background image

Technical

Information

Data Acquisition System

Introduction to the Various 

Features of the GM

TI 04L55B01-01EN

TI 04L55B01-01EN

©Copyright Nov. 17 2014

4th Edition July 9 2018

Summary of Contents for SMARTDAC+ GM

Page 1: ...Technical Information Data Acquisition System Introduction to the Various Features of the GM TI 04L55B01 01EN TI 04L55B01 01EN Copyright Nov 17 2014 4th Edition July 9 2018...

Page 2: ...Blank Page...

Page 3: ...3 1 Basic Functions 3 1 3 1 1 Measurement 3 1 3 1 2 Recording 3 7 3 1 3 Output 3 11 3 1 4 Storage 3 12 3 1 5 Display Web browser 3 13 3 2 Various Functions 3 15 3 2 1 Alarm Function 3 15 3 2 2 Event A...

Page 4: ...3 13 Measurement Setting Server Function 3 46 3 3 14 Advanced security function AS option 3 46 3 3 15 Multi batch Function BT option 3 47 3 3 16 AEROSPACE HEAT TREATMENT AH option 3 48 3 3 17 OPC UA S...

Page 5: ...and functions If you find any inaccuracies or errors in this document please contact Yokogawa Any copy or reproduction of the content of this document in whole or in part without permission is prohib...

Page 6: ...itions and reductions Measurement on up to 420 channels Easy installation and reduction of modules with slide locks l Easy access from Web browser Hardware configuration Real time monitoring l Mobile...

Page 7: ...ure the following types of inputs The supported input types vary depending on the module For details on the various input types see section 3 1 1 Measurement Input Type DC voltage DCV Thermocouple TC...

Page 8: ...V 60mV 0 01 of rdg 5 V 6V 1 5V 0 01 of reading 2 mV TC R S 1 1 C B 1 5 C K 200 0 to 1370 0 C 0 01 of rdg 0 2 C for 0 0 to 1370 0 C 0 15 of rdg 0 2 C for 200 0 to 0 0 C K 200 0 to 500 0 C 0 2 C for 0 0...

Page 9: ...ent data l Data types Based on the sampled measurement values the GM can recorded two types of measurement data event data and display data the data type depends on the GM settings Measurement data is...

Page 10: ...tor data over a wide area You do not need to use a dedicated software application PC View on a Web browser Control operation configure Ethernet GM Web screen example n Configuration and Operation You...

Page 11: ...nd print them You can also calculate statistics on a specified set of data and convert data to ASCII and Excel formats l IP Address Configurator This software is used to set the GM10 s IP address subn...

Page 12: ...WT Bluetooth Tablet Single unit system Alarm output FAIL status output Manual DO Analog output Remote input Signal input Signal output DO DI Alarm output DI RTD TC DCV mA Pulse A Control input Control...

Page 13: ...odules Microwave oven Electromagnetic relay scanner Temperature in oven Ambient temperature Sub unit Main unit Noise l Performance evaluation testing of washing machines The GM is used to acquire rota...

Page 14: ...sting The GM acquires various types of data such as air temperature water temperature rotation air volume exhaust gas in tests performed on engine test benches Long term data acquisition is possible s...

Page 15: ...hernet Sub unit Main unit Web browser l Air conditioning monitoring in pharmaceutical labs and warehouses The GM is used to acquire and monitor the temperature humidity and the like in storage rooms f...

Page 16: ...Acquiring and monitoring of process data is easy with Data Logging Software GA10 Temperature Transfer speed Bubbles Photosensitizing agent volume Humidity Ethernet GA10 Film l Temperature distribution...

Page 17: ...ixed Only one module in a system Power Supply Module GM90PS Power switch Power inlet or terminal M4 A module for supplying power to the unit Supply voltage 100 240 V AC 12 28 V DC Input output Module...

Page 18: ...sal H0 4 1 ms High speed universal 4 wire RTD resistanse 6 100 ms SSR 4 wire RTD 2 2 Flexible Support for Channel Additions and Reductions YOKOGAWA s original block structure patented l Modules can be...

Page 19: ...connections can extend up to 100 m total Less wiring is possible by distribution such as when measurement locations are separated far apart Main unit LAN cable Sub unit The main unit and sub units are...

Page 20: ...b unit When a sub unit is connected Multi unit system Main unit Single unit system Data acquisition module n Sub Unit A sub unit is connected to the main unit An expansion module GX90EX is linked to c...

Page 21: ...esktop Legs for desktop installation n DIN Rail Mounting The GM can be mounted easily on a DIN rail using the latches on the rear of the module base Latches for DIN rail mounting n Wall Mounting The G...

Page 22: ...rsal individual A D type H0 4 4 wire RTD resistor scanner type R1 6 Digital input GX90XD 16 Pulse input GX90XP 10 Digital output GX90YD 6 Digital input output GX90WD Input 8 Output 6 Analog output GX9...

Page 23: ...nto temperature values Input value Measured value 10 V 0 V 300 C 100 C l Delta The measured value of the channel is set to the difference with respect to the measured value of the reference channel Fo...

Page 24: ...ation Up to 12 correction points can be specified Linearizer approximation Corrects input values using characteristics specified with segments to derive output values Output value Measured value Input...

Page 25: ...s are present in the system the shortest scan interval that you can set is the shortest scan interval of the slowest module A D conversion Scan interval 1 23 Measured value Input signal Shortest scan...

Page 26: ...to 16 67 ms Common Sets the integration time to 16 67 ms 20 ms 36 67 ms or 100 ms Integration time and scan interval by module Type Integration Time Scan Interval 10ch mode 2ch mode Universal DC curr...

Page 27: ...ange Percentage of the specified span width Lower Limit of Burnout 20 0 to 5 0 Upper limit of burnout 105 0 to 120 0 n Operation Modes of Modules l AI modules 2ch mode and 10ch or 6ch mode are availab...

Page 28: ...ypes Explanation Event data Measurement data that is recorded at the specified recording interval There are two modes One mode starts recording when a trigger occurs The other mode records at all time...

Page 29: ...ple is not retained but because the maximum and minimum data values are recorded display data expresses the fluctuation range in each recording interval In addition because the number of data values c...

Page 30: ...The GM enters the trigger wait state when you start recording After a trigger event occurs the GM will record data for the specified time data length and stop From this point the GM will not record ev...

Page 31: ...y the channels assigned to recording channels are recorded as measurement data You can select the channels to record from AI channels DI channels pulse input channels DO channels math channels MT opti...

Page 32: ...alarm assigned to a measurement channel occurs a relay signal is output from the DO channel that the alarm output is assigned to Alarm occurrence Relay output l Manual output DO channels can be turne...

Page 33: ...New l Media FIFO Save Operation Up to the most recent 1000 files are retained If the number of files in the save destination directory exceeds 1000 the number of files is held at 1000 by deleting old...

Page 34: ...icated software application 3 1 5 Display Web browser Real time monitoring of measurement data is possible from a Web browser You do not need to use a special software application You can also configu...

Page 35: ...n free messages 1 to 10 Auto message When the GM recovers from a power failure during recording a fixed message is written n Configuration You can configure the GM from a Web browser When a configurat...

Page 36: ...asured values over a certain interval is greater than or equal to the specified value Change in the measured value Measured value Time Interval t2 t1 T2 T1 t1 t2 Amount of change in the setting T2 T1...

Page 37: ...l H L T t R r h l Measured value n Hysteresis You can furnish an offset between the value used to activate and release alarms This is fixed at 0 for the DI range Example H If you set the alarm value o...

Page 38: ...deactivated can be set to 500 ms 1 s or 2 s Relays set to Reflash will operate using OR and Nonhold settings l Energize or De energize Operation You can select whether the alarm output relay is energi...

Page 39: ...n ACK Relay action on ACK occurrence Activated Deactivated Activated Deactivated Activated Deactivated release Activated Deactivated Display Alarm Hold Non hold DO output relay Hold Non hold Hold Non...

Page 40: ...ding You can specify this when the GM is configured to event data Message writing Writes a message Specify the message number and the message write destination Set the destination to all groups or spe...

Page 41: ...elay On Off1 2 Internal Switch2 Internal switch On Off1 2 1 When the operation mode is rising falling edge 2 Action can be set to Relay output Relay On Off Internal switch or Internal switch On Off on...

Page 42: ...specified loops to manual when the input changes from on to off Remote local switch specified loop Switches the control operation of specified loops to remote when the input changes from off to on Sw...

Page 43: ...ttern Stops the operation of the specified program pattern of the specified loop when the input changes from on to off Program pattern number switch binary BCD selection Switches the program pattern n...

Page 44: ...omment l Batch Information Item Explanation Batch No Up to 32 characters A a 1 Lot No Lot numbers can be set to not use 4 digits 6 digits or 8 digits Comments 1 to 3 Up to 50 characters each A a 1 You...

Page 45: ...Otherwise the result is 0 NE or a NE b or a b The computed result is 1 when a is not equal to b Otherwise the result is 0 Logical operator AND e1ANDe2 If the two data values e1 and e2 are both non zer...

Page 46: ...itional expression a b c a b c If the value of expression a is true expression b is executed otherwise expression c is executed Remainder extracting operation MOD a MOD b Determines the remainder when...

Page 47: ...reate a variety of report files from the measured data of I O channels math channels and communication channels You can set up to 60 report channels You can set up to five computation types You can se...

Page 48: ...y create custom report files Load a report template file that you have created into the GM internal memory The GM will automatically create report files using the report template file Report template...

Page 49: ...sers administrators and users can log in to the GM to perform monitoring and operation l User Levels User Level Explanation Administrator Admin An administrator can perform all GM operations User Auth...

Page 50: ...ext field writing Alarm ACK Restricts alarm ACK operations Communication Restricts the operations to start stop and test mail test FTP get and release network information test printer output manually...

Page 51: ...utput when an error occurs in the internal memory or external storage medium Error in the internal memory Error in the external storage media Measurement error A relay signal is output when a measurem...

Page 52: ...0 Interval 10 minutes The timer expires at 0 hour 0 hour 10 min 0 hour 20 min 23 hour 40 min and 23 hour 50 min For example if the timer is set at 9 hour 36 min the timer expires at 09 hour 40 min 09...

Page 53: ...and the decimal digits of the voltage representing the mantissa l Input That Is Linear on a Logarithmic Scale This is referred to as Log linear input Log linear input is input in which the voltage val...

Page 54: ...ction to correct the GM input values with linear approximation Conceptual diagram The pressure scale is mapped to an input scale that has been multiplied by a constant number to derive the output scal...

Page 55: ...as retrieving directory and file lists from the external storage medium SD card of the GM and transferring and deleting files In addition you can also retrieve the directory or file list and transfer...

Page 56: ...created in the external storage medium of the GM can be automatically transferred when they are created Data file FTP server Primary Secondary Ethernet Destination FTP server information Transfer log...

Page 57: ...cluded is the instantaneous value at the time of the e mail transmission Report Report notification An e mail is transmitted when a report is created Periodic Scheduled notification An e mail is trans...

Page 58: ...e set on communication channels PC Modbus device WT Communication channel GM10 1 C001 to C300 GM10 2 C001 to C500 Data l Watchdog Timer Function Data may fail to be updated due to Modbus or other comm...

Page 59: ...annel MC option data Write data to communication channels Start and stop recording write messages and perform other operations Load the recording start stop condition message strings and other types o...

Page 60: ...ent Ethernet GM Command Input register Hold register Read Write Read 3XXXXX 4XXXXX Write Read Read Server device Winternal register GM l Number of Commands Type Number of Commands GM10 1 100 GM10 2 20...

Page 61: ...spoofing by other devices and data eavesdropping n Supported Servers HTTP server and FTP server are supported l HTTP Server Function A certificate is saved in the internal memory in advance When a PC...

Page 62: ...received from the server to the one in the internal memory Encrypted e mail is sent to the server Ethernet Encryption Certificate SMTP server Email Trusted certificate n Trusted Certificate Electroni...

Page 63: ...format EB Sets the byte output order l ESC T Command If a Esc T command is received time synchronized measured value and math value are held in the local buffer until the next Esc T command is receiv...

Page 64: ...Starts message printing IM Sets the interrupt mask SM Sets the auxiliary mask l Handling of Commands for Functions Not Available on the GM If a command or parameter for a function not available on the...

Page 65: ...communications with these PLCs n GM Functions The GM provides the following functions Participate in an EtherNet IP network as an Adapter Server Communicate with new and old Allen Bradley PLCs such as...

Page 66: ...ORE STORE SET POWER Server 2 Measurement value Computation value l Connectable Models and Options Maker Models Option Description Yokogawa Meter Instrument WT300 WT330 G5 Harmonics Measurement WT500 G...

Page 67: ...ting Server Function Dedicated commands can be used to configure the GM acquire data and so on Supported interfaces Ethernet USB RS 422 485 C3 Bluetooth C8 3 3 14 Advanced security function AS option...

Page 68: ...l Main Specifications Item Specification Number of multi batches GM10 1 6 max GM10 2 12 max Batch single operation Memory start stop math reset message writing Batch overview operation Computation sta...

Page 69: ...and Renotification is set to 8h Notification screen display start Calibration due date Notification screen appears Renotification Renotification Renotification Renotification 00 00 08 00 16 00 00 00...

Page 70: ...g UA Binary Protocol OPC UATCP Maximum number of connections 3 sessions Profile Micro Embedded Device Server Language English Security Type None Encryption None Login Anonymous Username Data acquisiti...

Page 71: ...Items SetMonitoringMode Subscription CreateSubscription ModifySubscription DeleteSubscriptions Publish Republish SetPublishingMode l Data Structure Device GM10 1J IP Address or hostname Object IO Chan...

Page 72: ...e conversion I O channel Math channel Communication channel SLMP Client GX GP Ehernet GM l Communicable internal data Internal data Device code Special relay SM Special register SD Input X Output Y In...

Page 73: ...uts two control outputs eight digital inputs and eight digital outputs In addition to single loop control cascade control and loop control with PV switching are possible For the control output you can...

Page 74: ...Add Pulse input module Multi batch function Aerospace heat treatment OPC UA server SLMP communication Mitsubishi PLC June 2017 3rd Edition Supported Release 4 of the Data Acquisition System GM July 20...

Reviews: