background image

IM 04L51B01-04Z1  page 1/2

User’s

Manual

IM 04L51B01-04Z1

Quick, Easy Steps

4th Edition : Dec. 2015

Connect I/O signals and power.

First Step Guide 

(IM 04L51B01-02EN)

“Installation and Wiring”

Install modules.

Not required 

if preinstalled

To connect an GX60, 

install the modules in 

the GX60.

Manuals for reference

First Step Guide 

(IM 04L51B01-02EN)

“Installation and Wiring”

URL: www.smartdacplus.com/manual/en/

Product user’s manuals can be downloaded or viewed at the 

following URL;

Make the GX/GP recognize the 

modules (GX/GP reconfiguration).

Configure signal inputs.

Configure functions as 

necessary.

Turn on the power.

Set the date and time.

First Step Guide 

(IM 04L51B01-02EN)

“Basic Operations”

First Step Guide 

(IM 04L51B01-02EN)

“Reconfiguring the 

GX/GP”

First Step Guide 

(IM 04L51B01-02EN)

“Basic Operations”

First Step Guide 

(IM 04L51B01-02EN)

“Basic Operations”

First Step Guide 

(IM 04L51B01-02EN)

“Basic Operations”

Start measuring/recording.

Paperless Recorder

User’ s Manual  

(IM 04L51B01-01EN)

Dummy covers are 

attached to empty slots 

(with screws).

Modules (seven types)

GX10/GP10: Up to 3 modules can be installed.

GX20/GP20: Up to 10 modules can be installed.

Lit in red

Alarm activated

Off: Power off

Lit in blue

Running

(No alarm)

Alternates

If preinstalled, modules are preconfigured. 

If you rearrange the modules  or connect an 

GX60, reconfigure.

Modules not installed

Insert until a click is heard

and fasten with screws.*

Modules installed

(10 modules)

Power inlet on 

the GP10/GP20/GX60 (Power

inret type)

Power switch

Recording stopped

Recording in progress

MENU key

Browse tab

Set the date and time*.

Start measuring/recording.

Configure input and functions.

Common menu tab

To open, push the front door down and pull it toward you.

or

1

2

3

M3 screw

terminal

GX90XA

Analog input

 module

GX90XD

Digital input 

module

GX90YD

Digital output 

module

Clamp

terminal

M3 screw

terminal

M3 screw

terminal

Clamp

terminal

To prevent electric shock when 

wiring, make sure that the power 

supply is turned off.

* Recommended tightening 

  torque: 0.6 N•m

Install an expansion module (GX90EX) into the GX/GP.

1

GX60 

address setting

2

Connect the LAN cable bteween GX/GP and  GX60.

3

GX10/GP10 : Slot 2

GX20/GP20 : Slot 9

Setting switch

(DIP switch

GX90EX

GX90EX

GX60

Ex GX/GP

GX60

Connect an GX60

To connect an GX60.

First Step Guide 

(IM 04L51B01-02EN)

“Installation and Wiring”

Ex GX/GP

GX90WD

Digital input/

output module

M3 screw

terminal

9

GX90XP

Pulse input

module

M3 screw

terminal

Clamp

terminal

* If you need to set the 

time zone or DST (Daylight 

Saving Time) or both, do 

so before setting the date 

and time.

Reviews: