background image

 

 
DISTINGUISHING FEATURES OF THE PHANTOM 
 

 

Five (three - if EMP66G tube employed) readily available configurations of illuminated red-on-
green reticles that are able to be switched at a moment's notice 

 

Functions with one AA (1.5V) or CR-123 (3V) battery 

 

Accurate internal front lens focus adjustment 

 

Lightweight and highly durable; manufacturing employs carbon plastic and other modern 
technologies 

 

High magnification, 3x or 4x  

 

Close observational range of 5 meters 

 

IPX6 rating against water intrusion 

 

Shockproof with the use of heavy recoil ammunition (.375 H&H, .416 Rigby, .50 cal.) 

 

Vertical positioning of the battery ensures an uninterrupted power supply when firing 

 

The image intensifier tube is protected against excessive light exposure  

 

Incremental reticle brightness adjustment 

 

The reticle will blink as a warning 15-30 minutes before the device shuts down automatically as 
a low battery indicator  

 

Stabilized power supply for optimal consumption, ensuring no shift of the aiming point under a 
continuous power draw or drop in temperature 

 

Fast start-up 

 

Ergonomic design; the adjustment controls are 
located on top 

 

Precision internal windage/elevation adjustment 
MOA per click 

 

Built-in high-power PULSE hazard free IR 
illuminator with beam focus 

Summary of Contents for PHANTOM 26057T

Page 1: ...f heavy recoil ammunition 375 H H 416 Rigby 50 cal Vertical positioning of the battery ensures an uninterrupted power supply when firing The image intensifier tube is protected against excessive light exposure Incremental reticle brightness adjustment The reticle will blink as a warning 15 30 minutes before the device shuts down automatically as a low battery indicator Stabilized power supply for ...

Page 2: ... and hunting Patrolling and safeguarding Search and rescue GUIDELINES FOR OPERATION The PHANTOM has been designed for extensive usage To ensure longevity and performance it is necessary to adhere to the following Under illuminated conditions measuring more than 1 lux deep dusk do not power on the riflescope with the objective lens cap open and do not point the product towards a direct light source...

Page 3: ...target shooting To ensure reliable performance it is recommended to carry out regular technical inspections of the unit BATTERY INSTALLATION Unscrew the cap 1 of the battery compartment counter clockwise Install one AA 1 5V or CR 123 3V battery so that the and match the markings on the body of the unit Tighten the cap 1 OPERATING THE PHANTOM Install the batteries according to the directions in the...

Page 4: ... be turned on instantaneously with either the remote control housed in its bracket 10 or by button 11 SIGHTING IN THE PHANTOM Sighting in of the scope should be done at operating temperatures by following the order of these steps Mount the rifle with the scope installed on a scoped machine Make sure that no sources of light are visible through the scope s field of vision Set a target at a distance...

Page 5: ...he battery makes contact with metal Verify the proper function of the following selector switch 3 reticle brightness knob 4 reticle selector button and the instant power on button 11 Verify the smoothness of the objective lens focusing mechanism 6 diopter focusing knob 7 and the IR illuminator knob 8 TECHNICAL MAINTENANCE Technical maintenance should be done no less than twice a year and is compri...

Page 6: ...e diopter cannot be adjusted to your vision If you wear prescription glasses with a range of 5 keep glasses on when looking through the eyepiece Dust and moisture are covering the outside optical surfaces Clean the lens surfaces with a soft cotton tissue or cloth Moisture is on the inside of the objective and the eyepiece lenses or is on the optical surfaces of the electronic optical converter and...

Page 7: ... sighted in during the summer and is now being used in the winter or the other way around a small displacement of the aiming point is possible The scope does not focus Wrong settings Adjust the riflescope according to the instructions given in the section entitled OPERATING THE PHANTOM and check the surfaces of the eyepiece and objective lenses and clean them if necessary from dust condensation fr...

Reviews: