...

Page 14: ...T_Scaling 0 100 Btn Ix Shutter Position 0 100 1 Byte I C W T DPT_Scaling 0 100 Btn Ix Light Dimming Status 0 100 1 Byte I C W T 1 xxx 0 1 Btn Ix Room State 0 Normal 1 Make up Room 2 Do not Disturb 30 36 42 48 54 60 66 72 78 84 1 Byte I C W T DPT_Value_1_Ucount 0 255 Btn Ix Two Objects Long Press 1 Byte Send Selected 1 Byte Value on Long Press 85 91 97 103 109 1 Bit I C W T DPT_Switch 0 1 Btn Px Sw...

Page 15: ...PT_Switch 0 1 Btn Px Two Objects Short Press Lower 0 Upper 1 1 Bit I C W T DPT_Switch 0 1 Btn Px Two Objects Short Press Lower 1 Upper 0 86 92 98 104 110 4 Bit I C W T DPT_Control_Dimming 0x0 Stop 0x1 Dec by 100 0x7 Dec by 1 0x8 Stop 0xD Inc by 100 0xF Inc by 1 Btn Px Light Dimming Long Press Left Darker Right Brighter 4 Bit I C W T DPT_Control_Dimming 0x0 Stop 0x1 Dec by 100 0x7 Dec by 1 0x8 Stop...

Page 16: ... 94 100 106 112 1 Bit I C W T DPT_Switch 0 1 Btn Px LED On Off 0 On 1 Off 1 Bit I C W T DPT_Switch 0 1 Btn Px LED On Off 0 Off 1 On 89 95 101 107 113 1 Byte I C W T DPT_Scaling 0 100 Btn Px Light Dimming Status 0 100 115 1 Byte I C W DPT_SceneControl 0 63 128 191 Thermostat Scene Input Scene Value 116 2 Bytes I C W T U DPT_Value_Temp 273 00º 670433 28º Tx Temperature Source 1 External Sensor Tempe...

Page 17: ... T DPT_Heat_Cool 0 1 Tx Mode Status 0 Cool 1 Heat 136 1 Bit I C W DPT_Switch 0 1 Tx On Off 0 Off 1 On 137 1 Bit O C R T DPT_Switch 0 1 Tx On Off Status 0 Off 1 On 138 1 Bit I O C R W DPT_Switch 0 1 Tx Main System Cool 0 System 1 1 System 2 139 1 Bit I O C R W DPT_Switch 0 1 Tx Main System Heat 0 System 1 1 System 2 140 1 Bit I C W DPT_Enable 0 1 Tx Enable Disable Secondary System Cool 0 Disable 1 ...

Page 18: ... 18 162 2 Bytes O C R T DPT_Value_Temp 273 00º 670433 28º Internal Probe Current Temperature Temperature Sensor Value 163 1 Bit O C R T DPT_Alarm 0 1 Internal Probe Overcooling 0 No Alarm 1 Alarm 164 1 Bit O C R T DPT_Alarm 0 1 Internal Probe Overheating 0 No Alarm 1 Alarm ...

Page 19: ...in and send us your inquiries about Zennio devices https support zennio com Zennio Avance y Tecnología S L C Río Jarama 132 Nave P 8 11 45007 Toledo Spain Tel 34 925 232 002 www zennio com info zennio com ...

Reviews: