background image

-  1  -

 

 
 
 
 
 
 
 
 
 

    ZS-6822  Series     

    LAN/DIO  Adapter

     

 

User’s Manual

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Zenisu Keisoku,Inc.

 

Zip code: 183-0027 

2-13-37, Honmachi, Fuchu, Tokyo, Japan 

TEL: +81-(0)42-368-2126 
FAX: +81-(0)42-364-0067 

URL 

http://www.zenisu.co.jp/

 

Summary of Contents for ZS-6822

Page 1: ...1 ZS 6822 Series LAN DIO Adapter User s Manual Zenisu Keisoku Inc Zip code 183 0027 2 13 37 Honmachi Fuchu Tokyo Japan TEL 81 0 42 368 2126 FAX 81 0 42 364 0067 URL http www zenisu co jp...

Page 2: ...4 3 IP Address setting of ZS 6822 7 5 COM Port Redirector for Win32 10 5 1 COM Port Redirector for Win32 10 5 2 Virtual COM port setting 14 6 Operation 18 6 1 Transfer data method 18 6 2 Control signa...

Page 3: ...can be selected for each port In addition to data control lines are prepared so that it can be synchronized with external device 3 Specification 3 1 Operation environment Equipment with LAN port 3 2...

Page 4: ...lt in type Data connector 50 core flat cable 50 core flat cable Power supply DC4 75V to 5 25V 100mA or less DC4 75V to 5 25V 100mA or less Environment Temperature 0 to 50 Humidity 85 or less Temperatu...

Page 5: ...of your network part as result of the ipconfig command In this example the network part is 192 168 1 The host part numbers are unused numbers To determine the IP address of ZS 6822 the network part of...

Page 6: ...822 3 Assume that the address determined in the above 192 168 1 33 and MAC address is 00 20 4A 98 27 4F Run the command prompt MS DOS prompt on the PC and set the temporary IP address This work is set...

Page 7: ...mpt enter the following command and execute it e g telnet 192 168 1 33 1 An error message such as Can not connect to host is displayed but disregard this message 2 At the command prompt enter the foll...

Page 8: ...isplayed Please press the return key If you leave it without pressing the return key a message such as The connection with the host has been disconnected is displayed and telnet will be ended 3 The fo...

Page 9: ...be prompted to enter an IP address Enter the IP address of ZS 6822 decided in the above IP Address setting here 5 Since Your choice will be displayed again enter 9 and save the IP address setting valu...

Page 10: ...director for Win32 made by Rantronix inc 5 1 COM Port Redirector for Win32 1 Whe you execute CprDotNetDL 4 1 0 2_Web exe in the folder LANTRONIX folder on the CD ROM the following screen will be displ...

Page 11: ...11 2 When NET Framework 2 0 is not installed the following screen will be displayed Click Accept button 3 The following screen will be displayed Download and installation will be started...

Page 12: ...12 4 The following screen will be displayed and click the NEXT button 5 The following screen will be displayed If there is no change in the place to save click the NEXT button...

Page 13: ...13 6 The following screen will be displayed please click NEXT button 7 The following screen will be displayed There is a notice message but click the Continue button...

Page 14: ...following screen will be displayed Click the Close button Installation of the program is completed 5 2 Virtual COM port setting 1 From the start menu select Program Lantronix CPR 4 1 CPR Manager and...

Page 15: ...wing screen will be displayed On this screen check the port number to be set as the virtual COM port and press the OK button 3 Com New will be added Select it and set Host and TCP Port Please set the...

Page 16: ...16 4 After setting is completed select Com Port Save setting The following screen will be displayed click Yes button Click Continue button...

Page 17: ...17 The following screen will be displayed Setting is completed Please close this application...

Page 18: ...nsferred in ASCII code and one character is converted to 4 bit binary code bit binary LAN Data 8 4 2 1 HEX 0 0 0 0 0 0 0 0 1 1 0 0 1 0 2 0 0 1 1 3 0 1 0 0 4 0 1 0 1 5 0 1 1 0 6 0 1 1 1 7 1 0 0 0 8 1 0...

Page 19: ...D0 C D 1 2 3 4 ZS 6822 Input Output 0123 ABCD 6 2 Control signal A control signal is prepared so that it can be synchronized with the connected equipment Signal Direction Description STB OUT The adapt...

Page 20: ...d data 1 3 2 4 Output port_3 High Low High Low Output port_4 STB output 1 2 3 4 Pulse output Data is set 4 bits to the port set as output after receiving data from the PC The output port data is outpu...

Page 21: ...input For example if the number of input ports is set to 4 8bytes of data will be sent from ZS 6822 when R command is executed Format R CR LF Return value xxxx CR LF Data as same as the number set fo...

Page 22: ...when turn on the power of ZS 6822 Format Dxxxx CR LF Set in the order of port_1 port_2 port_3 port_4 after D x is I for IN for input O for OUT for output Return value OK CR LF Setting is completed NG...

Page 23: ...ut when turning on the power of ZS 6822 Set the pulse width at pulse output use the P command Format U CR LF x is number 0 continuous output 1 pulse output Return value OK CR LF Setting is completed N...

Page 24: ...PORT D3 23 24 D3 PORT D4 25 26 D4 D5 27 28 D5 D6 29 30 D6 D7 31 32 D7 IN LAH 33 34 NC OUT STB 35 36 NC OUT TRG 37 38 NC OUT CLR 39 40 NC NC 41 42 GND NC 43 44 GND NC 45 46 GND NC 47 48 GND NC 49 50 G...

Page 25: ...ith instruction manual 2 It will be charged for extra in the following case even during warranty period Incorrect usage or failure or damage caused by carelessness Failure or damage caused by improper...

Reviews: