Hardware Setup Guide

Summary of Contents for DME32

Page 1: ...Hardware Setup Guide...

Page 2: ...ety of analog and digital formats It is possible to mix analog and digital cards in a single DME32 unit There are no restrictions to any combination of MY cards used together in a single unit MY8 AD E...

Page 3: ...one digital MY Card for its outputs DA824 Eight 24 bit Line Level Outputs on XLR and 1 4 TRS Selectable maximum output levels of 4 15 18 and 24db by internal DIP switches independently per channel Thi...

Page 4: ...n a logical choice for cards would be 1 MY4 AD and 2 MY4 DA There is no particular order you have to follow for putting the cards in the slots Each card slot corresponds to a specific input and output...

Page 5: ...or 8 Channels of Digital I O Use one digital MY8 card For 16 Channels of Digital I O Use two digital MY8 Cards For 24 Channels of Digital I O Use three digital MY8 Cards For 32 Channels of Digital I O...

Page 6: ...E or MY8 AT One card goes into each DME32 AD824 and DA824 16 Channels of Analog I O 2 AD824 2 DA824 6 MY8 AE or MY8 AT Two cards go into DME32 and one card into each AD824 and DA824 24 Channels of Ana...

Page 7: ...Wordclock signal is sent to the AD824 units in either the AES EBU or ADAT connection examples Wordclock BNC Cables must be run from the DME32 to the AD824 Please see Chapter 13 page 227 of the DME32...

Page 8: ...use this card with a DME32 and AD824 DA824 configuration a split AES EBU cable must be created You must use shielded 110 ohm twisted pair AES cable and 25 pin Male D sub connector on each end Up to 20...

Page 9: ...tput 7 8 Twisted Pairs Signal Description 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 5 6 7 8 10 12 13 18 19 20 21 1 2 3 4 14 15 16 17 22 23 24 25 D sub 1 DME32 D sub 2 Input D s...

Page 10: ...m the DME32 via RS 422 Gain Control and Phantom Power On Off can be manipulated and recalled by the DME32 In order to do this RS 422 Cables need to be run from the DME32 to the first AD824 and then da...

Page 11: ...d into The ID numbers should be noted and will be used by the software to address them This is the pin configuration for the RS 422 Cable Dsub 1 9 pin Dsub Female Dsub 2 9 pin Dsub Female 2 3 4 5 6 7...

Page 12: ...ES EBU Cable AD824 DME32 DA824 AD824 DA824 A 16 Channel I O sytem using AES EBU transmission An RS 422 connection is also made to remotely control the AD824 functions Up to 200 meters of separation be...