Getting Started

What’s Included

• One (1) YOUniversal Electronic 3D Eyewear
• One (1) Glasses Case
• One (1) Multifunction port to USB cable
• One (1) Microfiber Cloth
• Two (2) Nosepieces

Compatibility

XPAND YOUniversal 3D glasses are compatible with all major brands of 3D LCD TVs, 3D 
DLP TVs and 3D Plasma TVs that use IR synchronisation with 3D eyewear (glasses won’t 
work with TVs, laptops and projectors that use RF for 3D sync signal or passive displays). 
For YOUniversal 3D Glasses to work with TVs that use radio frequency for 3D sync signal, 
XPAND’s  RF  Dongle  (radio  frequency  extension)  is  necessary.  It  is  available  as  extra 
accessory.
Additionally  XPAND  equipped  cinemas  and  some  3D  capable  personal  computers  are 
supported as well. 

Warranty

1-year limited product repair / replacement warranty. For detailed warranty statement visit 
www.xpand.me/youniversal/

Functionality

Glasses Overview

(1)  Button  (ON,  OFF,  IR  protocol 
selection)
(2) Battery LED light

(3) “X” LED light

Turning On/Off Your Glasses 

• Step 1 ON: Press button (1) once
• Step 2 “X” LED light (3) will ramp from off to bright
• Step 3 OFF: Press button (1) once
• Step 4 “X” LED light (3) will ramp from bright to off
Glasses also automatically turn off if no valid sync is detected for 5 minutes.

Set Glasses To Operate With Your Device

• Step 1 XPAND YOUniversal 3D glasses support an automatic IR protocol detection. To 

start the auto detect process, press and hold the button (1) for 3 seconds.

• Step 2 »X« LED (3) will blink until auto detection is completed. Procedure may take up to 

one minute. 

• Step 3 If auto detection was completed successfully, sit back and enjoy your program. The 

glasses will store detected IR protocol in memory and will always start up in this mode the 
next time you turn the glasses on.

Select Device Manually

• Step 1 Press and hold the button (1) for 3 seconds. Glasses will enter auto detect mode.
• Step 2 Press and hold the button (1) for 6 seconds.
• Step 3 “X” LED light (3) will blink once, corresponding to a Samsung TV (See supported 

IR protocol codes below).

• Step 4 Press button once to step through the other device options until you get to desired 

IR protocol.

• Step 5 If you have selected the correct IR protocol then sit back and enjoy your program. 

Within 30 seconds the glasses will exit the programming mode and store your selection in 
memory. The glasses will always start up in this mode the next time you turn the glasses 
on.

Supported IR Protocol Codes

• Samsung* or Mitsubishi** 

1 Blink

• LG* 

2 Blinks

• Sony** 

3 Blinks

• Panasonic or M-3DI devices 

4 Blinks

• Philips* or HP or JVC 

5 Blinks

• XPAND Emitter 

6 Blinks

• Nvidia 

7 Blinks

• Vizio 

8 Blinks

• Bang and Olufsen 

9 Blinks

• Sharp 

10 Blinks

• Acer 

11 Blinks 

• XPAND Cinema 

(entered automatically whenever sync is present)

* LG 2011 TV models are not supported, whereas Samsung 2011 TV models require XPAND RF 
Dongle.
** Some TV models require the use of external emitter; please check with your TV manufacturer.

Set Glasses for use in XPAND Equipped Cinemas

Simply turn the glasses on and XPAND Cinema mode will be entered automatically. 

Indicating Battery State

If red battery LED (2) flashes every couple of seconds, battery level is low. LED indicates low 
battery state only when glasses are turned on. 
Charging is indicated with orange battery LED (2) flashing every second.
When battery is fully charged, battery LED (2) turns green.

Charging the Battery

To 

charge

 glasses, plug the multifunction port to USB cable to multifunction port on one 

side and in computer or other USB device capable of supplying power (wall charger) on 
the other. Orange battery LED (2) will flash while charging. When battery is fully charged, 
battery LED (2) is illuminated green until power supply is removed from the glasses. 
Please make sure the battery is fully charged before first use of the glasses.

Connecting Glasses to a PC

By connecting glasses to a PC and using the XPAND PC application, one can easily change 
desired IR protocol, custom set shutters timings and upgrade glasses firmware. To access 
these  settings,  XPAND  PC  application  has  to  be  installed  on  the  PC.  The  app  can  be 
downloaded from www.xpand.me/youniversal/.

To select desired IR protocol

, connect multifunction port to USB cable to the 

glasses and PC. Run XPAND PC application. Select protocol from drop down menu. Unplug 
multifunction port to USB cable from the glasses. The glasses are now set.

To change advanced shutter timings

, click on “Show advanced options”. In 

XPAND PC application click and drag two slides corresponding to “open delay” and “close 
delay”  and  set  desired  timings.  To  discard  any  changes  made  click  “Reset  to  default” 
button. Advanced option menu is closed with click on “Hide advanced options”. 

To upgrade firmware

 on the glasses turn glasses on and plug multifunction port to 

USB cable to the PC and on the other end to the glasses. Launch the XPAND PC application 
and click on the “Application update available” or “check for update” button. Ensure that 
the PC is connected to the Internet. The glasses will be updated from server automatically 
on confirming that you want to update glasses with newest firmware. If you want to update 
from file, click “No” in the “Download firmware” dialog box and then choose the desired file. 
Update takes some time. When the operation is complete, a dialog box confirms successful 
update. Do not unplug multifunction port to USB cable during update process!

Eyewear Specifications

Product Weight: 1.55 oz (46 g) - small and medium size; 1.66 oz (47g) - large size
Power Supply: Battery type: Rechargeable Lithium-ion Polymer 3.7Vdc / 0.135A
Operating Temperature: 5 ºC (41 ºF) – 40 ºC (104 ºF)