background image

Instruktionsmanual 

Sida 

2

Inbyggnad / monterings anvisningar

Skötselråd / underhålls instruktioner

Frågor & svar / felsökning

Instruction manual 

Page 

11 

Mounting / installation instructions

Maintenance / service instructions

Questions & answers / troubleshooting

Bedienungsanleitung

 

Seite 

19

Montage / installationsanleitungen

Wartung / serviceanleitungen

Fragen & antworten / störungsbeseitigung

P8 Multikoppling

P8 Multi-Coupling

Multikupplung P8

GB

D

S

CEJN AB 

Hasslumsvägen 33 

S-6541 25 Skövde, Sweden

XPND

Box 2921, 187 29 Täby. Besöksadress: Kemistvägen 12

Tel: 08-756 62 00, Fax: 08-758 07 35. E-post: [email protected]

Summary of Contents for P8

Page 1: ...rvice instructions Questions answers troubleshooting Bedienungsanleitung Seite 19 Montage installationsanleitungen Wartung serviceanleitungen Fragen antworten st rungsbeseitigung P8 Multikoppling P8 M...

Page 2: ...latta 16 933 0097 4 2 3 Rampplatta 16 933 0098 5 3 HANDHAVANDE 6 3 1 N r du h mtar bussen 6 3 2 N r du l mnar bussen 7 4 FR GOR SVAR FELS KNING 8 5 UNDERH LL SK TSEL 9 6 RESERVDELSLISTA 10 INNEH LLSF...

Page 3: ...ringsinstruktion och s kerhetsf reskrifter g llande el kontakten h nvisas till el kontaktens egen instruktion MA202 def Monteringsanvisning g llade induktionsgivaren terfinns p dess f rpackning Innan...

Page 4: ...m 3 4 Startsp rrgivare som r en induktionsgivare typ PNP typ nomally closed levereras l s och skall monteras p ett avst nd av 11 1 mm fr n pl ten enl skiss Tryckluft i nippel som r av typen CEJN 320 m...

Page 5: ...der plattan Viktigt att h let i bussen r minst 320x155 mm 2 3 Rampplatta 16 933 0098 Rampplattan monteras p ett fast underlag med god tkomlighet F stpunkterna r de samma som f r bussplattan 16 933 009...

Page 6: ...n bussen i de svarta handtagen Koppla in plattan i parkeringsl get p rampen p rampen genom att TRYCKA IN den i rampplattan hj lp samtidigt till att pressa ihop plattorna med fingrarna genom att h lla...

Page 7: ...dor DRA UT slangplattan fr n rampen i de svarta handtagen Koppla in slangplattan i bussen genom att styra in pinnen i mitth let och TRYCK IN slangplattan hj lp samtidigt till att pressa ihop plattorna...

Page 8: ...n ringar en 5 mm och en 2 mm kontrollera att denna dessa r korrekt monterade Startsp rren fungerar inte Svar Elkablarna r av Svar Startsp rrgivare r monterad f r l ngt in se installation bussplatta Sl...

Page 9: ...T nk p att inte verdriva fettm ngden d detta kan drar till sig och binda smuts Sm rjnippel med fettspruta Rymmer 200 g fett CEJN nr 16 933 0100 Ett tryck r tillr ckligt Se mer information i separat in...

Page 10: ...ontakt 06 933 4100 Bakdel elkontakt buss och slangplatta 06 933 0700 Styrbussning buss och rampplatta 06 933 0806 Mutter M22 till styrbussning Rampplatta 16 933 0098 06 933 2101 Elkontakt rampplatta G...

Page 11: ...13 2 3 Ramp plate 16 933 0098 14 3 OPERATION 15 3 1 When picking up the bus 15 3 2 When leaving the bus 16 4 QUESTIONS ANSWERS TROUBLESHOOTING 17 5 SERVICING MAINTENANCE 18 6 SPARE PARTS LIST 19 TABLE...

Page 12: ...elating to the electrics connector please refer to the instructions issued by the connector manufacturer Multi Contact MA202 def Installation instructions for the inductive sensor are printed on the p...

Page 13: ...or which is a PNP type normally closed inductive sensor is supplied separately and must be fitted at a distance of 11 1 mm from the plate as illustrated in the diagram Compressed air goes to a CEJN 32...

Page 14: ...below the plate Important the hole in the bus must be at least 320x155 mm 2 3 Ramp plate 16 933 0098 Install the ramp plate on a firm base which allows good access The attachment points are the same a...

Page 15: ...the black handles Attach the hose plate in its parked position on the ramp by PUSHING it INTO the ramp plate This is best achieved by pressing the plates together with the fingers while holding onto...

Page 16: ...OUT the hose plate from the ramp using the black handles Attach the hose plate to the bus by guiding the pin into the centre hole and PUSHING the hose plate IN This is best achieved by pressing the p...

Page 17: ...Check that the spacer s is are correctly fitted The starter inhibitor is not working Answer The electrical cables have become disconnected Answer The starter inhibitor sensor has been fitted too far i...

Page 18: ...is can result in build up of dirt Grease nipple with grease gun Takes 200 g of grease CEJN No 16 933 0100 One press is sufficient For more information see the separate instructions Grease for grease g...

Page 19: ...rics connector 06 933 4100 Rear assembly electrics connector bus and hose plate 06 933 0700 Guide bushing bus and ramp plate 06 933 0806 Nut M22 for guide bushing Ramp plate 16 933 0098 06 933 2101 El...

Page 20: ...0097 22 2 3 Rampenplatte 16 933 0098 23 3 VERWENDUNG 24 3 1 Beim Holen des Busses 24 3 2 Beim Zur ckstellen des Busses 25 4 FRAGEN UND ANTWORTEN FEHLERSUCHE 26 5 WARTUNG UND PFLEGE 27 6 ERSATZTEILLIST...

Page 21: ...rom genutzt Montage und Sicherheitshinweise f r den elektrischen Anschluss entnehmen Sie dem separaten Dokument MA202 def Montagehinweise f r den Induktionsgeber sind auf dessen Verpackung aufgedruckt...

Page 22: ...eber entspricht einem Induktionsgeber vom Typ PNP ffnungskontakt Er wird lose geliefert und ist in einem Abstand von 11 1 mm vom Blech anzubringen siehe Skizze Die Druckluftversorgung erfolgt ber den...

Page 23: ...s min destens 320x155 mm gro sein 2 3 Rampenplatte 16 933 0098 Die Rampenplatte ist auf einer stabilen Unterlage zu montieren die gut erreichbar ist Es gelten dieselben Befestigungspunkte wie f r die...

Page 24: ...s Bringen Sie die Platte an der Rampe in die Parkstellung indem Sie sie in die Rampenplatte HINEINBEWEGEN Dr cken Sie zur Unterst tzung gleichzeitig mit den Fingern die Platten zusammen indem Sie die...

Page 25: ...lauchplatte an den schwarzen Griffen von der Rampe heraus Verbinden Sie die Schlauchplatte im Bus indem Sie den Stift zum mittleren Loch bewegen und die Schlauchplatte HINEIN BEWEGEN Dr cken Sie zur U...

Page 26: ...g korrekt montiert ist bzw die Ringe korrekt mon tiert sind Die Startsperre funktioniert nicht Antwort Die Stromkabel sind nicht angeschlossen Antwort Der Startsperrengeber ist zu weit innen montiert...

Page 27: ...t auf Andernfalls entstehen Fettansammlungen die Schmutz binden k nnen Schmiernippel mit Fettspritze Fasst 200 g Schmierfett CEJN Nr 16 933 0100 Eine Bet tigung gen gt Weitere Informationen entnehmen...

Page 28: ...stoffgeh use elektrischer Anschluss 06 933 4100 Hinterteil elektrischer Anschluss Bus und Schlauchplatte 06 933 0700 F hrungsbuchse Bus und Rampenplatte 06 933 0806 M22 Mutter f r F hrungsbuchse Rampe...

Reviews: